| Model | Nominal Size | Max Pressure | Max Flow | Pressure Compensator | Check Valve |
|---|---|---|---|---|---|
| 2FRM6 | DN6 | 31.5 MPa | 25 L/min | B Type (Standard) | Optional (M/R) |
| 2FRM5 Valve | DN5 | 21.0 MPa | 15 L/min | B Type | Optional (M/R) |
| 2FRM10/16 Valve | DN10/16 | 31.5 MPa | 160 L/min | B Type | Optional (M/R) |
Data source: Technical data table.
Text-based mounting parameters for the 2FRM6 valve:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-03 (CETOP 3) |
| Bolt Pattern | 4 x M5 threaded holes (40.5 x 40.5 mm) |
| Port Connections | A, B, P (Requires O-ring 9.25 x 1.78 mm) |
| Body Width | 60 mm |
| Height | 170 mm (including adjustment knob) |
| Weight | Approx. 1.3 kg |
The 2FRM6 uses a pressure compensator to maintain a constant pressure drop across the throttle orifice. This ensures the flow rate remains stable even if the load pressure or oil temperature changes.
The 2FRM6 model code is built as follows: `2FRM6` + `A/B` + `Flow Code` + `20` + `M/R` + `Options`.
Example: `2FRM6B6Q20R3` = Standard pressure compensator, 6 L/min flow, with check valve, lockable scale knob.
Replacing an old flow control valve? Check:
Used in machine tools, plastic injection molding machines, and metallurgical equipment to ensure precise and stable actuator speeds.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Not sure about the flow code or whether you need the A type for external closing? Contact our engineers with your system requirements.
Q: What is the maximum flow rate for the 2FRM6 valve?
A: The 2FRM6 supports a maximum flow rate of 25 L/min.
Q: What is the difference between A and B types?
A: The A type features an external closing of the pressure compensator, which prevents flow overshoot during startup. The B type is the standard version.
Q: What is the function of the Z4S rectifier plate?
A: The Z4S rectifier plate can be mounted under the 2FRM valve to control flow in both directions (A to B and B to A).
Q: Can I replace the adjustment knob?
A: Yes, we supply replacement knobs with or without the locking mechanism.
For 2FRM6 flow control valve selection and spare parts, contact HYRIG: info@hyrig.com