| Model | Nominal Size | Max Flow (L/min) | Pilot Source | Max Pressure |
|---|---|---|---|---|
| 4WRZ25 | DN25 | 870 | Internal (Pilot Valve) | 35 MPa |
| 4WRH25 | DN25 | 870 | External (X port) | 35 MPa |
| 4WRZ16 Valve | DN16 | 460 | Internal (Pilot Valve) | 35 MPa |
| 4WRZ32 Valve | DN32 | 1600 | Internal (Pilot Valve) | 35 MPa |
Data source: Technical data table.
Mounting parameters for the DN25 size:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-08 (CETOP 8) |
| Bolt Pattern | 6 x M12 threaded holes |
| Port Connections | A, B, P, T, X, Y (O-ring sizes vary) |
| Weight | 17.5 kg (2-position) / 18.2 kg (3-position) |
The main spool is controlled by the pressure difference created by the pilot valve. The 4WRZ uses an integrated 3DREP6 proportional pressure reducing valve as a pilot. The 4WRH has no pilot valve and requires an external pilot pressure (0.4 to 2.5 MPa) connected to ports X and Y.
`4WRZ` or `4WRH` + `25` + `Spool Type` + `30` + `Nominal Flow` + `Pilot Oil (E/ET/T)` + `Voltage`.
Replacing an old valve? Check:
Used in heavy machinery, metallurgy, and large presses for high-flow, precise directional control.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help choosing between WRZ and WRH, or configuring the control oil? Contact our engineers with your system schematic.
Q: What is the maximum flow rate for the DN25 size?
A: The DN25 size supports a maximum flow rate of 870 L/min.
Q: What pilot pressure is required for the 4WRH25?
A: The 4WRH25 requires a pilot pressure between 0.4 to 2.5 MPa at the X port.
Q: What is the mounting interface for the DN25 valve?
A: The DN25 valve uses the ISO 4401-08 (CETOP 8) mounting interface with 6 x M12 bolt holes.
For 4WRZ/4WRH DN25 proportional directional valve selection and spare parts, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.