Our API 610 A8 redistillation column side draw pumps are available in BB2, OH, and VS designs, specifically engineered for extracting C8+ aromatic side streams – containing primarily xylenes (approximately 1.9%) and ethylbenzene (0.05%) – from A8 redistillation columns in aromatics complexes. BB2 pumps with radially split between‑bearings construction are the preferred choice for reliable side draw duty, delivering stable flow with excellent rotor rigidity. OH pumps serve smaller extraction services, while VS pumps handle low‑NPSH suction. Built with carbon steel, stainless, and corrosion‑resistant alloys. Fully API 610/ISO 13709 and NACE compliant for long‑life, reliable service.

Conatct For Details
DetailReview(0)Additional

Our API 610 A8 redistillation column side draw pumps are heavy‑duty centrifugal pumps engineered specifically for extracting C8+ aromatic side streams from A8 redistillation columns in aromatics complexes and petrochemical plants. The A8 redistillation column is a key unit in aromatics production that further purifies C8 aromatic streams, typically following the A8 stripper, to produce high‑quality mixed xylenes and ethylbenzene products. The side draw product is a C8+ aromatic stream with a typical composition of approximately 1.87% xylenes, 0.05% ethylbenzene, and predominantly heavier C9+ aromatic components. This side stream serves as a valuable feedstock for downstream heavy aromatics processing, solvent production, or fuel blending.

The side draw extraction point is typically located at an intermediate tray of the redistillation column. This fluid is characterized by elevated temperatures (typically 170‑220°C), moderate volatility, low viscosity, and often contains trace sulfur compounds and heavy aromatic components. Pumps for this service demand robust construction, reliable sealing, stable flow control, and excellent low NPSH performance. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for continuous, reliable, and safe operation. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – with the BB2 type (radially split, single‑stage or two‑stage) being the preferred choice for main side draw extraction duties due to its superior rotor stability and thermal expansion management.

API 610 Classifications for A8 Redistillation Side Draw Duties

  • BB2 – Between Bearings Pumps (Preferred for Main Side Draw Extraction)
    For the main side stream extraction from the A8 redistillation column, the BB2 subtype (radially split, single‑stage or two‑stage, between‑bearings) is the preferred configuration. The radially split casing allows the pump to expand evenly with temperature without distorting internal clearances – critical when handling streams with significant temperature differentials. The between‑bearings arrangement provides exceptional rotor rigidity, minimising shaft deflection and vibration. Single‑stage BB2 pumps handle moderate flows (30‑800 m³/h) at heads up to 150 metres, while two‑stage variants cover higher head requirements. Centreline support accommodates thermal expansion.

  • OH – Overhung Pumps
    In redistillation column systems, OH pumps are typically employed for smaller extraction duties, booster services, or auxiliary side draw points where flows and pressures are lower. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes provide compact, cost‑effective solutions for auxiliary roles. Centreline mounting ensures thermal expansion does not misalign the pump and driver.

  • VS – Vertically Suspended Pumps
    VS pumps are used where the column side draw tray has very low NPSH or where floor space is limited. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the first‑stage impeller below the liquid level, providing excellent NPSH performance. They are also used in closed‑loop systems where floor space is limited.

Key Performance & Design Features (BB2 Focus)

  • Temperature Capability – Engineered for C8+ aromatic temperatures up to 220°C (428°F), with appropriate material selection and thermal expansion allowances.

  • Flow & Head – Capacities from 20 m³/h to over 800 m³/h; heads typically from 30 to 150 metres.

  • Casing Design – Radially split casing with centreline support to accommodate thermal expansion without distortion. Heavy‑wall construction for pressure integrity at elevated temperatures.

  • Materials – Wetted parts in carbon steel (ASTM A216 WCB), chrome‑moly steels, or stainless steels (304, 316L) depending on service conditions. Full NACE MR0175/ISO 15156 compliance available for sour service.

  • Sealing – API 682 mechanical seals (single, dual, or tandem) with appropriate flush plans – typically Plan 11 (internal recirculation), Plan 32 (clean injected flush), or Plan 53 (pressurised dual seal) – to ensure seal integrity and prevent product leakage.

  • Bearing & Lubrication – Heavy‑duty sleeve or rolling element bearings with forced oil or oil mist lubrication; bearing temperature and vibration monitoring for predictive maintenance.

  • Impeller Options – Closed impellers for efficient handling; all dynamically balanced per API 610.

  • NPSH Performance – Optimised first‑stage impeller design for low NPSH requirements to handle side draw suction conditions.

  • Thermal Expansion – Adequate internal clearances, expansion joints, and flexible coupling designs to accommodate temperature gradients.

Typical Applications

  • C8+ aromatic side stream extraction from A8 redistillation columns

  • Heavy aromatic product transfer to storage or downstream processing

  • Side draw pumping in aromatics complexes and petrochemical plants

  • C9+ aromatic recovery in aromatics fractionation trains

Industries Served

  • Petrochemicals (aromatics production, heavy aromatics processing)

  • Oil refineries (catalytic reforming, aromatics complexes)

  • Chemical processing (C9+ aromatic separation)

Why Choose Our A8 Redistillation Side Draw Pumps?

With deep expertise in aromatic hydrocarbon handling and full API 610 compliance, we design and manufacture A8 redistillation column side draw pumps that deliver unmatched reliability, safety, and efficiency. Every pump undergoes rigorous hydrostatic testing, performance curve verification, mechanical running tests, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet the most stringent owner‑operator specifications. We offer customised hydraulic designs, material upgrades, and sealing arrangements tailored to your specific C8+ aromatic composition, temperature, and flow requirements. Our engineering support includes API 684 rotor dynamics, thermal expansion analysis, and NPSH margin studies to ensure seamless, long‑term operation in the most demanding aromatics fractionation services.

Contact Us

For technical datasheets, application engineering advice, or a project‑specific quotation, please contact us at:

info@hyrig.com

Trust our API 610 A8 redistillation column side draw pumps to deliver reliable C8+ aromatic side stream extraction for your aromatics production processes.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit