The Amine Circulation Pump is purpose‑built for lean amine (regenerated, low acid‑gas content) and rich amine (H₂S/CO₂‑loaded) services in natural gas sweetening, refinery hydrodesulfurization, and CCUS (carbon capture). All pumps fully comply with API 610 11th/12th edition – guaranteeing a minimum 3‑year uninterrupted operation and a design life of 20 years.
| Type | Construction | Best Application |
|---|---|---|
| OH2 | Overhung, centerline‑mounted, single‑stage | Medium head, low to moderate flow for amine circulation |
| BB3 | Axially split, multistage barrel casing | High head (up to 1,640 m), high‑pressure lean amine injection |
| VS4 | Vertical suspended, sump type | Sump or pit installation where floor space is limited |
Hydraulic range: Q = 7–1,600 m³/h, H = up to 1,640 m, T = –80°C to +200°C
Materials (API 610 Table H): 316L stainless steel (S‑8) as standard. Duplex / Super Duplex available for chloride‑containing amine.
Mechanical seals: API 682 dual pressurized seals with Plan 53B (barrier fluid > process pressure) – mandatory for rich amine to prevent H₂S emission. Seal faces: SiC/SiC; elastomers: Aflas®.
Shaft & bearings: Heavy‑duty shaft, L10 bearing life >40,000 hours.
Low NPSH: Inducer option for low NPSHa conditions.
| Parameter | Lean Amine Pump | Rich Amine Pump |
|---|---|---|
| Temperature | 70–120°C (higher) | 40–60°C |
| Corrosivity | Moderate (degradation products) | Higher (H₂S + CO₂ loaded) |
| Main concern | Thermal stability | Toxic gas containment |
| Recommended seal | Dual Plan 53A/53B | Dual Plan 53B (mandatory) |
Successfully replaced imported units in high‑sulfur gas plants (e.g., Puguang project, China) – 50% cost reduction and efficiency restored from 57.5% to >95%.
API 610 BB3 pumps in residue hydrotreating: discharge pressure 16.2 MPa, head 1,641 m, power 886 kW.
VS4 pumps widely used for amine sump transfer in refineries.
Full compliance – API 610 (OH2/BB3/VS4) + API 682 sealing systems.
Corrosion management – 316L wetted parts plus amine reclaimer integration to reduce heat‑stable salts.
Ease of maintenance – OH2 and BB3 designs allow rotor removal without disturbing pipework.
Long‑term reliability – Designed for 20‑year plant life with >3 years continuous duty.
Gas sweetening (amine treating units)
Refinery hydrotreating / HDS (hydrogenation desulfurization)
CO₂ capture, utilization & storage (CCUS)
Syngas purification and ammonia plants
For detailed sizing, material selection, or a complete API 610 pump proposal for your amine service, please contact us.
Email: info@hyrig.com
*Our engineers are ready to support your rich amine / lean amine pumping needs – from OH2 to BB3 to VS4.*
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.