Antiscalant Transfer Pumps – API 610 BB, OH & VS

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Our API 610 antiscalant transfer pumps are available in BB, OH, and VS designs, specifically engineered for the reliable loading, unloading, and transfer of antiscalant chemicals from storage tanks to day tanks, injection systems, and process units in water treatment plants, cooling water systems, reverse osmosis facilities, and oilfield operations. BB pumps provide superior rotor stability for high‑flow, high‑pressure main transfer duties. OH pumps offer compact solutions for smaller transfer or booster services, while VS pumps handle low‑NPSH suction from chemical storage tanks. Built with stainless steel, duplex, and corrosion‑resistant materials to withstand chemical attack and prevent contamination. Fully API 610/ISO 13709 compliant for reliable, safe antiscalant transfer service.

Conatct For Details
DetailReview(0)Additional

Our API 610 antiscalant transfer pumps are heavy‑duty centrifugal pumps engineered specifically for the reliable loading, unloading, and transfer of antiscalant chemicals – also known as scale inhibitors – from bulk storage tanks to day tanks, injection systems, and process units in water treatment plants, cooling water systems, reverse osmosis (RO) facilities, oilfield operations, and industrial processes. Antiscalants are chemical agents used to prevent the precipitation and deposition of mineral scales (calcium carbonate, calcium sulfate, barium sulfate, silica, etc.) on equipment surfaces, heat exchangers, membranes, and pipelines. These chemicals are typically stored in concentrated form and must be transferred safely and efficiently to injection points where they are diluted and dosed into the process stream. Pumps for this service demand excellent chemical compatibility, reliable sealing to prevent leaks of potentially hazardous chemicals, and robust construction for intermittent or continuous transfer operations. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for maximum safety, reliability, and longevity in the most demanding chemical transfer applications. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – with selection based on flow rate, head, NPSH availability, and installation requirements.

API 610 Classifications for Antiscalant Transfer Duties

  • BB – Between Bearings Pumps
    For main high‑capacity antiscalant transfer from bulk storage to day tanks or injection systems, BB pumps provide superior rotor stability and long‑term reliability. BB1 (axially split, double‑suction) and BB2 (radially split, single‑stage or two‑stage) configurations are commonly specified for flows from 10 to 500 m³/h and heads up to 250 metres. The between‑bearings arrangement minimises shaft deflection, extending seal and bearing life – critical for continuous or frequent transfer operations. Double‑suction designs (BB1) balance axial thrust at high flows.

  • OH – Overhung Pumps
    For moderate‑capacity antiscalant transfer, booster duties, or smaller loading applications, OH pumps offer a compact and cost‑effective solution. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes are widely used for antiscalant transfer from drums or totes to day tanks, and for small‑scale loading operations. Centreline mounting accommodates thermal expansion. Their back‑pull‑out design allows easy seal and impeller maintenance without disturbing piping. Single‑stage OH pumps handle flows up to 200 m³/h and heads up to 200 metres.

  • VS – Vertically Suspended Pumps
    In applications where antiscalant is drawn from low‑NPSH underground storage tanks, sumps, or bulk storage vessels, VS pumps provide excellent suction performance. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the impeller below the liquid level, eliminating cavitation and priming problems. Their vertical footprint saves valuable plot space.

Key Performance & Design Features

  • Flow Range – Capacities from 1 m³/h to 500 m³/h, covering all antiscalant transfer requirements.

  • Head Range – Up to 300 metres for high‑head transfer to elevated day tanks or injection systems.

  • Temperature Range – Designed for antiscalants from ambient to 60°C (140°F), with appropriate material selection.

  • Chemical Compatibility – Wetted parts manufactured from stainless steels (304L, 316L, duplex), high‑alloy materials, and corrosion‑resistant coatings to withstand chemical attack from antiscalant formulations.

  • Leak Prevention – API 682 mechanical seals – single or dual (tandem) seals depending on service requirements. Suitable flush plans (Plan 11, 13, 32, 53A/B) with cooling to maintain seal integrity.

  • Casing Design – Robust casings with replaceable wear rings; smooth internal surfaces to minimise chemical degradation and fouling.

  • Bearing & Lubrication – Heavy‑duty bearings (oil or grease lubricated) with temperature and vibration monitoring for predictive maintenance.

  • Impeller Options – Closed impellers for efficient handling; special hydraulics for low‑flow, high‑head transfer duties.

  • Material Traceability – All wetted materials are fully traceable with certified mill test reports (MTRs).

Typical Applications

  • Antiscalant transfer from bulk storage tanks to day tanks

  • Loading and unloading of antiscalant chemicals from drums, totes, or tankers

  • Antiscalant supply to injection systems in water treatment plants

  • Chemical transfer in reverse osmosis (RO) and membrane systems

  • Scale inhibitor transfer in cooling water treatment facilities

  • Antiscalant handling in oilfield waterflood operations

Industries Served

  • Water and wastewater treatment

  • Oil refineries and petrochemicals

  • Oil and gas production (waterflooding)

  • Power generation (cooling water treatment)

  • Chemical processing

  • Desalination plants

  • Industrial manufacturing

Why Choose Our Antiscalant Transfer Pumps?

With extensive experience in chemical handling and full API 610 compliance, we design and manufacture antiscalant transfer pumps that combine reliability, safety, and corrosion resistance. Every pump undergoes rigorous performance testing, hydrostatic testing, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet international specifications. We offer customised hydraulic designs, material selections, and sealing arrangements to match your specific antiscalant formulation, transfer pressure, and flow requirements. Our engineering support includes NPSH analysis, API 684 rotor dynamics, material compatibility evaluation, and system integration advice to ensure long‑term, trouble‑free operation.

Contact Us

For technical datasheets, selection assistance, or a customised quotation, please contact us at:

info@hyrig.com

Rely on our API 610 antiscalant transfer pumps to deliver safe, reliable handling of your antiscalant chemicals from storage to point of use.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit