The API 610 OH2 A8 Stripper Overhead Product C Pump (also referred to as Benzene/Toluene Overhead Pump or Aromatic Stripper Top Pump) is a heavy‑duty, overhung (OH2) centrifugal pump designed for reliable transfer of overhead product from an A8 stripper column in aromatics complexes. The stream contains 43.56% benzene, 54.13% toluene, and trace ethylbenzene and xylene. It delivers a head of 127.4 meters at a flow rate up to 57.9 m³/h (normal 31.6 m³/h, rated 52.7 m³/h, maximum 57.9 m³/h), handling the benzene/toluene mixture at 49°C (typical density ~850‑880 kg/m³).
| Parameter | Value |
|---|---|
| Pump type | API 610 OH2 (overhung, centerline‑mounted) |
| Flow rate (normal / rated / max) | 31.6 / 52.7 / 57.9 m³/h |
| Head | 127.4 m |
| Medium | Benzene (43.56%) / toluene (54.13%) mixture |
| Operating temperature | 49 °C |
| Mechanical seal | API 682 Plan 11 + 52 (dual unpressurized with external flush) |
| Compliance | API 610 (ISO 13709) 11th+ Edition |
Engineered for continuous stripper overhead product service, this OH2 centrifugal pump provides excellent rotor dynamics and stability. The centerline mounting ensures proper alignment under thermal expansion, while the overhung design facilitates easy maintenance with back‑pullout capability. The API 682 Plan 11+52 mechanical seal arrangement provides enhanced reliability for volatile aromatic service.
This API 610 OH2 pump is a direct replacement for the following world‑leading brands – no baseplate or piping modifications required:
Sulzer – OHHL32-40 series
Flowserve – HPXM32/40 series
Goulds (Xylem) – 3700 2×3-13 series
All replacements deliver identical performance, hydraulic coverage, nozzle orientation, and footprint. You can replace your existing pump with Hyrig’s API 610 OH2 unit without any engineering changes to your piping or foundation.
High head, low flow – 127.4 m at up to 57.9 m³/h – ideal for stripper overhead product
Aromatic service – suitable for benzene/toluene mixtures
API 682 Plan 11+52 seal – dual unpressurized with external flush for volatile service
API 610 11th+ Edition compliant – meets all requirements for petrochemical critical service
Better cost‑effectiveness – up to 30% savings compared to original OEM quotes
Shorter delivery times – stocked components and rapid assembly
Full technical support – including performance curves, GA drawings, and material certifications
A8OP‑OH2 (A8 Stripper Overhead Product – OH2)
BTP‑OH2 (Benzene/Toluene Product – OH2)
Project tag – per customer standards (e.g., 2040-P-XXXX)
Hyrig specializes in supplying API 610 standard process centrifugal pumps (OH2, BB2, BB5, VS6). Our core strength lies in providing complete drop‑in replacements for Sulzer, Flowserve, and Goulds (Xylem). Every replacement pump is manufactured to exact OEM interface dimensions, ensuring seamless installation.
We offer:
Identical performance – verified by hydraulic testing
Same quality – ISO 9001, API 610, and customer-specified material grades
Full compliance – with all applicable industry standards
Better cost‑effectiveness – competitive pricing without compromising reliability
Shorter delivery times – expedited schedules available for critical turnarounds
For inquiries, please contact us at: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.