This API RP 13C mesh size chart provides the standardized correlation between D100 micron cut points and API screen numbers. Use this guide to accurately select replacement shaker screens for your specific drilling fluid requirements.
Conatct For Details
DetailReview(0)Additional

Key Facts

  • Standard: API RP 13C
  • Key Metric: D100 Separation (Microns)
  • Purpose: Standardized testing and labeling for shaker screens
  • Application: Screen selection based on mud weight and formation

API RP 13C D100 Separation and API Screen Number

Data source: Technical data table.

D100 Separation (μm)API Screen Number
> 3,075.0 to 3,675.0API 6
> 2,580.0 to 3,075.0API 7
> 2,180.0 to 2,580.0API 8
> 1,850.0 to 2,180.0API 10
> 1,550.0 to 1,850.0API 12
> 1,290.0 to 1,550.0API 14
> 1,090.0 to 1,290.0API 16
> 925.0 to 1,090.0API 18
> 780.0 to 925.0API 20
> 655.0 to 780.0API 25
> 550.0 to 655.0API 30
> 462.5 to 550.0API 35
> 390.0 to 462.5API 40
> 327.5 to 390.0API 45
> 275.0 to 327.5API 50
> 231.0 to 275.0API 60
> 196.0 to 231.0API 70
> 165.0 to 196.0API 80
> 137.5 to 165.0API 100
> 116.5 to 137.5API 120
> 98.0 to 116.5API 140
> 82.5 to 98.0API 170
> 69.0 to 82.5API 200
> 58.0 to 69.0API 230
> 49.0 to 58.0API 270
> 41.5 to 49.0API 325
> 35.0 to 41.5API 400
> 28.5 to 35.0API 450
> 22.5 to 28.5API 500
> 18.5 to 22.5API 635

Structure / Working Principle

API RP 13C defines the testing and labeling procedure for shaker screens. The Cut Point Testing (D100) uses a standardized dry sieve method to determine the maximum particle size that will pass through the screen. The API number denotes this cut point, not the physical mesh count.

A Conductance Test measures the fluid's ability to flow through the screen at a predetermined pressure drop (measured in kD/mm). A higher conductance means fluid passes more easily.

When selecting a screen, the API number is the most reliable indicator of performance, as physical mesh counts can vary between manufacturers.

Cross-Reference & Replacement

Using this chart, you can cross-reference the D100 micron rating of your current screens to find the correct API number for your replacement screens, regardless of the brand. For a guide on mesh types (MG, HC, XL, XR), view our Mesh Types Guide.

Selection Support

Need help determining which API mesh size is right for your current drilling phase? Tell us your mud weight (PPG) and flow rate, and our engineers will recommend the optimal cut point.

Applications

This chart applies to all shale shaker screens used in onshore and offshore drilling operations.

(Disclaimer: Please follow standard industrial safety procedures during screen installation and maintenance.)

Spare Parts

View our screens: Mongoose Pro Screens | Derrick FLC 500 Screens.

Frequently Asked Questions

Q: What is D100?

A: D100 is the particle size in microns at which 100% of the particles larger than that size are retained by the screen. It is used to define the API screen number.

Q: Why doesn't my screen label match the mesh count?

A: API RP 13C standardized the labeling based on measured cut points, not physical mesh counts. An API 200 screen may have a different physical mesh count from a different manufacturer, but the D100 cut point will be the same.

Contact

For help selecting the correct API mesh screen, contact HYRIG: info@hyrig.com

Related

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit