The AH37001-05.02 is an original equipment manufacturer (OEM) FLUID END produced by Baoji Oilfield Machinery (BOMCO) specifically for the F1600HL (1600 HP) high‑pressure, high‑flow triplex mud pump. This FLUID END is the flagship high‑pressure core of the fluid end system, engineered with an L‑type high‑flow structure and rated at 7,500 psi (51.7 MPa) – a 50% pressure increase over the standard F1600 FLUID END (5,000 psi). It serves as both a hydraulic cylinder and a complete hydraulic box, converting mechanical power into extreme hydraulic pressure for ultra‑deep wells, extended‑reach horizontal wells, and high‑pressure jet drilling.
Key Specifications
| Parameter | BOMCO F1600HL FLUID END |
|---|---|
| OEM Part No. (single FLUID END cylinder) | AH37001-05.02 |
| Complete FLUID END Assembly (3 units) | AH1601HL010500 |
| Pump Model | BOMCO F1600HL (1600 HP, 120 SPM, 12″ / 305 mm stroke) |
| Working Pressure | 7,500 psi (51.7 MPa) – 50% higher than standard F1600 |
| Hydrostatic Test Pressure | 11,250 psi (77.6 MPa) – 1.5× rated |
| Max Liner ID | 190 mm (7‑1/2″) – larger than standard F1600 (180 mm) |
| Valve Type | API #7 high‑pressure suction & discharge valves |
| Material | 42CrMo ultra‑high‑strength alloy forged steel |
| Hardness (tempered) | 285–341 HB (10% higher than standard F1600) |
| Surface Treatment | Electroless nickel plating + H₂S resistant coating |
| Single FLUID END Weight | ~55 kg (15% heavier than standard F1600) |
| Operating Temperature | -20°C to +130°C |
Structural & Design Advantages – A True Ultra‑High Pressure FLUID END
L‑type high‑flow layout – Large‑diameter, short, smooth flow passages with a 20% larger cross‑sectional area than standard F1600 FLUID END. This hydraulic box delivers 11.4% higher output (up to 51.85 L/s) while reducing erosion and pressure loss.
Enhanced valve‑over‑valve configuration – Suction valve (bottom) and discharge valve (top) in each hydraulic cylinder, optimized for high‑viscosity, high‑sand drilling fluids, minimizing cavitation risk even at extreme flow rates.
Thick‑wall forged heavy‑duty body – Critical wall thickness increased by 50% compared to standard F1600 FLUID END, resisting fatigue cracks under 7,500 psi cyclic service – essential for 7,000–9,000 meter ultra‑deep wells.
Heavy‑duty tapered buttress thread cylinder head – Eliminates loosening and leakage under extreme pressure and vibration.
Metal‑to‑metal rigid high‑pressure seals – Every FLUID END features metal sealing on flange faces and valve covers, API 7K compliant, zero leakage under cyclic 7,500 psi operation.
API #7 quick‑access valve covers – Replace valve seats/inserts without disassembling the entire FLUID END. Independent chambers allow single‑unit maintenance without affecting others.
Limited interchangeability – The three FLUID END units on the same pump are identical, but this FLUID END is NOT interchangeable with standard F1300/F1600 FLUID END due to higher pressure rating, larger flow passages, and different liner fit.
Why Choose This BOMCO F1600HL FLUID END?
Ultra‑high pressure OEM fit, extreme reliability – Exact BOMCO engineering for F1600HL pump at 7,500 psi. 100% dimensional and pressure match, eliminating assembly deviation, leakage, and vibration. Compliant with API 7K.
Forged ultra‑high‑pressure durability – 42CrMo alloy forging + enhanced heat treatment (285–341 HB) outperforms standard FLUID END components. Resists erosion, corrosion, and fatigue under high‑sand, high‑temperature, high‑pressure, and H₂S‑laden ultra‑deep well conditions.
L‑type high‑flow efficiency – 11.4% greater output, optimized suction, reduced cavitation, increased volumetric efficiency – ideal for extended‑reach horizontal wells and high‑pressure jet drilling.
Modular heavy‑duty maintenance – Quick‑change valve design cuts maintenance time by up to 50%. Reduces non‑productive time for ultra‑deep well drilling operations.
Applications – The Ultimate FLUID END for Extreme Drilling
BOMCO F1600HL triplex mud pump – oil & gas ultra‑deep wells (7,000–9,000 meters), extended‑reach horizontal wells, high‑pressure jet drilling, onshore and offshore.
Suitable drilling environments – Ultra‑deep wells, high‑pressure (≤7,500 psi), high‑sand, high‑temperature (up to 130°C), high‑H₂S drilling fluids.
Compatible components – Pairs with API #7 high‑pressure suction valves, discharge valves, 190 mm (7‑1/2″) liners, high‑pressure pistons, and piston rods as a complete ultra‑high pressure FLUID END system.
Procurement & Replacement Notes
Order AH37001-05.02 for individual F1600HL FLUID END units (each functions as a hydraulic cylinder / hydraulic box).
Order AH1601HL010500 for the complete FLUID END assembly (three units).
Compatibility note – This FLUID END is exclusive to F1600HL. It is NOT interchangeable with standard F1600 or F1300 FLUID END due to higher pressure rating, larger flow passages, and 190 mm liner fit.
Maintenance tips – Inspect ultra‑high pressure seals weekly. Re‑tighten cylinder head bolts to specified torque quarterly. Perform magnetic particle inspection after high‑pressure service. Replace high‑pressure seals every 500 operating hours for long‑term reliability.
Contact for Genuine BOMCO F1600HL FLUID END
For pricing, technical datasheets, or ready stock of the BOMCO F1600HL high‑pressure FLUID END (AH37001-05.02 / AH1601HL010500) , please email:
info@hyrig.com
OEM quality, global shipping. Complete FLUID END solutions for F1600HL and other BOMCO high‑pressure pump models available.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.