Our API 610 debutanizer bottom pumps are heavy‑duty centrifugal pumps engineered specifically for circulating high‑temperature hydrocarbon bottoms from the bottom of debutanizer columns through reboiler heat exchangers and to downstream processing units in refineries, NGL fractionation plants, and petrochemical facilities. The debutanizer column separates butane (C4) and heavier components from lighter propane (C3) and lighter hydrocarbons, with the bottom stream typically consisting of C4+ hydrocarbons including normal butane, isobutane, and heavier fractions. The bottom stream must be continuously circulated through a reboiler to supply heat for the distillation process, and is then pumped to storage or downstream processing. This fluid is characterized by elevated temperatures (typically 150‑220°C), moderate viscosity, fouling tendencies, and potential corrosivity from sulfur compounds. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for reliable, continuous operation under severe conditions. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – though the BB2 type (radially split, single‑stage or two‑stage) is the industry standard for main debutanizer bottom circulation duty.
API 610 Classifications for Debutanizer Bottom Duties
BB2 – Between Bearings Pumps (Preferred for Main Bottom Circulation)
For the main debutanizer bottom circulation pump, the BB2 subtype (radially split, single‑stage or two‑stage, between‑bearings) is the overwhelmingly preferred configuration. The radially split casing is ideal for high‑temperature hydrocarbon service, allowing the casing to expand evenly with temperature without distorting internal clearances – critical when handling streams with significant temperature differentials. The between‑bearings arrangement provides exceptional rotor rigidity, minimising shaft deflection and vibration. Single‑stage BB2 pumps handle high flows (up to 2,500 m³/h) at moderate heads, while two‑stage variants cover higher head requirements. The robust bearing span and heavy‑duty shaft ensure long life even with fouling‑prone hydrocarbon streams.
OH – Overhung Pumps
In debutanizer bottom systems, OH pumps are typically employed for startup circulation, booster duties, or trim cooler services where temperatures and flows are lower. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes provide compact, cost‑effective solutions for auxiliary roles. Centreline mounting ensures thermal expansion does not misalign the pump and driver.
VS – Vertically Suspended Pumps
VS pumps are used on the suction side of debutanizer systems or for handling bottoms with very low NPSH. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the first‑stage impeller in the column bottom sump, providing excellent NPSH performance. They are also used in closed‑loop systems where floor space is limited.
Key Performance & Design Features (BB2 Focus)
Temperature Capability – Engineered for hydrocarbon temperatures up to 220°C (428°F), with appropriate material selection and thermal expansion allowances.
Flow & Head – Capacities from 50 m³/h to over 2,500 m³/h; heads typically from 50 to 200 metres, matching reboiler exchanger pressure drop.
Casing Design – Radially split casing with top‑centreline or bottom‑centreline support to accommodate thermal expansion without distortion. Heavy‑wall construction for pressure integrity at elevated temperatures.
Materials – Wetted parts in chrome‑moly steels (ASTM A217 WC6/WC9), 12% chrome stainless steels, duplex stainless, or high‑alloy materials for corrosion resistance to sulfur and organic acids. Full hard facing on wear rings and impeller shrouds to resist fouling and erosion.
Fouling Resistance – Impeller and casing designs that minimise stagnant areas and coke deposition; optional steam tracing or jacketing to maintain fluidity and prevent polymerisation.
Sealing – API 682 mechanical seals (single, dual, or tandem) with high‑temperature flush plans – typically Plan 32 (clean injected flush), Plan 62 (steam quench), or Plan 53 (pressurised dual seal) – to prevent coke formation and ensure seal face stability. Steam quench is strongly recommended for hydrocarbon services to flush away any leakage and prevent coke build‑up.
Bearing & Lubrication – Heavy‑duty sleeve or tilting‑pad journal bearings and Kingsbury‑type thrust bearings with forced oil lubrication; bearing temperature and vibration monitoring for predictive maintenance.
Impeller Options – Closed impellers with large clearances to handle thermal expansion and minor fouling; open or semi‑open designs for severe fouling services; all dynamically balanced per API 610.
Thermal Expansion – Adequate internal clearances, expansion joints, and flexible coupling designs to accommodate significant temperature gradients.
Typical Applications
Hydrocarbon bottoms circulation in debutanizer columns
Reboiler circulation in refinery light ends fractionation
Butane and heavier bottoms transfer to storage or downstream processing
Debutanizer bottom circulation in NGL fractionation plants
Any fractionator handling C4+ hydrocarbon fractions requiring forced‑circulation reboilers
Industries Served
Oil refineries (light ends fractionation)
Natural gas processing (NGL fractionation)
Petrochemicals (C3/C4 separation and upgrading)
Why Choose Our Debutanizer Bottom Pumps?
With deep expertise in high‑temperature hydrocarbon pumping and full API 610 compliance, we design and manufacture BB2 debutanizer bottom pumps that deliver unmatched reliability, safety, and efficiency. Every pump undergoes rigorous hydrostatic testing, performance curve verification, mechanical running tests, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet the most stringent owner‑operator specifications. We offer customised hydraulic designs, material upgrades, fouling‑resistant impeller designs, and sealing arrangements tailored to your specific hydrocarbon composition, temperature, and fouling characteristics. Our engineering support includes API 684 rotor dynamics, thermal expansion analysis, and NPSH margin studies to ensure seamless, long‑term operation in the most demanding debutanizer services.
Contact Us
For technical datasheets, application engineering advice, or a project‑specific quotation, please contact us at: