1. Product Overview
The OH2 Series Diesel Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 (ISO 13709) international standards. It is purpose-built for demanding industrial applications such as oil refining, petrochemical processing, oil & gas terminals, marine, and power generation. This pump is specifically engineered to handle diesel fuel (including 0# diesel, -10#/-20# low-temperature diesel, marine diesel oil), and is designed for low viscosity, flammable/explosive, continuous operation, and frequent start-stop conditions. It is a critical fluid transfer device for diesel storage & turnaround, fueling/dispensing, and power system support.
Model Code Interpretation (OH2):
O = Overhung: Impeller is positioned outside the bearing housing – compact structure, facilitating explosion-proof seal design and reducing diesel stagnation space.
H = Horizontal: Horizontal mounting, compatible with pipeline layouts of diesel storage tanks, dispensers, generator sets, and related equipment – easy installation and maintenance.
2 = 2nd Generation: Centerline support design (vs. foot-mounted OH1) – superior operational stability for long-term continuous diesel transfer (annual operation rate ≥99%).
2. Key Structural Features
Centerline Mounting + Stable Operation Design: Pump casing is supported along the horizontal centerline. Over a wide temperature range (-80°C to +450°C), thermal expansion/contraction maintains perfect shaft alignment, avoiding leakage risks caused by equipment vibration during diesel transfer, ensuring safe handling of flammable/explosive media.
Radially Split + Efficient Maintenance Design: The casing splits vertically. Maintenance can be performed without removing inlet/outlet piping – the "back pull-out" design allows rotor assembly extraction, drastically shortening downtime. Smooth, dead‑free flow passages reduce sediment accumulation from trace impurities in diesel, lowering wear and extending equipment life.
Single-Stage Overhung + Low-Viscosity Flow Path: Single impeller + single bearing housing – the impeller features high specific speed optimization for diesel’s low viscosity (typically 2–10 mm²/s), boosting transfer efficiency up to 75–85%. Optimized impeller inlet reduces Net Positive Suction Head required (NPSHr ≤3 m), suitable for low liquid level diesel storage tank transfer.
API 682 Explosion-Proof Sealing System: Standard cartridge single mechanical seal (dedicated for flammable/explosive media). Supports Plan 11/21 flush plans. Leakage ≤5 ppm. Seal chamber features flameproof design, meeting Ex d IIB T4 explosion protection rating, eliminating fire/explosion risks from diesel leakage. Friction pairs use wear-resistant materials (silicon carbide + graphite), matching diesel cleanliness requirements and reducing seal wear.
3. General Technical Specifications (Industry Standard Range)
Capacity: 3 – 2,600 m³/h (customizable up to 3,000 m³/h) – suitable for both high-volume diesel turnover and low-flow dispensing
Head: 30 – 395 m (max. 1,300 ft) – meets long-distance transfer and high-pressure dispensing requirements
Operating Temperature: -80°C to +450°C (-150°F to +842°F); typical diesel service: -40°C to +80°C (low-temperature diesel down to -50°C)
Operating Pressure: Standard 50 bar (725 psi); customizable up to 100 bar (1,450 psi) for high-pressure dispensing systems
Speed: 50Hz: 1,500/3,000 rpm; 60Hz: 1,800/3,600 rpm – low speed for precision dispensing, high speed for high-volume turnover
Flange Rating: Class 150/300/600# (RF sealing face, ASME B16.5) – gaskets with oil-resistant rubber + metal wound construction
Material Options: Carbon steel (WCB – mainstream choice for standard diesel), Stainless steel (304/316 for high-purity and low-temperature diesel), Low-temperature steel (A352 LCB for diesel below -40°C)
4. Global Equivalent Models (API 610 OH2 for Diesel)
Sulzer OHH series (OHH25-200, OHH40-250, OHH80-400): Capacity 25–400 m³/h, Head 50–370 m – diesel terminal storage & turnover dedicated
Flowserve HPX series (HPX310, HPX410, HPX510): Capacity 50–2,000 m³/h, Head 40–350 m – marine diesel fuel oil system adapted, upgraded explosion protection
CPC HR/HOR series (HR150-300, HOR200-350): Capacity 100–2,272 m³/h, Head 50–395 m – large refinery diesel product transfer & truck loading
Rodelta HZC series (HZC50-250, HZC80-315): Capacity 50–1,920 m³/h, Head 30–380 m – high-efficiency low-viscosity design, energy optimized
Amarinth OH2 series (custom low-temperature models): Capacity 10–500 m³/h, Head 40–250 m – designed for diesel service below -40°C
KSB KZE series (KZE80-200, KZE100-315): Capacity 30–200 m³/h, Head 50–160 m – API 610 12th edition compliant, diesel generator set fuel supply pump
5. Complete OH2 Diesel Pump Model Lineup (20 Core Models for Selection)
Model: Diesel Pump 40-250 OH2
Definition: API 610 OH2, DN40 outlet, 250mm impeller – diesel dedicated
Capacity/Head: 25–50 m³/h / 80–110 m
Typical Application: Small diesel dispensing station, generator set fuel supply pump
Model: Diesel Pump 50-160 OH2
Definition: API 610 OH2, DN50 outlet, 160mm impeller – diesel general purpose
Capacity/Head: 30–60 m³/h / 35–50 m
Typical Application: Small/medium diesel storage turnover, small vessel fuel oil pump
Model: Diesel Pump 50-200 OH2
Definition: API 610 OH2, DN50 outlet, 200mm impeller – diesel standard
Capacity/Head: 30–65 m³/h / 50–70 m
Typical Application: Diesel truck loading, small refinery product transfer pump
Model: Diesel Pump 50-250 OH2
Definition: API 610 OH2, DN50 outlet, 250mm impeller (high pressure) – diesel high pressure
Capacity/Head: 30–65 m³/h / 80–115 m
Typical Application: High-pressure diesel dispensing system, construction machinery fuel pump
Model: Diesel Pump 65-160 OH2
Definition: API 610 OH2, DN65 outlet, 160mm impeller (medium flow low pressure)
Capacity/Head: 50–100 m³/h / 32–48 m
Typical Application: Large diesel storage turnover, gas station central fuel pump
Model: Diesel Pump 65-200 OH2
Definition: API 610 OH2, DN65 outlet, 200mm impeller (general purpose)
Capacity/Head: 50–110 m³/h / 48–72 m
Typical Application: Petrochemical diesel product truck loading, medium vessel fuel system
Model: Diesel Pump 65-250 OH2
Definition: API 610 OH2, DN65 outlet, 250mm impeller (medium-high pressure)
Capacity/Head: 50–110 m³/h / 75–110 m
Typical Application: Long-distance diesel pipeline, high-pressure cleaning equipment fuel pump
Model: Diesel Pump 65-315 OH2
Definition: API 610 OH2, DN65 outlet, 315mm impeller (high head)
Capacity/Head: 50–110 m³/h / 120–160 m
Typical Application: Mountainous diesel transfer, large generator set high-pressure fuel pump
Model: Diesel Pump 80-160 OH2
Definition: API 610 OH2, DN80 outlet, 160mm impeller (large flow low pressure)
Capacity/Head: 80–160 m³/h / 30–48 m
Typical Application: 10+ Mt/y refinery diesel export, large tank farm turnover pump
Model: Diesel Pump 80-200 OH2
Definition: API 610 OH2, DN80 outlet, 200mm impeller (main duty)
Capacity/Head: 80–160 m³/h / 48–72 m
Typical Application: Diesel dock loading, large logistics park central fuel pump
Model: Diesel Pump 80-250 OH2
Definition: API 610 OH2, DN80 outlet, 250mm impeller (large flow medium-high pressure)
Capacity/Head: 80–160 m³/h / 75–115 m
Typical Application: Long-distance diesel pipeline, large vessel fuel main pump
Model: Diesel Pump 80-315 OH2
Definition: API 610 OH2, DN80 outlet, 315mm impeller (large flow high pressure)
Capacity/Head: 80–160 m³/h / 120–165 m
Typical Application: High-pressure diesel network, large construction equipment central fuel pump
Model: Diesel Pump 100-200 OH2
Definition: API 610 OH2, DN100 outlet, 200mm impeller (large flow)
Capacity/Head: 120–220 m³/h / 45–70 m
Typical Application: Extra-large tank farm turnover, integrated refining & petrochemical diesel transfer pump
Model: Diesel Pump 100-250 OH2
Definition: API 610 OH2, DN100 outlet, 250mm impeller (large flow medium pressure)
Capacity/Head: 120–220 m³/h / 70–110 m
Typical Application: International diesel pipeline, large port loading main pump
Model: Diesel Pump 100-315 OH2
Definition: API 610 OH2, DN100 outlet, 315mm impeller (large flow high pressure)
Capacity/Head: 120–220 m³/h / 115–160 m
Typical Application: High-pressure diesel dispensing station, large power plant backup diesel fuel pump
Model: Diesel Pump 100-400 OH2
Definition: API 610 OH2, DN100 outlet, 400mm impeller (ultra-high head)
Capacity/Head: 120–220 m³/h / 180–240 m
Typical Application: Ultra-high pressure diesel system, long-distance mountainous diesel transfer
Model: Diesel Pump 125-250 OH2
Definition: API 610 OH2, DN125 outlet, 250mm impeller (very large flow)
Capacity/Head: 200–350 m³/h / 65–100 m
Typical Application: National strategic reserve turnover, large refinery finished product main transfer pump
Model: Diesel Pump 125-315 OH2
Definition: API 610 OH2, DN125 outlet, 315mm impeller (very large flow high pressure)
Capacity/Head: 200–350 m³/h / 110–155 m
Typical Application: International diesel dock loading, ultra-large tank farm main transfer pump
Model: Diesel Pump 150-315 OH2
Definition: API 610 OH2, DN150 outlet, 315mm impeller (extra-large flow)
Capacity/Head: 300–550 m³/h / 90–140 m
Typical Application: Cross-border diesel pipeline, 10+ Mt/y refinery diesel export main pump
Model: Diesel Pump 150-400 OH2
Definition: API 610 OH2, DN150 outlet, 400mm impeller (top large flow high pressure)
Capacity/Head: 300–550 m³/h / 160–220 m
Typical Application: Ultra-large tank farm high-pressure turnover, global large diesel terminal main pump
6. Contact Us
For detailed technical datasheets, model selection assistance, customized quotations, or sample requests, please contact:
Email: info@hyrig.com
Our engineering team responds within 24 hours with API 610 compliant solutions tailored to your diesel transfer and fueling system needs.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.