This Dimethyl Ether (DME) Transfer Pump model SZE100-200 is designed and manufactured in China to fully comply with API 610 (ISO 13709) 11th edition, OH2 configuration – horizontal, centerline mounted, single‑stage, overhung, radially split casing. It is specifically engineered for reliable transfer of dimethyl ether, a volatile, flammable liquefied gas used as a clean fuel, LPG blend component, aerosol propellant, and chemical intermediate.
Why DME Transfer Requires API 610 OH2
DME has a low boiling point (-24°C), high vapor pressure, and low viscosity. It can cause cavitation if NPSH is insufficient, and is flammable, requiring high integrity sealing. The OH2 pump provides:
Low NPSH impeller options to prevent cavitation
Centerline mounting for thermal stability during cold or ambient operation
API 682 dual mechanical seals to prevent leakage of hazardous gas
Back pull-out design for easy maintenance without disconnecting piping
Key Mechanical Features
Radially split, centerline mounted casing – maintains alignment under temperature changes
Overhung impeller with heavy duty angular contact bearings
Single or dual volute casing – reduces radial thrust at off‑BEP conditions
Rigid shaft with back pull‑out design – allows seal and bearing replacement without disturbing piping
Suitable for low temperature service (-40°C with appropriate materials)
Hydraulic Design
Closed impeller for clean DME. Low NPSH impeller or inducer option for applications with low suction head. Trimmed impeller available for exact duty point.
Performance Range
| Parameter | Value |
|---|---|
| Flow rate | up to 400 m³/h |
| Head | up to 60 m (SZE100-200) |
| Temperature | -40°C to +80°C |
| Design pressure | up to 2.5 MPa (25 bar) |
Materials for DME Service
Carbon steel (WCB/LCC) – standard for clean DME
Stainless steel 304/316 – for high purity or moisture control
Elastomers: FKM (Viton) or NBR – compatible with DME (EPDM is not suitable)
NACE MR0175 compliance available for sour gas blending
Sealing System
API 682 compliant seal chamber. DME is flammable and volatile:
Dual pressurized mechanical seal with Plan 53B (pressurized barrier fluid) – recommended
Tandem seal with Plan 52 (unpressurized buffer fluid) for lower emissions
Single seal with Plan 11 + quench (Plan 62) for non-hazardous indoor locations
Seal face materials: silicon carbide vs carbon or hard-on-hard (SiC/SiC) for dry run protection.
Bearing and Lubrication
Oil bath lubrication standard. For low temperature DME, synthetic oil or grease recommended. Cooling coils for higher temperature operation.
Quality and Testing
Each DME transfer pump is hydrostatically tested, performance tested, and mechanically run‑in per API 610. Low NPSH test available on request. Helium leak test for seal housing. Full documentation includes material certificates and test reports.
Typical Applications
DME transfer from storage to loading (truck, railcar, ship)
DME circulation in DME-to-olefins (DTO) or DME-to-gasoline processes
LPG blending pump for DME/LPG mixtures
Solvent and propellant feed in aerosol filling plants
Model SZE100-200 Specifics
The SZE100-200 designation indicates a horizontal overhung pump with nominal discharge size 100 mm (4 inches), impeller nominal diameter 200 mm (7.9 inches), designed for medium flow, low to medium head transfer duties. This model is ideal for DME circulation and transfer applications.
Safety Features for DME Service
Explosion-proof motor (Class I, Division 1 or 2, Group B)
Dual mechanical seals with leak detection and collection
Earth bonding for static charge dissipation
Casing pressure relief valve option
Complete Pump Package
We supply the DME transfer pump with explosion-proof motor, coupling, baseplate, seal support system (Plan 53B), and instrumentation – all from a single source.
Contact
For engineering data, material recommendations, or a quotation for your DME transfer application, please contact info@hyrig.com.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.