| Model | Nominal Size | Max Pressure (Steel) | Material Options | Mounting Types |
|---|---|---|---|---|
| DV/DRV6 to 40 | DN6 - DN40 | Up to 35 MPa | Steel / Brass / SS | In-line / Subplate |
Data source: Technical data table.
The valve body contains an adjustable throttling needle. Turning the knob counterclockwise opens the throttle, while clockwise closes it. The DRV type adds a built-in check valve, allowing free flow in one direction (B to A) and precise throttling in the other (A to B).
The model code is built as follows: `DV/DRV` + `Mounting` + `Size` + `10` + `Thread` + `Material` + `Options`.
Example: `DRV10-10/2` = One-way throttle stop valve, DN10, 10 series, metric thread, brass body.
Used in hydraulic systems requiring precise speed control and complete shut-off, such as test stands, machine tools, and hydraulic power packs.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Not sure whether you need the DV or DRV, or which material is suitable for your fluid? Contact our engineers with your specifications.
Q: What is the difference between DV and DRV?
A: DV is a pure throttle stop valve (bidirectional). DRV is a one-way throttle stop valve that allows free reverse flow through a check valve.
Q: Does the valve completely stop the flow when closed?
A: Yes, when fully turned in, the valve provides a zero-leak shut-off.
Q: What is the pressure rating for brass versions?
A: Brass versions are rated up to 15 MPa, while steel versions handle up to 35 MPa.
Q: Can I lock the flow setting?
A: Yes, a set screw is provided to lock the adjustment knob at the desired flow setting.
For DV/DRV throttle stop valve selection and spare parts, contact HYRIG: info@hyrig.com