The EAP-D50-250 is a horizontal, single-stage, single-suction OH2 overhung centrifugal pump designed to API 610 (ISO 13709). Flow range 36-576 m³/h, head 15-200 m, speed 2900/1450 rpm, design pressure ≤2.5 MPa, temperature -40°C to +200°C. OH2 centerline-mounted with back pull-out design, impeller back vanes, single volute casing, and heavy-duty bearings exceeding 17,500 hours. API 682 seal compatible. Direct replacement for Sulzer PRE 50-250, Flowserve 3700, and KSB Etanorm API. Ideal for chemical transfer, reactor feed, boiler feed water, industrial circulation. Contact info@hyrig.com for datasheet and quote.

Conatct For Details
DetailReview(0)Additional

EAP-D50-250 OH2 Centrifugal Pump – Complete Specifications & Dimensions

The EAP-D50-250 is a horizontal, single-stage, single-suction, centerline-mounted overhung centrifugal pump designed and manufactured according to API 610 (ISO 13709) and GB/T 5656 standards. Ideal for medium-to-high head chemical transfer, reactor feed, industrial circulation, and boiler feed water applications.

EAP-D50-250 Specifications

  • Model: EAP-D50-250

  • Inlet DN: 50 mm

  • Impeller Diameter: 250 mm

  • Flow Range: 36 – 576 m³/h

  • Head Range: 15 – 200 m

  • Speed: 2900 / 1450 r/min

  • Design Pressure: ≤ 2.5 MPa

  • Temperature Range: -40°C to +200°C

  • Structure: OH2 centerline-mounted

  • Design Standard: API 610 (11th/12th edition), GB/T 5656

  • Material Options: Carbon steel, stainless steel (304/316L), corrosion-resistant alloys

Key Features

  • OH2 centerline-mounted design – Minimizes thermal distortion and vibration for continuous heavy-duty service

  • Back pull-out construction – Disassemble rotating element without removing piping or motor, reducing downtime

  • Impeller with back vanes – Effectively reduces axial thrust

  • Single volute casing – Balances radial force, lowers vibration

  • Heavy-duty bearings – Bearing life exceeds 17,500 hours

  • API 682 compatible seal chamber – Supports single/double/cartridge mechanical seals

  • External impeller clearance adjustment – Quick calibration without disassembly

  • Corrosion allowance design – Long-term operation in aggressive environments

International Brand Cross-Reference

EAP-D50-250 is a direct drop-in replacement for:

  • Sulzer PRE 50-250

  • Flowserve 3700 series (equivalent size)

  • KSB Etanorm API 50-250

Same mounting dimensions, same hydraulic performance, no pipeline or foundation modification required.

Typical Applications

  • Chemical industry – Solvent and acid transfer, reactor feed and discharge, chemical intermediate circulation

  • Water supply & drainage – Industrial water boosting, high-pressure water transfer

  • Heating & thermal – High-temperature hot water circulation, boiler feed water

  • General industry – Lubricating oil transfer, cooling system circulation

Media Compatibility

Optimized flow channels for clean or trace particle-containing media:

  • Neutral water, oil products, organic solvents

  • Weakly corrosive media

  • Materials: carbon steel, stainless steel, corrosion-resistant alloys

Sealing & Flange Options

  • Seal configuration: API 682 compliant mechanical seals (single/double/cartridge)

  • Flange standards: Class 150 / Class 300, fully compatible with international OH2 pump interfaces

EAP-D50-250 Dimensions and Installation

  • Suction flange: DN50 (2 inch)

  • Discharge flange: DN50 (2 inch)

  • Baseplate mounting: Standard API 610 OH2 footprint

  • Shaft height: Same as Sulzer PRE and Flowserve 3700 equivalents

  • Coupling guard included

Frequently Asked Questions – EAP-D50-250

Q: What is the maximum head of EAP-D50-250?
A: 200 meters at 2900 r/min. Lower speeds available for reduced head requirements.

Q: Can EAP-D50-250 handle high-temperature fluids?
A: Yes, up to 200°C with appropriate material and seal selection.

Q: Does EAP-D50-250 directly replace Sulzer PRE 50-250?
A: Yes. It is a dimensionally and hydraulically compatible drop-in replacement.

Q: What is the bearing life?
A: Over 17,500 hours under normal operating conditions.

Q: What materials are available?
A: Carbon steel (standard), stainless steel (304/316L), and corrosion-resistant alloys upon request.

Q: What mechanical seal options are available?
A: API 682 single cartridge mechanical seal as standard. Double seals and API 682 seal plans (Plan 11, 21, 23, 52, 53A, 54) available on request.

Q: What is the lead time for EAP-D50-250?
A: Standard lead time 3-4 weeks. Express options available for urgent replacements.

Related Models

  • EAP-D50-315 (higher head, same flow range)

  • EAP-D40-250 (lower flow, same head)

  • EAP-D80-250 (higher flow, similar head)

  • View all EAP-D series models

Why Choose EAP-D50-250

  • API 610 compliance – high reliability for continuous operation

  • OH2 centerline-mounted structure – low vibration, long life

  • Back pull-out design – reduced maintenance downtime

  • Heavy-duty bearings – over 17,500 hours life

  • External impeller clearance adjustment – easy calibration

  • Cost-effective alternative to international brands

Contact Us

For price, datasheet, cross-reference confirmation, or technical support:

Email: info@hyrig.com

Our engineering team responds within 24 hours with a quote and recommendations.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit