Ethylbenzene/Styrene Splitter Bottom Pump – 57.7m Head & 364.6 m³/h Flow | API 610 OH2 Pump
Product Description
The Ethylbenzene/Styrene Splitter Bottom Pump (also referred to as EB/SM Splitter Bottom Pump, Ethylbenzene/Styrene Column Bottom Pump, or EB/SM Column Bottoms Pump) is an API 610 OH2 single‑stage overhung centrifugal pump designed for crude styrene bottom service in the ethylbenzene/styrene separation tower of styrene monomer production units. It delivers a head of 57.7 meters at a flow rate of 364.6 m³/h, handling crude styrene with a density of 812 kg/m³ at 119.5°C.
Key operating parameters:
Flow rate: 364.6 m³/h
Head: 57.7 m
Medium: Crude styrene
Density: 812 kg/m³
Temperature: 119.5 °C (inlet/outlet)
Suction pressure: –0.01 MPa G (slight vacuum) / Discharge pressure: 0.45 MPa G
NPSHa (effective suction head): 5.3 m – challenging low‑NPSH condition
Pump type: API 610 OH2
Engineered for EB/SM splitter column bottom drainage in styrene plants, this OH2 pump reliably handles crude styrene under slight vacuum suction (–0.01 MPa G) and limited NPSHa (5.3 m) at elevated temperature (119.5°C). The back pull‑out design enables easy maintenance without disturbing piping, making it ideal for continuous bottom pump duty on the critical ethylbenzene/styrene separation tower.
Model variants available (naming conventions):
EB/SM‑BP (BP = Bottom Pump, concise and clear, recommended)
EBS‑BP (EBS = Ethylbenzene/Styrene, avoids slash character)
EB/SM‑P (general pump tag, without “bottom” function – not recommended alone)
2040‑P‑XXXA/S (plant‑section + pump number + standby identifier – per project conventions e.g., North Huajin)
DA‑401‑P‑XXX (common tower tag DA‑401 for EB/SM splitter)
Hyrig specializes in supplying API 610 standard process centrifugal pumps (OH2, BB2, BB5, VS6). Our core strength lies in providing complete drop‑in replacements for world‑leading brands such as Sulzer, Flowserve, and ITT Goulds – including Sulzer (OHH, OHHL, BBS, CD, CP, GSG, SJD‑API), Flowserve (HPX, HDX, HED‑DS, CSB, HDB, HSB, VCP, VCT), and Goulds (3700, 3700 LFI, 3640, 3620, 7200CB, VICR, VIC) pumps. All replacements deliver identical performance, quality, and standard compliance, with better cost‑effectiveness and shorter delivery times, offering efficient and economical fluid handling solutions for industrial applications.
For inquiries, please contact us at: info@hyrig.com