A garden pressure system (also called a garden booster pump set or automatic pressure pump) is a complete, ready‑to‑install unit that delivers constant, reliable water pressure for garden irrigation, hose watering, and even small household supply. Unlike a standalone pump that requires manual switching, the pressure system includes a pressure tank, pressure switch, and gauge – creating an automatic system that starts when a tap opens and stops when the tap closes.
This system is ideal for homeowners who rely on rainwater tanks, shallow wells, or low‑pressure mains water. It eliminates the frustration of weak sprinklers, slow‑filling hoses, and inconsistent irrigation. The built‑in pressure tank stores a small volume of pressurised water, preventing the pump from cycling on and off rapidly every time a tap is cracked open.
The system consists of three main components:
Self‑priming jet pump – Draws water from the source (tank, well, or mains) and pressurises it.
Pressure switch – Senses discharge pressure. Set to cut in at 1.5 bar (22 psi) and cut out at 3 bar (43 psi) – adjustable.
Small pressure tank (2–5 litres) – Cushions the system, absorbs water hammer, and prevents short cycling.
Operation cycle:
When a tap is closed, the pump stops when pressure reaches cut‑out setting.
The tank holds water at that pressure.
When a tap opens, pressure drops; the switch activates the pump.
Pump runs, supplying water until the tap closes and pressure recovers.
This automation means water is available instantly at consistent pressure, without the user needing to turn the pump on and off.
| Parameter | Typical Range |
|---|---|
| Maximum flow | 3.0 – 5.5 m³/h (50 – 92 L/min) |
| Maximum head (pressure) | 35 – 55 m (3.5 – 5.5 bar / 50 – 80 psi) |
| Suction lift | Up to 8 m (vertical lift from water surface) |
| Motor power | 0.5 – 1.5 HP (0.37 – 1.1 kW) |
| Voltage / frequency | 220‑240V / 50Hz or 110‑120V / 60Hz |
| Inlet / outlet size | 1″ × 1″ or 1.25″ × 1″ (25mm or 32mm) |
| Pressure tank volume | 2 – 8 litres (pre‑charged diaphragm type) |
| Pressure switch range | 1 – 4 bar (factory set 1.5‑3.0 bar) |
| Liquid temperature | 0 – 40°C |
| Enclosure protection | IP44 – IP54 |
| Self‑priming time | ≤60 seconds (at 5 m lift) |
| Component | Material / Type | Function |
|---|---|---|
| Pump | Cast iron or stainless steel jet pump | Moves water from source |
| Motor | Copper winding, thermal overload protected | Drives pump |
| Pressure tank | Steel with butyl diaphragm, pre‑charged | Stores pressurised water, prevents cycling |
| Pressure switch | Mechanical (micro‑switch) | Starts/stops pump based on pressure |
| Pressure gauge | Glycerin‑filled (optional) or dry | Shows system pressure |
| Base plate | Epoxy‑coated steel or plastic | Mounts all components |
| Priming plug | Brass or plastic | For filling pump with water before first use |
| Check valve (built‑in or external) | Brass or plastic | Prevents backflow when pump stops |
Some models integrate the pressure tank directly onto the pump housing for a very compact footprint. Others have a separate tank connected by a short flexible hose.
| Component | Standard Material | Premium Option |
|---|---|---|
| Pump casing | Cast iron with epoxy coating | Stainless steel 304 |
| Impeller | Brass or engineered plastic | Stainless steel |
| Diffuser / ejector | Brass or engineered plastic | Stainless steel |
| Pressure tank | Steel with epoxy paint | Stainless steel (for drinking water) |
| Diaphragm | Butyl rubber (sanitary) | – |
| Shaft | Stainless steel (AISI 304) | AISI 316 |
| Mechanical seal | Carbon / ceramic / NBR | Silicon carbide / Viton |
For rainwater collection (slightly acidic or containing tannins), stainless steel versions offer better long‑term corrosion resistance. For most garden applications, cast iron with epoxy coating is durable and cost‑effective.
| Application | Description |
|---|---|
| Rainwater tank supply | Pump from underground or above‑ground tank to garden hose, sprinklers, or toilet |
| Shallow well water | Draw from wells up to 8 m deep for garden irrigation |
| Low mains pressure boosting | Increase pressure to run sprinklers or multiple hoses simultaneously |
| Small household supply | Supply water to a cabin, garage, or outbuilding from tank or well |
| Greenhouse irrigation | Maintain constant pressure for drip systems or misters |
| Car washing | Provide strong, consistent spray |
| Farm / livestock watering | Deliver water to troughs from storage tanks |
Fully automatic – No manual start/stop. Pump turns on when water is needed, off when not.
Constant pressure – Pressure tank and switch maintain steady flow without severe fluctuations.
Self‑priming – Draws water up to 8 m vertically from tanks or wells.
Built‑in thermal protection – Motor automatically shuts off if overheated (dry run, blocked intake).
Corrosion‑resistant – Epoxy‑coated cast iron or stainless steel for long outdoor life.
Quiet operation – Jet pump design with rubber feet reduces vibration and noise.
Complete package – Pump, tank, switch, gauge, base plate, and sometimes flexible hoses – ready to connect.
Easy maintenance – Accessible priming plug, replaceable mechanical seal, and strainer.
Dry‑run prevention – Pressure switch stops pump if suction is lost (pressure falls below cut‑in).
Compact footprint – Fits under a bench, in a well house, or beside a rain tank.
Location – Place system on a solid, level, dry base, protected from rain and direct sun. Allow air circulation.
Suction pipe – Use rigid PVC or metal pipe (same size as pump inlet). Keep short, with minimal elbows. Slope slightly upward to pump. Install foot valve and strainer in the water source (well or tank).
Discharge pipe – Connect to garden hose, irrigation line, or house plumbing. Use a union for easy disconnection.
Electrical – Plug into a weatherproof socket with RCD/GFCI protection. Use a dedicated circuit.
Priming – Remove priming plug, fill pump casing and suction pipe with water until full, replace plug. Do not run dry – even a few seconds damages the seal.
Start‑up – Open a tap, plug in pump. It should prime within 60 seconds and deliver water.
Adjust pressure switch if needed – Turn nut on larger spring to change cut‑in/out range.
| Requirement | Action |
|---|---|
| Increase cut‑in AND cut‑out together | Turn large nut clockwise |
| Decrease cut‑in AND cut‑out together | Turn large nut anticlockwise |
| Widen differential (increase cut‑out only) | Turn small nut clockwise |
| Narrow differential (decrease cut‑out only) | Turn small nut anticlockwise |
Factory setting (1.5 cut‑in, 3.0 bar cut‑out) is suitable for most garden and irrigation. Do not exceed pump’s maximum pressure rating.
| Task | Frequency | Instructions |
|---|---|---|
| Clean suction strainer | Every 3‑6 months | Remove foot valve; rinse mesh |
| Check pressure tank air charge | Every 6 months | With pump off and pressure zero, use tyre gauge on tank valve. Pre‑charge should be 0.2 bar below cut‑in pressure (e.g., 1.3 bar for 1.5 bar cut‑in). Pump air if needed. |
| Inspect for leaks | Monthly | Look at pump shaft seal, pipe joints, tank valve |
| Winterisation (freezing areas) | Before freeze | Drain pump, tank, and pipes completely; store indoors if possible; or use electric heat tape and insulation. |
| Mechanical seal replacement | When leaking | Remove pump housing; replace seal kit (carbon/ceramic). |
If the pump cycles rapidly (on/off every few seconds), the pressure tank is likely waterlogged (lost air charge). Re‑pressurise the tank.
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump does not start | No power, pressure switch stuck, thermal trip | Check outlet, breaker; press reset on motor; test switch |
| Pump runs but no water | Loss of prime, air leak on suction, foot valve stuck | Re‑prime; check suction joints; clean foot valve |
| Pump cycles on/off rapidly | Waterlogged pressure tank, system leak, faulty switch | Re‑pressurise tank; fix leaks; replace switch |
| Low pressure (pump runs continuously) | Clogged impeller or strainer, worn pump, low water supply | Clean impeller; check suction pipe; well may be low |
| Pump hums but does not run | Seized impeller, bad capacitor (single‑phase) | Clean obstruction; replace capacitor |
| Noisy operation | Cavitation (restricted suction) , loose base, worn bearings | Check suction pipe size; tighten mounting bolts; replace pump if bearings worn |
| Component | Recommended Quantity |
|---|---|
| Mechanical seal kit | 1 set |
| Pressure switch | 1 |
| Pressure tank (2‑5L) | 1 (if waterlogged) |
| Foot valve with strainer | 1 |
| Impeller (complete) | 1 |
| Capacitor (single‑phase motor) | 1 |
All‑in‑one automatic package – Ready to install, no separate components to source.
High‑quality components – Reliable jet pump, certified pressure switch, pre‑charged diaphragm tank.
Energy efficient – Pump only runs when water is demanded, not continuously.
Constant garden water pressure – Enjoy effective sprinklers, fast‑filling hoses, and multiple outlets.
Self‑priming from tanks/wells – No need for a below‑floor pump pit.
Easy to move – Compact design allows seasonal relocation (e.g., from rain tank to well).
Comprehensive protection – Thermal cutout, dry‑run prevention via low‑pressure switch cut‑off.
2‑year warranty – Standard coverage with extended option.
For detailed selection of the correct garden pressure system for your application – including water source (tank, well, mains), required flow, lift height, and desired pressure – please contact our engineering team.
Email: info@hyrig.com
Our engineers support home and garden water supply projects worldwide with reliable, automatic garden pressure systems – delivering constant water pressure for irrigation, hose, and household use.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.