HYRIG can supply the S series cartridge check valves. The S6K1 is a size 6 direct-acting cartridge valve designed for installation into a manifold block. It allows free flow in one direction and provides leak-free blocking in the reverse, rated up to 31.5 MPa.
Data source: Technical data table.
| Parameter | S6K1 |
|---|---|
| Max Flow | 40 L/min |
| Cavity | Size 6 standard cavity |
Typical Ordering Code Examples:
S6K1-301889 : Size 6, 0.05 MPa opening pressure, straight-through.S6K1-301910 : Size 6, 0.5 MPa opening pressure, straight-through.S6K2-301889 : Size 6, 0.05 MPa opening pressure, right-angle.The cartridge consists of a sleeve, poppet, and spring. It is inserted into a machined cavity and sealed with O-rings. Forward flow lifts the poppet; reverse flow seats it. This design minimizes space requirements and eliminates external piping leaks.
Replacing an existing S6K1 cartridge? Verify the cavity dimensions and the opening pressure code. If your current part number ends in -301889, it corresponds to a 0.05 MPa opening pressure. If it ends in -301910, it is 0.5 MPa. Always confirm the suffix against the original nameplate.
Used in hydraulic integrated circuits (manifolds) for pump isolation, load holding, and directional control.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
HYRIG can supply replacement seal kits (O-rings and backup rings) for the S6K1 cartridge.
Need a different cartridge size? Explore the S10K1 Cartridge Check Valve or view the full Hydraulic Check Valves range.
What does the -301889 suffix mean?
It is a manufacturing series code. For the S6K1, -301889 typically denotes a straight-through cartridge with a 0.05 MPa (code 1) opening pressure.
Does this valve require a separate cover plate?
No, cartridge check valves are fully contained within the manifold cavity and do not require a cover plate.
Can I replace an S6K2 with an S6K1?
S6K1 is a straight-through type, while S6K2 is a right-angle type. They use the same cavity but have different flow paths. Verify your manifold schematic before substituting.
For S6K1 cartridge valve selection and ordering code verification, contact HYRIG: info@hyrig.com