HYRIG can supply the SV series hydraulic pilot-operated check valves. The SV30 is a size 30 seat-type valve designed for leak-free blocking in the reverse direction. It is rated for 31.5 MPa and does not have a drain port.
Data source: Technical data table.
| Parameter | SV30 |
|---|---|
| Max Flow | 500 L/min |
| Pilot Ratio | 1 : 3.6 |
| Weight | 9.5 kg |
Typical Ordering Code Examples:
SV30PA1-30B/ : Size 30, pilot operated, without drain port, series 30B.Free flow is allowed from A to B. Reverse flow is blocked by the spring-loaded main poppet. Pilot pressure at port X mechanically opens the poppet. Without a drain port, pressure at port A acts on the control piston, increasing the required pilot pressure.
Replacing an SV30? Confirm the mounting pattern and port sizes. The required pilot pressure is determined by the load pressure and the 1:3.6 pilot ratio. Ensure your system does not exceed the 31.5 MPa rating.
Used for load holding, preventing load drop in case of pipe rupture, and isolating pressure circuits in heavy machinery.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
HYRIG can supply replacement O-rings and seal kits for the SV30 valve.
Need a drain port to reduce pilot pressure? Explore the SL30 Hydraulic Pilot Check Valve. You can also view the Hydraulic Pilot Check Valves overview.
1. What is the pilot ratio of the SV30?
The pilot ratio is 1:3.6. The pilot pressure must be at least 1/3.6 of the load pressure to open the valve.
2. What is the maximum flow for SV30?
It is rated for flows up to 500 L/min.
3. What is the difference between SV30 and SL30?
The SV30 lacks a drain port, meaning pressure at port A affects the control piston. The SL30 has a drain port (Y) to isolate this pressure.
For SV30 hydraulic pilot check valve selection and spare parts, contact HYRIG: info@hyrig.com