Selecting the correct packing element for a Hydril GK Annular BOP depends on the well environment, operating temperature, and fluid composition. This guide outlines the criteria for choosing between Natural and Nitrile compounds, and distinguishes the GK from other Hydril annular models.
| Condition | Action |
|---|---|
| You are operating in standard temperatures (up to 180°F / 82°C) without H₂S | Select the Natural Rubber packing element for optimal elasticity and sealing on irregular shapes. |
| The well contains H₂S, CO₂, or requires higher abrasion resistance | Select the Nitrile (NBR) packing element with NACE MR0175 compliance. |
| Your BOP nameplate says 'GL' or 'GX' instead of 'GK' | Do not order GK elements. The internal profiles and insert geometries are different. Contact HYRIG for GL/GX matching. |
| The packing element is leaking after closing on pipe | Verify the operating pressure is correct, inspect the element for tears, and check if the Piston (Item 3) or Slotted Sleeve (Item 4) is excessively worn. |
Common field error: Installing a packing element without applying a generous coating of silicone or BOP grease to the bore and the element itself. Dry installation causes the elastomer to bind, leading to pinching, tearing, and premature failure on the first closure.
Email info@hyrig.com with:
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.