The LNG Bunkering Submerged Pump is a high-performance vertical, multistage centrifugal pump specifically engineered for ship-to-ship LNG bunkering, ship-to-shore transfer, and marine fuel gas supply systems (FGSS). Designed for cryogenic service at temperatures as low as -196°C, this pump is the preferred solution for the safe and efficient transfer of liquefied natural gas (LNG) in the marine environment.
The pump and motor are combined as a single, compact unit and fully submerged in the LNG. This unique design eliminates rotating shaft seals, providing absolute zero leakage of volatile LNG and removing the potential for ignition. The motor is cooled and lubricated by the LNG itself, ensuring ultra-high reliability and a long service life. The pump operates with reduced noise emission, below 80 dB(A), suitable for marine environments.
Fully Submerged, Seal‑Less Design – The pump and motor are completely immersed in the cryogenic liquid, eliminating dynamic mechanical seals for absolute zero leakage. The motor operates in an oxygen-free environment, removing the potential for ignition.
Helical Inducer for Ultra-Low NPSH – Equipped with a specially designed helical inducer that significantly reduces Net Positive Suction Head requirements (NPSHr), enabling reliable operation even at low liquid levels and preventing cavitation.
Multistage High-Head Capability – Available in single-stage and multistage configurations (2, 3, 4, or 6 stages) to meet diverse head and flow requirements. Flow rates range from 1 m³/h to over 546 m³/h depending on configuration. Differential pressure up to 55 bar for FSRU booster applications.
Automatic Axial Thrust Balancing – An automatic axial thrust balance mechanism minimizes bearing load for a prolonged service life.
High Efficiency – High pump efficiency, typically over 70%, due to reduced internal leakage, resulting in lower operating costs and reduced heat input into the fluid.
Permanent Magnet Motor Options – Available with highly efficient and compact permanent magnet motors, reducing the size and weight of the pump.
Vacuum-Insulated Construction – The pump is housed within a cryostat and vacuum insulated to efficiently minimize heat ingress and maintain the LNG at the required temperature.
VFD Compatibility – Motors are designed for variable frequency drive (VFD) operation, providing a wide speed range for precise flow and pressure control.
DNV Type Approved – Certified for installation on vessels classed by Det Norske Veritas.
Fluids Handled: LNG, LPG, Ethane, Ethylene, and other cryogenic liquids
Temperature Range: Down to -196°C
Flow Rate: 1 – 546+ m³/h
Differential Pressure: Up to 55 bar
Motor Power: 10 kW to 400+ kW
Number of Stages: 1, 2, 3, 4, or 6
Configuration: Vertical, submerged motor, multistage centrifugal
Mounting: In-tank, retractable, or cryosump installation
Design Standards: API 610, IGC Code, IEC Norms
Certifications: DNV type approved, ATEX, CCS
The LNG Bunkering Submerged Pump serves critical roles across the LNG marine sector:
Ship-to-Ship LNG Bunkering – Transferring LNG from bunker vessels to receiving LNG-powered ships
Ship-to-Shore LNG Transfer – Transferring LNG from onshore terminals to vessels
LNG Fuel Gas Supply Systems (FGSS) – Main or backup pumps for feeding gas to low-pressure marine engines, with differential pressure up to 20 bar
Spray Pumps and Stripping Pumps – Tank cooling and cargo stripping operations on LNG carriers and bunkering vessels
Small to Medium Cargo Pumps – Cargo transfer for small and medium LNG carriers
FSRU Booster Pumps – Differential pressure up to 55 bar for floating storage regasification units
LNG Bunkering Stations – On-water LNG bunkering stations built on barges or LNG fuel-powered ships
LNG Automotive Refueling Stations – Supplying LNG to one or two LNG dispensers
Zero Leakage Safety – The fully submerged, seal‑less design eliminates the primary leak path, ensuring safe handling of LNG in hazardous marine environments.
Ultra-Low NPSH – The helical inducer ensures reliable operation even at low liquid levels, preventing cavitation and maximizing tank utilization.
Exceptional Reliability – With LNG-lubricated bearings, integrated motor cooling, and robust cryogenic construction, the pump delivers reliable continuous operation with minimal maintenance.
Reduced Boil-Off Gas – Vacuum-insulated construction and submerged motor design minimize heat ingress, reducing boil-off gas and improving cargo retention.
Energy Efficiency – High hydraulic efficiency (over 70%) combined with VFD control and advanced permanent magnet motor technology minimizes power consumption.
Quick Start-Up – The pump remains constantly submerged in the cryogenic liquid, enabling immediate start-up without pre-cooling.
Low Maintenance – The absence of wear parts, minimized bearing load, and simple, lightweight structure ensure easy maintenance and long service life.
Proven Technology – Backed by decades of engineering expertise, with thousands of units operating reliably in LNG marine applications worldwide.