Our API 610 low pressure boiler blowdown pumps are available in BB, OH, and VS designs, specifically engineered for the reliable transfer of high‑temperature blowdown water from industrial boilers, heat recovery steam generators, and steam systems to flash tanks, heat recovery, or treatment facilities. BB pumps provide superior rotor stability for high‑flow, high‑pressure main blowdown duties. OH pumps offer compact solutions for smaller applications, while VS pumps handle low‑NPSH suction from blowdown sumps and collection tanks. Built with stainless steel, chrome‑moly, and high‑temperature alloys. Fully API 610/ISO 13709 compliant for long‑life, reliable boiler blowdown service.

Conatct For Details
DetailReview(0)Additional

Our API 610 low pressure boiler blowdown pumps are heavy‑duty centrifugal pumps engineered specifically for the reliable transfer of high‑temperature blowdown water from industrial boilers, heat recovery steam generators (HRSGs), and steam generation systems to flash tanks, heat recovery units, or treatment facilities. Boiler blowdown is the continuous or intermittent removal of water from the boiler to control dissolved solids, prevent scale formation, and maintain water chemistry within specification. The blowdown water is typically at elevated temperatures (up to 200°C) and may contain dissolved solids, chemicals, and corrosive components that demand pumps with exceptional thermal stability, reliable sealing, and robust construction.

Low pressure boiler blowdown pumps typically operate at discharge pressures below 2.5 MPa (25 bar), serving industrial boilers and auxiliary steam systems. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for reliable, continuous operation under severe conditions. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – with the BB2 type often preferred for main high‑temperature blowdown duties.

API 610 Classifications for Boiler Blowdown Duties

  • BB – Between Bearings Pumps
    For main high‑capacity boiler blowdown water transfer from blowdown tanks to flash vessels or treatment, BB pumps provide superior rotor stability and long‑term reliability. BB2 (radially split, single‑stage or two‑stage) configurations are commonly specified for flows from 20 to 1,500 m³/h and heads up to 250 metres. The between‑bearings arrangement minimises shaft deflection, extending seal and bearing life – critical for continuous, high‑temperature service. Centreline support accommodates thermal expansion.

  • OH – Overhung Pumps
    For moderate‑capacity blowdown transfer, booster duties, or smaller boiler systems, OH pumps offer a compact and cost‑effective solution. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes are widely used for blowdown water transfer from smaller boilers and auxiliary steam systems. Centreline mounting accommodates thermal expansion. Their back‑pull‑out design allows easy seal and impeller maintenance without disturbing piping. Single‑stage OH pumps handle flows up to 800 m³/h and heads up to 180 metres.

  • VS – Vertically Suspended Pumps
    In applications where blowdown water is drawn from low‑NPSH sumps, collection tanks, or underground blowdown vessels, VS pumps provide excellent suction performance. VS1 (vertical turbine) and VS4 (vertical sump) types submerge the impeller below the liquid level, eliminating cavitation and priming problems. Their vertical footprint saves valuable plot space in congested plant areas.

Key Performance & Design Features

  • Temperature Capability – Engineered for blowdown water temperatures up to 200°C (392°F), with appropriate material selection and thermal expansion allowances.

  • Flow & Head – Capacities from 5 m³/h to over 2,000 m³/h; heads typically from 20 to 250 metres.

  • Pressure Rating – Designed for discharge pressures up to 25 barg, matching low‑pressure blowdown system requirements.

  • Casing Design – Radially or axially split casings with heavy‑wall construction for pressure integrity; centreline support to accommodate thermal expansion.

  • Materials – Wetted parts in chrome‑moly steels (ASTM A217 WC6/WC9), stainless steels (304L, 316L), duplex, or high‑temperature alloys to resist hot water corrosion, thermal fatigue, and scaling.

  • Sealing – API 682 mechanical seals (single, dual, or tandem) with appropriate flush and cooling plans – typically Plan 23 (cooled seal chamber), Plan 32 (clean flush), or Plan 53 – to maintain seal integrity at elevated temperatures.

  • Thermal Expansion – Adequate internal clearances, expansion joints, and flexible coupling designs to accommodate significant temperature gradients during startup and operation.

  • Bearing & Lubrication – Heavy‑duty sleeve or rolling element bearings with forced oil, oil mist, or grease lubrication; bearing temperature and vibration monitoring for predictive maintenance.

  • Impeller Options – Closed impellers for efficient handling; special hydraulics to minimise cavitation and maintain efficiency at elevated temperatures.

  • Solids Handling – Robust impeller and casing designs to handle minor solids and scale particles present in blowdown water.

Typical Applications

  • Boiler blowdown water transfer to flash tanks and blowdown recovery systems

  • Continuous and intermittent blowdown from industrial boilers

  • Blowdown transfer from heat recovery steam generators (HRSGs)

  • Industrial boiler and steam system blowdown

  • Blowdown water transfer to heat recovery and treatment systems

  • Waste heat boiler blowdown pumping

Industries Served

  • Power generation (industrial and cogeneration plants)

  • Oil refineries and petrochemicals (process steam)

  • Chemical and fertiliser plants

  • Pulp and paper mills

  • Food and beverage processing

  • District heating and cogeneration facilities

Why Choose Our Low Pressure Boiler Blowdown Pumps?

With deep expertise in high‑temperature water handling and full API 610 compliance, we design and manufacture low pressure boiler blowdown pumps that deliver unmatched reliability, safety, and efficiency. Every pump undergoes rigorous hydrostatic testing, performance curve verification, mechanical running tests, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet the most stringent owner‑operator specifications. We offer customised hydraulic designs, material upgrades, and sealing arrangements tailored to your specific blowdown water properties, temperature, and operating conditions. Our engineering support includes API 684 rotor dynamics, thermal expansion analysis, and NPSH margin studies to ensure seamless, long‑term operation in the most demanding boiler blowdown services.

Contact Us

For technical datasheets, application engineering advice, or a project‑specific quotation, please contact us at:

info@hyrig.com

Trust our API 610 low pressure boiler blowdown pumps to keep your boiler systems running reliably and efficiently.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit