Our API 610 naphtha hydrogenation injection water pumps are heavy‑duty centrifugal pumps engineered specifically for high‑pressure wash water injection into naphtha hydrotreating reactors and reactor effluent streams. In naphtha hydrotreating units, hydrogen sulfide (H₂S) and ammonia (NH₃) generated during the reaction combine to form ammonium bisulfide (NH₄HS) salts at lower temperatures. These salts can precipitate and foul air coolers, heat exchangers, and downstream equipment, leading to reduced heat transfer, flow restriction, and accelerated corrosion. High‑pressure wash water is injected upstream of the air coolers to dissolve these ammonium salts, maintaining unit operability and protecting critical equipment.
The wash water is typically deaerated or demineralized water, injected at pressures matching the hydrotreater reactor effluent pressure – often up to 200 barg or higher. The injection flow rate is relatively low compared to main process streams, making this a demanding low‑flow, high‑head pumping application. Pumps for this service require exceptional pressure containment, corrosion resistance to handle sour water with H₂S and chlorides, and reliable performance under continuous operation. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for maximum safety, reliability, and longevity.
API 610 Classifications for Wash Water Injection Duties
BB5 Barrel‑Type Pumps (Preferred for Extreme High‑Pressure Injection)
For main high‑pressure wash water injection into naphtha hydrotreater effluent streams, the BB5 subtype (barrel‑type, double‑casing, multistage) is the preferred configuration for pressures exceeding 100 barg. The inner casing contains multistage impellers, while the heavy‑walled outer barrel provides absolute pressure containment – a critical safety feature. BB5 pumps deliver heads up to 3,500 metres and flows typically ranging from 30 to 750 m³/h. The double‑casing design, centreline mounting, and radial split construction enable rapid warm‑up and accommodate thermal expansion.
BB – Between Bearings Pumps
For medium‑pressure wash water injection and booster duties, BB pumps provide superior rotor stability and long‑term reliability. BB3 (axially split, multistage) and BB4 (radially split, ring‑section) configurations are specified for flows up to 1,500 m³/h and heads up to 2,000 metres.
OH – Overhung Pumps
For lower‑flow, high‑head wash water injection applications, OH pumps – particularly OH6 (integrally geared, high‑speed) and OH2 (horizontal, centreline‑mounted) subtypes – offer compact, space‑saving solutions. These pumps are well‑suited for services requiring heads up to 1,500 metres at flows below 100 m³/h. The Roto‑Jet® RO‑FT API 610 pump is a notable example specifically designed for low‑flow, high‑head services including naphtha wash water.
VS – Vertically Suspended Pumps
VS pumps are used for low‑NPSH suction from deaerated water storage tanks or sumps. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the impeller below the liquid level, eliminating cavitation and priming problems.
Key Performance & Design Features
Pressure Capability – Discharge pressures from 50 barg up to 450 barg, matching hydrotreater effluent pressures
Flow & Head – Capacities from 5 m³/h to 1,500 m³/h; multistage hydraulics generate heads up to 3,500 metres
Temperature Range – Engineered for water from ambient to 150°C, with appropriate material selection
Low‑Flow Capability – Specialised hydraulic designs (including Pitot tube, high‑speed, and multistage configurations) for efficient low‑flow, high‑head operation
Materials – Wetted parts in stainless steels (316L, duplex, super duplex), 12% chromium steels, and corrosion‑resistant alloys to withstand sour water (H₂S, chlorides). Full NACE MR0175/ISO 15156 compliance for sour service
Sealing – API 682 dual mechanical seals with Plan 53A/B/C or Plan 72/75/76 seal support systems for high‑pressure, sour water service
Casing Integrity – BB5 barrel casing designed to ASME Section VIII; hydrostatically tested at 1.5x maximum working pressure
Rotor Dynamics – Rigorous API 684 analysis ensures lateral and torsional critical speeds are well above the operating range
Bearing & Lubrication – Forced oil or oil mist lubrication with bearing temperature and vibration monitoring for predictive maintenance
NPSH Performance – Low NPSH3 designs available without inducers for demanding suction conditions
Typical Applications
Wash water injection upstream of naphtha hydrotreater air coolers (ammonium salt fouling prevention)
High‑pressure water injection into reactor effluent streams in catalytic reforming and hydrotreating units
Low‑flow, high‑head water injection in refinery and petrochemical processes
Deaerated water injection for corrosion control in high‑pressure systems
Wash water supply in naphtha hydrogenation and gasoline hydrotreating units
Industries Served
Oil refineries (naphtha hydrotreating, catalytic reforming, gasoline hydrogenation)
Petrochemicals (feed purification and hydroprocessing)
Gas processing (condensate hydrotreating)
Why Choose Our Naphtha Hydrogenation Injection Water Pumps?
With specialised expertise in high‑pressure water injection and full API 610 compliance, we design and manufacture naphtha hydrogenation injection water pumps that deliver best‑in‑class reliability, safety, and efficiency. Every pump undergoes rigorous hydrostatic testing at 1.5x maximum working pressure, performance curve verification, mechanical running tests, and comprehensive NDT inspections (radiographic, ultrasonic, magnetic particle, dye penetrant) with full documentation to meet the most stringent owner‑operator specifications. We provide full engineering support – including API 684 rotor dynamics analysis, NPSH margin calculations, sour water material evaluation, and seal system design – to ensure seamless integration into your naphtha hydrogenation unit. All materials are supplied with complete traceability and certified test reports.
Contact Us
For technical datasheets, API 684 analysis reports, or a project‑specific quotation, please contact us at:
info@hyrig.com
Partner with us to protect your naphtha hydrotreater air coolers with reliable, code‑compliant API 610 wash water injection pump technology.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.