PARKER RDM/RM Sandwich Relief Valve Series
Overview:
HYRIG can supply the PARKER RDM and RM series and related hydraulic components. These direct-operated piston-type valves are designed for sandwich mounting between directional valves and manifold blocks.
| Model Code | Size | Function | Max Pressure (P/A/B) | Max Pressure (T) | Max Flow |
|---|---|---|---|---|---|
| RDM2PT | NG06 | P → T | 350 bar | 50 bar | 40 L/min |
| RDM2TT | NG06 | T → T | 350 bar | 50 bar | 40 L/min |
| RM2AT | NG06 | A → T | 350 bar | 50 bar | 40 L/min |
| RDM3PT | NG10 | P → T | 315 bar | 10 bar | 80 L/min |
| RM3PT | NG10 | P → T | 315 bar | 10 bar | 80 L/min |
Data source: PARKER catalog MSG14-2500.
For the specific NG06 P-line valve, view PARKER RDM2PT Sandwich Relief Valve.
| Parameter | RDM2/RM2 (NG06) | RDM3/RM3 (NG10) |
|---|---|---|
| Mounting Standard | ISO 4401-03 (CETOP 3) | ISO 4401-05 (CETOP 5) |
| Mounting Bolt Pattern | 4 × M5 | 4 × M6 |
| Weight (approx.) | 1.3 kg | 2.6 kg |
When replacing a RDM/RM series valve, verify the mounting size (NG06 vs NG10) and the pressure range code (e.g., 02, 06, 16, 21, 35 for NG06). The sandwich footprint is standardized, but the pressure spring must match the system requirement.
Not sure whether you need RDM2PT or RM3AT? Tell us your circuit requirements (P, A, or B line relief), and HYRIG will confirm the correct model code.
Used in hydraulic manifolds requiring compact pressure limitation in the P, A, or B lines, often between a directional valve and a manifold block.
Disclaimer: PARKER is a registered trademark of Parker Hannifin Corporation. HYRIG is an independent supplier of hydraulic components and is not affiliated with Parker Hannifin Corporation.
Specifications:
Contact Us:
For PARKER RDM/RM series selection, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.