Our API 610 quench water pumps are heavy‑duty centrifugal pumps engineered specifically for circulating high‑temperature quench water in ethylene plants, refineries, and petrochemical facilities. In ethylene production, the quench water system is a critical component directly connecting the cracking and compression units. The quench water pump draws quench water from the quench water tower and delivers it to various heat exchangers to recover heat and cool the quench water, serving as the driving force for quench water circulation.
The quench water is typically at elevated temperatures (up to 83‑90°C), and the pump must handle high flow rates with reliable, continuous operation. As a critical piece of equipment in the quench system, the reliability and performance of the quench water pump have a significant impact on the overall performance of the ethylene plant. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for maximum reliability and longevity.
API 610 Classifications for Quench Water Duties
BB1 – Between Bearings Pumps (Preferred for Main Quench Water Circulation)
For main high‑capacity quench water circulation, the BB1 subtype (axially split, single‑stage, double‑suction, between‑bearings) is the preferred configuration. The axially split casing allows easy maintenance without disturbing piping, while the double‑suction impeller balances axial thrust and provides efficient, low‑NPSH operation. The between‑bearings arrangement provides exceptional rotor rigidity, minimising shaft deflection and vibration. BB1 pumps handle high flows (up to 18,000 m³/h) at heads up to 260 metres. BB1 pumps are widely specified for quench water service in large‑capacity ethylene plants.
BB – Between Bearings Pumps
For high‑capacity quench water transfer and circulation duties, BB pumps provide superior rotor stability and long‑term reliability. BB2 (radially split, single‑stage) configurations are also specified for quench water circulation in ethylene plants.
OH – Overhung Pumps
In quench water systems, OH pumps are typically employed for smaller circulation loops, booster duties, or auxiliary services where flows are lower. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes provide compact, cost‑effective solutions for auxiliary roles. Centreline mounting ensures thermal expansion does not misalign the pump and driver.
VS – Vertically Suspended Pumps
VS pumps are used where the quench water system has very low NPSH or where floor space is limited. VS1 (vertical turbine) and VS4 (vertical sump) types are utilised for sump duties and tank transfer applications.
Key Performance & Design Features (BB1 Focus)
Temperature Capability – Engineered for quench water temperatures up to 90°C (194°F) and above
Flow & Head – Capacities from 50 m³/h to over 18,000 m³/h; heads typically from 50 to 260 metres
Casing Design – Axially split casing with heavy‑wall construction for pressure integrity; double‑volute design minimises shaft deflection
Double‑Suction Impeller – Balanced axial thrust, efficient operation, low NPSH, and quiet operation
Materials – Wetted parts in carbon steel, stainless steels (304L, 316L), duplex, and high‑temperature alloys. All API 610 material classes (S‑4, S‑5, S‑6, S‑8, A‑8, D‑1, D‑2) available
Sealing – API 682 mechanical seals with appropriate flush plans (Plan 11, 13, 23, 32, 53A/B) – typically Plan 23 for quench water service
Bearing & Lubrication – Heavy‑duty bearing combinations (ball‑ball, sleeve‑ball, tilting‑pad) with fan or water cooling options
Rotor Dynamics – Rigorous API 684 analysis ensures lateral and torsional critical speeds are well above the operating range
Shaft Design – Large diameter shaft with close bearing spacing minimises deflection and extends mechanical seal life
API 610 Compliance – Full compliance with API 610 latest edition (currently 12th edition)
Typical Applications
Quench water circulation in ethylene plant quench water towers
Quench water transfer to heat exchangers for heat recovery
Quench water recirculation in refinery and petrochemical units
High‑temperature water circulation in cooling systems
Process water circulation in gas cooling and compression trains
Industries Served
Petrochemicals (ethylene plants, olefin production)
Oil refineries (cracking units)
Chemical processing (gas cooling systems)
Why Choose Our Quench Water Pumps?
With deep expertise in high‑temperature water handling and full API 610 compliance, we design and manufacture quench water pumps that deliver unmatched reliability, safety, and efficiency. Every pump undergoes rigorous hydrostatic testing, performance curve verification, mechanical running tests, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet the most stringent owner‑operator specifications. We offer customised hydraulic designs, material upgrades, and sealing arrangements tailored to your specific quench water composition, temperature, and flow requirements. Our engineering support includes API 684 rotor dynamics, thermal expansion analysis, and NPSH margin studies to ensure seamless, long‑term operation in the most demanding quench water services.
Contact Us
For technical datasheets, application engineering advice, or a project‑specific quotation, please contact us at:
info@hyrig.com
Trust our API 610 quench water pumps to keep your ethylene plant quench system running reliably and efficiently.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.