1. Product Overview
The OH2 Series Sour Water Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 (ISO 13709) international standards. It is purpose-built for demanding industrial applications such as oil refining, petrochemical processing, coal chemical industry, and natural gas treatment. This pump is specifically engineered to handle sour water containing acid gases (H₂S, NH₃), salts (Cl⁻, SO₄²⁻), and trace solid particles. It is designed for highly corrosive, medium-to-high temperature, cavitation-prone, and continuous operation, making it a critical fluid transfer device in sour water degassing and stripping regeneration systems.
Model Code Interpretation (OH2):
O = Overhung: Impeller is positioned outside the bearing housing – compact structure, reducing localized corrosion from sour water stagnation.
H = Horizontal: Horizontal mounting, compatible with pipeline layouts of sour water strippers, heat exchangers, buffer tanks, and related equipment.
2 = 2nd Generation: Centerline support design (vs. foot-mounted OH1) – superior thermal stability for temperature fluctuations (typically 60–120°C) and pressure surges during sour water transfer.
2. Key Structural Features
Centerline Mounting: Pump casing is supported along the horizontal centerline. Over a wide temperature range (-80°C to +450°C), thermal expansion/contraction maintains perfect shaft alignment, avoiding equipment wear and seal failure caused by sour water temperature fluctuations, thus extending service life (industrial requirement ≥8,000 continuous operating hours).
Radially Split Casing: The casing splits vertically. Maintenance can be performed without removing inlet/outlet piping – the "back pull-out" design allows rotor assembly extraction, drastically shortening downtime and ensuring continuous sour water stripping system operation, reducing environmental risks (sour water leakage can cause air/soil pollution).
Single-Stage Overhung + Optimized Flow Path: Single impeller + single bearing housing – the flow path uses bionic curved design, smooth and dead‑free, reducing deposition and clogging from salt crystallization (e.g., NH₄Cl, (NH₄)₂S) and solid particles in sour water. The impeller inlet features an inducer structure to reduce Net Positive Suction Head required (NPSHr), adapting to the cavitation‑prone nature of sour water.
API 682 Anti-Corrosion Sealing System: Standard cartridge double mechanical seals. Supports Plan 53B/62 flush plans (anti‑crystallization, anti‑corrosion). Leakage ≤10 ppm. Friction pairs use silicon carbide (SiC) + antimony‑impregnated carbon, with Hastelloy‑lined metal parts – fully compatible with highly corrosive sour water environments, preventing equipment corrosion and safety incidents from seal failure.
3. General Technical Specifications (Industry Standard Range)
Capacity: 3 – 2,600 m³/h (customizable up to 3,000 m³/h)
Head: 30 – 395 m (max. 1,300 ft)
Operating Temperature: -80°C to +450°C (-150°F to +842°F); typical sour water service: 60–120°C (stripper bottom outlet up to 140°C)
Operating Pressure: Standard 50 bar (725 psi); customizable up to 100 bar (1,450 psi) for sour water stripping system requirements
Speed: 50Hz: 1,500/3,000 rpm; 60Hz: 1,800/3,600 rpm
Flange Rating: Class 150/300/600# (RF sealing face, ASME B16.5) – flange material matches pump body for corrosion resistance
Material Options: Duplex steel (2205/2507/S25073 – mainstream recommendation, excellent pitting/crevice corrosion resistance), Hastelloy (C276/C22), Monel 400, and NACE MR0175/ISO 15156 sour service / corrosion resistant materials for high Cl⁻, high H₂S sour water.
4. Global Equivalent Models (API 610 OH2 for Sour Water)
Sulzer OHH series (OHH25-200, OHH40-250, OHH80-400): Capacity 25–400 m³/h, Head 50–370 m – sour water degassing system dedicated, anti‑crystallization flow path design
Flowserve HPX series (HPX310, HPX410, HPX510): Capacity 50–2,000 m³/h, Head 40–350 m – optimized for high‑H₂S sour water, upgraded seal anti‑corrosion
CPC HR/HOR series (HR150-300, HOR200-350): Capacity 100–2,272 m³/h, Head 50–395 m – for large integrated refining & petrochemical sour water stripping systems
Rodelta HZC series (HZC50-250, HZC80-315): Capacity 50–1,920 m³/h, Head 30–380 m – standard duplex steel construction, enhanced Cl⁻ corrosion resistance
Amarinth OH2 series (custom Hastelloy models): Capacity 10–500 m³/h, Head 40–250 m – designed for offshore platform high‑salinity, highly corrosive sour water
KSB KZE series (KZE80-200, KZE100-315): Capacity 30–200 m³/h, Head 50–160 m – API 610 12th edition compliant, suitable for sour water regeneration circulation
5. Complete OH2 Sour Water Pump Model Lineup (20 Core Models for Selection)
Model: Sour Water Pump 40-250 OH2
Definition: API 610 OH2, DN40 outlet, 250mm impeller – sour water dedicated
Capacity/Head: 25–50 m³/h / 80–110 m
Typical Application: Small refinery sour water transfer, degassing tank feed booster pump
Model: Sour Water Pump 50-160 OH2
Definition: API 610 OH2, DN50 outlet, 160mm impeller – sour water general purpose
Capacity/Head: 30–60 m³/h / 35–50 m
Typical Application: Small/medium refinery sour water stripping system, heat exchanger feed pump
Model: Sour Water Pump 50-200 OH2
Definition: API 610 OH2, DN50 outlet, 200mm impeller – sour water standard
Capacity/Head: 30–65 m³/h / 50–70 m
Typical Application: Natural gas processing plant sour water transfer, buffer tank reflux pump
Model: Sour Water Pump 50-250 OH2
Definition: API 610 OH2, DN50 outlet, 250mm impeller (high pressure) – sour water high pressure
Capacity/Head: 30–65 m³/h / 80–115 m
Typical Application: High pressure sour water stripping system, long-distance booster pump
Model: Sour Water Pump 65-160 OH2
Definition: API 610 OH2, DN65 outlet, 160mm impeller (medium flow low pressure)
Capacity/Head: 50–100 m³/h / 32–48 m
Typical Application: Large refinery sour water circulation, stripper feed pump
Model: Sour Water Pump 65-200 OH2
Definition: API 610 OH2, DN65 outlet, 200mm impeller (general purpose)
Capacity/Head: 50–110 m³/h / 48–72 m
Typical Application: Petrochemical sour water degassing unit, filter feed pump
Model: Sour Water Pump 65-250 OH2
Definition: API 610 OH2, DN65 outlet, 250mm impeller (medium-high pressure)
Capacity/Head: 50–110 m³/h / 75–110 m
Typical Application: Hydrotreater sour water transfer, stripper bottom outlet pump
Model: Sour Water Pump 65-315 OH2
Definition: API 610 OH2, DN65 outlet, 315mm impeller (high head)
Capacity/Head: 50–110 m³/h / 120–160 m
Typical Application: Long-distance sour water pipeline, large CCUS support sour water pump
Model: Sour Water Pump 80-160 OH2
Definition: API 610 OH2, DN80 outlet, 160mm impeller (large flow low pressure)
Capacity/Head: 80–160 m³/h / 30–48 m
Typical Application: 10+ Mt/y refinery main sour water stripping system, circulation main pump
Model: Sour Water Pump 80-200 OH2
Definition: API 610 OH2, DN80 outlet, 200mm impeller (main duty)
Capacity/Head: 80–160 m³/h / 48–72 m
Typical Application: Natural gas purification plant, sour water stripper feed pump
Model: Sour Water Pump 80-250 OH2
Definition: API 610 OH2, DN80 outlet, 250mm impeller (large flow medium-high pressure)
Capacity/Head: 80–160 m³/h / 75–115 m
Typical Application: Large petrochemical central sour water treatment system, high pressure transfer pump
Model: Sour Water Pump 80-315 OH2
Definition: API 610 OH2, DN80 outlet, 315mm impeller (large flow high pressure)
Capacity/Head: 80–160 m³/h / 120–165 m
Typical Application: High pressure sour water stripping reactor system, booster pump
Model: Sour Water Pump 100-200 OH2
Definition: API 610 OH2, DN100 outlet, 200mm impeller (large flow)
Capacity/Head: 120–220 m³/h / 45–70 m
Typical Application: Mega refining & petrochemical integrated sour water unit, circulation pump
Model: Sour Water Pump 100-250 OH2
Definition: API 610 OH2, DN100 outlet, 250mm impeller (large flow medium pressure)
Capacity/Head: 120–220 m³/h / 70–110 m
Typical Application: Offshore platform sour water transfer, long-distance pipeline pump
Model: Sour Water Pump 100-315 OH2
Definition: API 610 OH2, DN100 outlet, 315mm impeller (large flow high pressure)
Capacity/Head: 120–220 m³/h / 115–160 m
Typical Application: Large CCUS project sour water treatment unit, high pressure circulation pump
Model: Sour Water Pump 100-400 OH2
Definition: API 610 OH2, DN100 outlet, 400mm impeller (ultra-high head)
Capacity/Head: 120–220 m³/h / 180–240 m
Typical Application: Ultra-high pressure sour water stripping system, mountainous long-distance sour water transfer
Model: Sour Water Pump 125-250 OH2
Definition: API 610 OH2, DN125 outlet, 250mm impeller (very large flow)
Capacity/Head: 200–350 m³/h / 65–100 m
Typical Application: National pipeline natural gas purification plant, sour water main transfer pump
Model: Sour Water Pump 125-315 OH2
Definition: API 610 OH2, DN125 outlet, 315mm impeller (very large flow high pressure)
Capacity/Head: 200–350 m³/h / 110–155 m
Typical Application: Mega petrochemical central sour water treatment system, circulation pump
Model: Sour Water Pump 150-315 OH2
Definition: API 610 OH2, DN150 outlet, 315mm impeller (extra-large flow)
Capacity/Head: 300–550 m³/h / 90–140 m
Typical Application: Global large-scale CCUS project, sour water large-scale circulation transfer pump
Model: Sour Water Pump 150-400 OH2
Definition: API 610 OH2, DN150 outlet, 400mm impeller (top large flow high pressure)
Capacity/Head: 300–550 m³/h / 160–220 m
Typical Application: Mega refining & petrochemical integrated project, high pressure sour water regeneration system main pump
6. Contact Us