The Sulzer GSG is an API 610 (ISO 13709) Type BB5 diffuser style, multistage, radially split barrel pump. It is a cost-effective yet fully compliant solution for high pressure ammonia feed service.
Key Parameters
Flow rate: Up to 900 m³/h
Total head: Up to 2,600 m
Design pressure: Up to 300 bar (covers 15 MPa duty)
Temperature range: -30°C to +425°C (ammonia at 40°C)
Discharge sizes: 40 to 200 mm
Max speed: Up to 3,600 rpm
Design Features
Double casing (barrel type) for high pressure containment
Back-to-back impeller arrangement (opposed) for axial thrust balancing – critical for low-density liquid ammonia
Centerline mounted for uniform thermal expansion
Single or double suction first-stage impeller reduces NPSH required
Patented Twistlock closure system for quick assembly and disassembly
Materials for Ammonia Service
Standard wetted parts: 316L stainless steel
Upgrade: Duplex or super duplex for higher strength and chloride resistance
Bolting: A193 B8M (316 SS)
Gaskets / O-rings: PTFE or EPDM (FFKM for aggressive conditions)
Seal & Flush Plan
Double mechanical seal, API 682 Plan 53B (pressurized barrier fluid reservoir with bladder accumulator)
Seal faces: Silicon carbide vs. carbon (standard); tungsten carbide for severe service
Zero ammonia leakage to atmosphere
Auxiliary Systems
Heavy-duty cartridge pull-out design – maintenance without removing outer casing
Forced oil or oil ring self-lubricating bearings
Minimum flow protection (automatic recirculation valve)
Bearing temperature (RTD) and vibration monitoring (proximity probes)
Applications
High pressure ammonia feed pump for urea synthesis and green ammonia plants
Hydrocracker and ethylene shipping pumps
Boiler feed water and high-pressure water injection
Onshore and offshore crude shipping
Why Sulzer GSG for High Pressure Ammonia?
Full API 610 BB5 compliance for heavy-duty continuous service
Back-to-back rotor ensures stability on low-density liquid ammonia
Double casing provides two independent barriers against ammonia leakage
Low NPSH design with double suction first stage
API 682 Plan 53B ensures zero ammonia emissions
For more information or a custom proposal for your high pressure ammonia feed pump (Sulzer GSG) application, contact us at info@hyrig.com