HYRIG can supply VICKERS DG4V-3 and DG4V-5 directional valves. Understanding the model code is essential for selecting the correct spool type, spring arrangement, and electrical option.
| Position | Code | Meaning | Options |
|---|---|---|---|
| 1 | DG4V | Valve type | D = directional valve; G = subplate mounted; 4 = solenoid operated; V = 350 bar rated |
| 2 | -3 / -5 | Size | 3 = NG6 (CETOP 3); 5 = NG10 (CETOP 5) |
| 3 | 0C / 2A / 22 / etc. | Spool type | Determines flow paths in each position |
| 4 | A / B / F | Spring arrangement | A = spring centred; B = spring offset (end-to-end); F = spring offset (shift to centre) |
| 5 | M | Electrical option | M = solenoid with indicator light (or plain) |
| 6 | U | Electrical connection | U = ISO 4400 (DIN 43650) connector |
| 7 | H7 / G7 / B7 / D7 | Voltage code | H = 24V DC; G = 12V DC; B = 110V AC; D = 220V AC |
| 8 | 60 / 20 | Design series | 60 = DG4V-3 series; 20 = DG4V-5 series |
The spool type code determines the flow paths in each valve position. Common types include:
Need help decoding your existing nameplate or selecting a replacement? For full specifications, view the VICKERS DG4V-3 Directional Valve Series and VICKERS DG4V-5 Directional Valve Series pages. Contact HYRIG with your full model code or a photo of the nameplate, and our engineers will confirm the correct configuration.
Browse the complete VICKERS DG4V range at VICKERS DG4V Directional Valves, or decode SystemStak valve codes with the VICKERS SystemStak Flow Control Valves guide.
Disclaimer: VICKERS is a registered trademark of Eaton Corporation / Danfoss. HYRIG is an independent supplier of hydraulic components and is not affiliated with Eaton or Danfoss.
For help with VICKERS DG4V model codes, contact HYRIG: info@hyrig.com