VICKERS XG2V & XCG2V Pressure Reducing Valve Series
Overview:
HYRIG can supply the VICKERS XG2V and XCG2V series and related hydraulic components. The XG2V is a subplate-mounted pressure reducing valve. The XCG2V adds an integral check valve for free reverse flow (A to B).
VICKERS assigns unique 02-xxxxxx material numbers for complete assemblies.
| Model Code | 02- Part Number | Description |
|---|---|---|
| XCG2V-10GW-B-10 | 02-412642 | NG10, XCG type with check valve, 5–315 bar |
| XCG2V-10FW-B-10 | 02-412646 | NG10, XCG type, FW pressure range |
When replacing a VICKERS subplate reducing valve, confirm whether the original had a reverse-flow check valve (XCG2V) or not (XG2V). The XCG2V allows flow from A to B without passing through the reducing spool, which is critical for circuits with cylinders that must retract freely.
Do you need reverse flow capability? Not sure if your system requires the XG2V or XCG2V? Send us your hydraulic schematic or describe the actuator behavior, and HYRIG will advise on the correct valve type.
Used in hydraulic systems where reduced pressure is required in a subplate-mounted valve, with or without reverse free flow.
Disclaimer: VICKERS is a registered trademark of Eaton Corporation. HYRIG is an independent supplier of hydraulic components and is not affiliated with Eaton Corporation.
Specifications:
Contact Us:
For XG2V/XCG2V selection and 02- part number confirmation, contact HYRIG: info@hyrig.com