| Model | Nominal Size | Max Pressure | Max Flow | Reset Type | Solenoid Type |
|---|---|---|---|---|---|
| WE5 No-Spring | DN6 | 31.5 MPa | 60 L/min | No Spring / Detent | Standard Wet |
| WE5 Standard Valve | DN6 | 31.5 MPa | 60 L/min | Spring Return | Standard Wet |
| WE6 High Flow Valve | DN6 | 35 MPa | 80 L/min | Spring Return | High Power |
Data source: Technical data table.
Text-based mounting parameters for the WE5 no-spring valve:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-03 (CETOP 3) |
| Bolt Pattern | 4 x M5 threaded holes (40.5 x 40.5 mm) |
| Port Connections | A, B, P, T (Requires O-ring 7 x 1.5 mm) |
| Overall Length | 220 mm (Double solenoid) |
| Body Width | 45 mm |
Unlike standard spring-return valves, the O type has no spring and no detent. The spool is shifted by momentary solenoid pulses and stays in position due to fluid forces, requiring continuous power to maintain position. The OF type features a detent mechanism that mechanically holds the spool in the switched position, eliminating the need for continuous power.
Electrical Options: DC 24V, AC 220V/50Hz standard. Plug options: Z4, Z5, Z5L.
Replacing an old pulse valve? Check:
Used in hydraulic systems requiring memory functions or pulse control, such as clamping circuits, safety interlocks, and automation systems.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Not sure if you need the O or OF type? Contact our engineers with your system requirements.
Q: What is the difference between O and OF type?
A: O type has no spring and no detent. OF type has a detent to hold the spool position without continuous power.
Q: Does the OF type require continuous power?
A: No. The detent mechanism locks the spool in place, so power is only needed during switching.
Q: What is the typical lead time for the WE5 pulse valve?
A: Standard lead time is 15-20 days. Urgent requests can be accommodated if parts are in stock.
Q: Can I buy the detent kit separately?
A: Yes, we provide replacement detent mechanisms and seal kits.
For WE5 no-spring solenoid valve selection and spare parts, contact HYRIG: info@hyrig.com