HYRIG can supply the WMM10 manual directional valve range and its spare parts. The WMM10 is a direct-operated spool valve with a DN10 nominal size, operated by a hand lever for directional control. It handles up to 31.5 MPa and 100 L/min.
Conatct For Details
DetailReview(0)Additional

Key Facts

  • Nominal Size: DN10
  • Max Working Pressure: 31.5 MPa
  • Max Flow Rate: 100 L/min
  • Control Type: Manual lever (spring return or detent)
  • Mounting Standard: ISO 4401-05 (Plate connection)
  • Plug-in Damper Options: B08, B10, B12
  • Weight: Approx. 3.3 kg

WMM10 Specifications & Model Comparison

ModelNominal SizeMax PressureMax FlowMounting Standard
WMM10DN1031.5 MPa100 L/minISO 4401-05
WMM6 Manual ValveDN631.5 MPa60 L/minISO 4401-03
WMM16 Manual ValveDN1635 MPa300 L/minISO 4401-07

Data source: Technical data table.

Dimensions

Text-based mounting parameters for the WMM10 plate connection:

ParameterSpecification
Mounting InterfaceISO 4401-05 (CETOP 5)
Bolt Pattern4 x M6 threaded holes (54 x 54 mm)
Port ConnectionsA, B, P, T (Requires O-ring 12 x 2 mm)
Overall Length163 mm (excluding lever)
Body Width70 mm
Lever Angle± 24.5° from center position

Structure / Working Principle

The WMM10 uses a hand lever to mechanically shift the spool, changing the flow direction in the hydraulic circuit. When the handle is released, the spring returns the spool to the center. The /F variant features a detent to hold the position.

Available Spool Types (How to Order)

Available in multiple configurations: A, B, C, D, E, G, H, J, L, M, P, Q, R, T, U, V, W, Y.

  • Type C: Closed center.
  • Type E: Tandem center (P blocked, A & B to T).
  • Type G: Float center (all ports connected).

Damper Options: Specify `B08`, `B10`, or `B12` if your flow exceeds the rated limit.

Cross-Reference & Replacement

Replacing an old manual valve? Check:

  1. Mounting Surface: Verify the ISO 4401-05 (54 x 54 mm) bolt pattern.
  2. Spool Function: Match the center condition to your circuit.
  3. Threads: Ensure your subplate uses G1/2" or M22x1.5.

Applications

Used in construction machinery, mining equipment, and hydraulic power packs for directional control of cylinders and motors.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Selection Support

Not sure about the exact spool type or need the detent (F) version? Contact our engineers with your system requirements.

Frequently Asked Questions

Q: What is the typical lead time for the WMM10 valve?
A: The standard lead time is 15-20 days, but we support urgent requests if parts are in stock.

Q: How do I order a detent version?
A: Add the "F" suffix to your model code (e.g., WMM10-F) to specify the detent mechanism.

Q: What is the max flow rate for the WMM10?
A: The WMM10 supports a maximum flow rate of 100 L/min.

Q: Can I buy the lever assembly or seal kits separately?
A: Yes, we provide drop-in replacement maintenance kits, including O-rings and lever assemblies.

Contact