| Model | Nominal Size | Max Pressure | Max Flow | Mounting Standard |
|---|---|---|---|---|
| WMM25 | DN25 | 35 MPa | 450 L/min | ISO 4401-08 |
| WMM16 Manual Valve | DN16 | 35 MPa | 300 L/min | ISO 4401-07 |
| WMM30 Manual Valve | DN10 | 31.5 MPa | 120 L/min | ISO 4401-05 |
Data source: Technical data table.
Text-based mounting parameters for the WMM25 plate connection:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-08 (CETOP 8) |
| Bolt Pattern | 6 x M12 threaded holes |
| Port Connections | A, B, P, T (Requires O-ring 27 x 3 mm) |
| Overall Length | 335 mm (excluding lever) |
| Body Width | 117 mm |
| Lever Angle | ± 25° from center position |
The WMM25 uses a heavy-duty hand lever to mechanically shift the spool, changing the flow direction in the hydraulic circuit. When the handle is released, the spring returns the spool to the center. The /F variant features a detent to hold the position.
Available in multiple configurations: A, B, C, D, E, G, H, J, L, M, P, Q, R, T, U, V, W, Y.
Replacing an old manual valve? Check:
Used in heavy construction machinery, mining equipment, and large hydraulic power packs for directional control of large cylinders and motors.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Not sure about the exact spool type or need the detent (F) version? Contact our engineers with your system requirements.
Q: What is the typical lead time for the WMM25 valve?
A: The standard lead time is 15-20 days, but we support urgent requests if parts are in stock.
Q: How do I order a detent version?
A: Add the "F" suffix to your model code (e.g., WMM25-F) to specify the detent mechanism.
Q: What is the max flow rate for the WMM25?
A: The WMM25 supports a maximum flow rate of 450 L/min.
Q: Does the WMM25 come with O-rings?
A: Yes, standard O-rings (27 x 3 mm) for the mounting interface are included. We also supply replacement kits.
For WMM25 manual directional valve selection and spare parts, contact HYRIG: info@hyrig.com