What oil capacity does each model use?

JB/W2.2 and JB/W3: 5.8 L; JB/W5.5: 8.6 L; JB/W7.5 and JB/W11: 16.7 L; JB/W15: 27.2 L; JB/W18.5 and JB/W22: 48.9 L.

What is the correct rotation direction?

Viewed from the motor end, the fan rotates clockwise. Viewed from above, the impeller rotates clockwise. Adjust motor wiring if the direction is wrong.

What bolt size connects the impeller?

JB/W2.2 to JB/W7.5: M12×55, 8 pcs; JB/W11: M16×60, 8 pcs; JB/W15: M16×80, 8 pcs; JB/W18.5 and JB/W22: M16×80, 10 pcs.

Is 60Hz / 460V available?

Yes. Motors can be supplied in 50Hz/380V or 60Hz/460V configurations, with corresponding impeller speeds and displacement.

What safety precautions apply during installation?

Hoist the agitator horizontally and fix ropes firmly. Fill the reducer with specified oil before operation. Disconnect motor power during impeller installation. Do not energize the motor while personnel are inside the tank.