Our API 610 1# extract column bottom pumps are available in BB2, OH, and VS designs, specifically engineered for transferring high‑temperature mixed aromatic bottoms – approximately 51% xylenes, 49% toluene, and 0.02% ethylbenzene – from 1# extract columns to downstream processing in aromatics complexes. BB2 pumps with radially split between‑bearings construction are the preferred choice for reliable high‑temperature bottom duty, delivering stable flow with excellent rotor rigidity and thermal expansion management. OH pumps serve smaller applications, while VS pumps handle low‑NPSH suction. Built with chrome‑moly, stainless, and fouling‑resistant alloys. Fully API 610/ISO 13709 compliant for long‑life, reliable service.

Conatct For Details
DetailReview(0)Additional

Our API 610 1# extract column bottom pumps are heavy‑duty centrifugal pumps engineered specifically for transferring high‑temperature mixed aromatic bottoms from 1# extract columns to storage or downstream processing in aromatics complexes and petrochemical plants. The 1# extract column is a critical unit in aromatics production that separates high‑value aromatic components. The bottom product is a mixed aromatic stream with a typical composition of approximately 51.22% xylenes (including para‑xylene, ortho‑xylene, meta‑xylene), 48.61% toluene, and 0.02% ethylbenzene, with negligible benzene. This mixed aromatic bottoms stream serves as a valuable feedstock for para‑xylene (PX) extraction units, toluene disproportionation, and various petrochemical applications.

The bottom stream is characterized by elevated temperatures (typically 170‑220°C), moderate viscosity, fouling tendencies, and often contains trace sulfur compounds. Pumps for this service demand robust construction, reliable sealing, stable flow control, and excellent thermal management. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for continuous, reliable, and safe operation. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – with the BB2 type (radially split, single‑stage or two‑stage) being the preferred choice for main bottom product transfer duties due to its superior rotor stability and thermal expansion management.

API 610 Classifications for 1# Extract Column Bottom Duties

  • BB2 – Between Bearings Pumps (Preferred for Main Bottom Product Transfer)
    For the main mixed aromatic bottoms transfer from the 1# extract column, the BB2 subtype (radially split, single‑stage or two‑stage, between‑bearings) is the preferred configuration. The radially split casing allows the pump to expand evenly with temperature without distorting internal clearances – critical when handling streams with significant temperature differentials. The between‑bearings arrangement provides exceptional rotor rigidity, minimising shaft deflection and vibration. Single‑stage BB2 pumps handle moderate to high flows (50‑1,500 m³/h) at heads up to 200 metres, while two‑stage variants cover higher head requirements. Centreline support accommodates thermal expansion.

  • OH – Overhung Pumps
    In 1# extract column systems, OH pumps are typically employed for smaller transfer duties, booster services, or auxiliary applications where flows are lower. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes provide compact, cost‑effective solutions for auxiliary roles. Centreline mounting ensures thermal expansion does not misalign the pump and driver.

  • VS – Vertically Suspended Pumps
    VS pumps are used where the column bottom has very low NPSH or where floor space is limited. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the first‑stage impeller below the liquid level, providing excellent NPSH performance. They are also used in closed‑loop systems where floor space is limited.

Key Performance & Design Features (BB2 Focus)

  • Temperature Capability – Engineered for mixed aromatic temperatures up to 220°C (428°F), with appropriate material selection and thermal expansion allowances.

  • Flow & Head – Capacities from 20 m³/h to over 1,500 m³/h; heads typically from 50 to 200 metres.

  • Casing Design – Radially split casing with centreline support to accommodate thermal expansion without distortion. Heavy‑wall construction for pressure integrity at elevated temperatures.

  • Materials – Wetted parts in chrome‑moly steels (ASTM A217 WC6/WC9), 12% chrome stainless steels, duplex stainless, or high‑alloy materials for corrosion resistance to trace sulfur compounds and aromatic degradation products. Full hard facing on wear rings and impeller shrouds to resist fouling and erosion.

  • Fouling Resistance – Impeller and casing designs that minimise stagnant areas and heavy component deposition; optional steam tracing or jacketing to maintain fluidity and prevent fouling/polymerisation.

  • Sealing – API 682 mechanical seals (single, dual, or tandem) with high‑temperature flush plans – typically Plan 32 (clean injected flush), Plan 62 (steam quench), or Plan 53 (pressurised dual seal) – to prevent heavy component build‑up and ensure seal face stability. Steam quench is strongly recommended for aromatic services to flush away any leakage and prevent fouling.

  • Bearing & Lubrication – Heavy‑duty sleeve or tilting‑pad journal bearings and Kingsbury‑type thrust bearings with forced oil lubrication; bearing temperature and vibration monitoring for predictive maintenance.

  • Impeller Options – Closed impellers with large clearances to handle thermal expansion and minor fouling; open or semi‑open designs for severe fouling services; all dynamically balanced per API 610.

  • Thermal Expansion – Adequate internal clearances, expansion joints, and flexible coupling designs to accommodate significant temperature gradients.

Typical Applications

  • Mixed aromatic bottoms transfer from 1# extract columns

  • Xylene/toluene rich product transfer to para‑xylene (PX) extraction units

  • 1# extract column bottom pumping in aromatics complexes

  • Mixed aromatic supply to storage or downstream fractionation units

  • Any extract column handling mixed aromatic bottom streams

Industries Served

  • Petrochemicals (aromatics production, xylene/toluene processing)

  • Oil refineries (aromatics complexes)

  • Chemical processing (aromatic separation and upgrading)

Why Choose Our 1# Extract Column Bottom Pumps?

With deep expertise in high‑temperature aromatic handling and full API 610 compliance, we design and manufacture 1# extract column bottom pumps that deliver unmatched reliability, safety, and efficiency. Every pump undergoes rigorous hydrostatic testing, performance curve verification, mechanical running tests, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet the most stringent owner‑operator specifications. We offer customised hydraulic designs, material upgrades, fouling‑resistant impeller designs, and sealing arrangements tailored to your specific mixed aromatic composition, temperature, and fouling characteristics. Our engineering support includes API 684 rotor dynamics, thermal expansion analysis, and NPSH margin studies to ensure seamless, long‑term operation in the most demanding extract column services.

Contact Us

For technical datasheets, application engineering advice, or a project‑specific quotation, please contact us at:

info@hyrig.com

Trust our API 610 1# extract column bottom pumps to deliver reliable mixed aromatic product transfer for your aromatics production processes.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit