Correct installation of the 110103-502 Upper IBOP on a VARCO TDS-11SA top drive in sour gas service requires additional precautions due to H₂S exposure.
Inspect the IBOP – Check for NACE compliance markings, clean all surfaces.
Verify threads – Confirm top connection (4-1/2" IF female) matches TDS-11SA spindle.
Check HNBR seals – Ensure no cracks or hardening.
Prepare thread compound – Use NACE-approved thread lubricant (must be sulfur-free, suitable for H₂S service). Standard API 7-1 compound may not be acceptable for sour service.
| Step | Action |
|---|---|
| 1 | Apply NACE-approved thread compound to both the IBOP top threads and TDS-11SA spindle threads. |
| 2 | Hand-thread the IBOP onto the spindle until finger tight. |
| 3 | Use a torque wrench to tighten to 13,500 – 15,000 N·m (10,000 – 11,000 ft·lbs). |
| 4 | Attach the T-handle and verify smooth operation. |
| 5 | Connect the bottom string (use NACE-approved compound on those threads as well). |
Per API 16D, perform tests before drilling. Use non-acidic test fluid (fresh water or inhibited brine). Do not use H₂S-containing fluid for testing.
Low-pressure test: Close IBOP, apply 500 psi from below. Hold 5 minutes. No visible leakage.
High-pressure test: Apply 5,000 psi from below. Hold 5 minutes. No pressure drop.
Shell test: Open IBOP, apply 7,500 psi to body. No leakage.
| Interval | Action |
|---|---|
| Daily / each tour | Cycle valve. Check for smooth operation. Document any stiffness. |
| Weekly | Visual inspection for pitting, corrosion, or seal swelling. |
| Per API 16D (14 days) | Pressure test (low and high). Record results. |
| After 300 cycles or 6 months | Replace HNBR seals. Inspect ball and seats for H₂S damage. |
| After any H₂S exposure event | Inspect for sulfide stress cracking (non-destructive testing recommended). |
The 110103-502 uses an HNBR seal kit for H₂S resistance. Do not substitute NBR seals.
Replacement procedure:
Remove IBOP from top drive.
Purge with inert gas (if H₂S has been present) before disassembly.
Unscrew end pieces (use proper tools).
Extract ball, seats, and seals.
Clean all components with approved solvent (non-chlorinated).
Inspect for cracking or pitting – if found, replace ball or body.
Install new HNBR seals (lubricate with H₂S-compatible grease).
Reassemble and torque end pieces to specification.
Pressure test before returning to service.
Repair kit part number: Contact info@hyrig.com for HNBR repair kit.
| Problem | Possible Cause | Solution |
|---|---|---|
| Hard to turn | HNBR seal swelling (incompatible fluid) | Replace seals with correct material |
| Hard to turn | H₂S corrosion on ball | Inspect, replace ball if pitted |
| Leaks when closed | Seal degradation from H₂S | Replace HNBR seals |
| Thread galling | Wrong thread compound | Use NACE-approved compound |
| Cracking on body | SSC (sulfide stress cracking) | Remove from service, replace |
Always use H₂S monitoring when handling IBOP that has been in sour service.
Decontaminate before disassembly (soak in neutralizing solution if required).
Use non-sparking tools in H₂S areas.
Never reuse seals after H₂S exposure – replace with new HNBR kit.
For HNBR repair kits, NACE documentation, or field assistance:
Email: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.