110103-502 Upper IBOP – Sour Service Installation & Maintenance Guide

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Installation and maintenance instructions for 110103-502 sour service upper IBOP on VARCO TDS-11SA. Use NACE-approved thread compound, HNBR seal care, pressure testing per API 16D. Special procedures for H₂S environments.

Conatct For Details
DetailReview(0)Additional

Proper Installation for H₂S Environments

Correct installation of the 110103-502 Upper IBOP on a VARCO TDS-11SA top drive in sour gas service requires additional precautions due to H₂S exposure.

Before Installation

  1. Inspect the IBOP – Check for NACE compliance markings, clean all surfaces.

  2. Verify threads – Confirm top connection (4-1/2" IF female) matches TDS-11SA spindle.

  3. Check HNBR seals – Ensure no cracks or hardening.

  4. Prepare thread compound – Use NACE-approved thread lubricant (must be sulfur-free, suitable for H₂S service). Standard API 7-1 compound may not be acceptable for sour service.

Installation Steps

StepAction
1Apply NACE-approved thread compound to both the IBOP top threads and TDS-11SA spindle threads.
2Hand-thread the IBOP onto the spindle until finger tight.
3Use a torque wrench to tighten to 13,500 – 15,000 N·m (10,000 – 11,000 ft·lbs).
4Attach the T-handle and verify smooth operation.
5Connect the bottom string (use NACE-approved compound on those threads as well).

Pressure Testing After Installation (Sour Service)

Per API 16D, perform tests before drilling. Use non-acidic test fluid (fresh water or inhibited brine). Do not use H₂S-containing fluid for testing.

  1. Low-pressure test: Close IBOP, apply 500 psi from below. Hold 5 minutes. No visible leakage.

  2. High-pressure test: Apply 5,000 psi from below. Hold 5 minutes. No pressure drop.

  3. Shell test: Open IBOP, apply 7,500 psi to body. No leakage.

Maintenance Schedule for Sour Service

IntervalAction
Daily / each tourCycle valve. Check for smooth operation. Document any stiffness.
WeeklyVisual inspection for pitting, corrosion, or seal swelling.
Per API 16D (14 days)Pressure test (low and high). Record results.
After 300 cycles or 6 monthsReplace HNBR seals. Inspect ball and seats for H₂S damage.
After any H₂S exposure eventInspect for sulfide stress cracking (non-destructive testing recommended).

Seal Replacement (HNBR Repair Kit)

The 110103-502 uses an HNBR seal kit for H₂S resistance. Do not substitute NBR seals.

Replacement procedure:

  1. Remove IBOP from top drive.

  2. Purge with inert gas (if H₂S has been present) before disassembly.

  3. Unscrew end pieces (use proper tools).

  4. Extract ball, seats, and seals.

  5. Clean all components with approved solvent (non-chlorinated).

  6. Inspect for cracking or pitting – if found, replace ball or body.

  7. Install new HNBR seals (lubricate with H₂S-compatible grease).

  8. Reassemble and torque end pieces to specification.

  9. Pressure test before returning to service.

Repair kit part number: Contact info@hyrig.com for HNBR repair kit.

Troubleshooting in Sour Service

ProblemPossible CauseSolution
Hard to turnHNBR seal swelling (incompatible fluid)Replace seals with correct material
Hard to turnH₂S corrosion on ballInspect, replace ball if pitted
Leaks when closedSeal degradation from H₂SReplace HNBR seals
Thread gallingWrong thread compoundUse NACE-approved compound
Cracking on bodySSC (sulfide stress cracking)Remove from service, replace

Safety Notes for Sour Service

  • Always use H₂S monitoring when handling IBOP that has been in sour service.

  • Decontaminate before disassembly (soak in neutralizing solution if required).

  • Use non-sparking tools in H₂S areas.

  • Never reuse seals after H₂S exposure – replace with new HNBR kit.

Contact for Sour Service Support

For HNBR repair kits, NACE documentation, or field assistance:
Email: info@hyrig.com