The 110103-502 sour service upper IBOP provides primary well control on VARCO TDS-11SA in H₂S wells. NACE MR0175 compliant. Learn kick detection, IBOP closure in acidic gas, and post-H₂S maintenance. Essential for sour gas drilling safety.

Conatct For Details
DetailReview(0)Additional

The Role of a Sour Service IBOP in H₂S Environments

On a VARCO TDS-11SA top drive drilling in sour gas wells, the 110103-502 Upper IBOP is more than a barrier – it is a critical safety device that must remain functional despite exposure to hydrogen sulfide (H₂S). Standard IBOPs (110103-500) will fail prematurely in H₂S due to sulfide stress cracking and seal degradation.

Why Use the 110103-502 in Sour Wells

FeatureBenefit
NACE MR0175 alloyResists sulfide stress cracking (SSC)
HNBR sealsWithstands H₂S without swelling or hardening
Corrosion-resistant ballMaintains smooth operation in acidic fluids

Well Control Procedures Specific to H₂S Kicks

When a kick is detected in a sour gas well, speed and safety are paramount. The driller must close the upper IBOP immediately while protecting personnel from H₂S release.

1. H₂S Kick Detection Signs

  • Increase in H₂S monitor readings at flowline or shakers

  • Pit gain with characteristic rotten egg smell (use monitors, not nose)

  • Change in mud properties (pH drop, increased viscosity)

2. Immediate Actions

StepAction
1Activate rig H₂S alarm
2Don breathing apparatus (if not already)
3Stop rotation and pump
4Close upper IBOP 110103-502
5Close lower IBOP (if installed)
6Close annular BOP
7Verify closure – pressure should stabilize
8Evacuate non-essential personnel upwind

3. After Closing the IBOP

  • Record SIDPP and SICP (shut-in pressures)

  • Do not attempt to circulate immediately – H₂S may be in the annulus

  • Consider pumping a barite pill to kill the well before circulating if H₂S concentration is high

  • If circulating is required, use H₂S scavenger in mud

Operating Sequence for Sour Gas Well Control with 110103-502

EventAction
Normal drilling (sour gas expected)IBOP open, H₂S monitors active
Kick detected (H₂S present)Stop pump → Close 110103-502 → Close BOPs
After BOPs closedEvacuate, record pressures
Determine if H₂S is in annulusMonitor casing pressure, H₂S sensors
If H₂S confirmed in annulusPump kill fluid with scavenger, do not circulate to surface
Kill wellBullhead if possible, or reverse circulate with scavenger

Post-H₂S Event IBOP Inspection

After any H₂S exposure, the 110103-502 must be:

  1. Removed and decontaminated.

  2. Inspected for sulfide stress cracking (dye penetrant or MPI).

  3. Disassembled and HNBR seals replaced (even if visually OK).

  4. Ball and seats inspected for pitting.

  5. Pressure tested before re-use.

Common Mistakes in Sour Gas Well Control

  • ❌ Using standard IBOP (110103-500) in H₂S well – risk of catastrophic failure.

  • ❌ Delaying IBOP closure to observe kick – H₂S can reach surface in minutes.

  • ❌ Opening IBOP without verifying pressure equalization – could release H₂S to rig floor.

  • ❌ Reusing seals after H₂S exposure – HNBR has limited life, replace.

Emergency Actions for H₂S Release Through IBOP

If the 110103-502 fails and H₂S escapes to the rig floor:

  1. Activate emergency shutdown.

  2. All personnel don breathing apparatus.

  3. Evacuate to safe briefing area upwind.

  4. Close BOP shear rams if necessary.

  5. Call for well control specialist.

Documentation & Training

We provide:

  • NACE MR0175 compliance certificates

  • H₂S well control worksheets

  • IBOP inspection log for sour service

Contact for Sour Gas Well Control Advisory

For training materials, H₂S-specific IBOP procedures, or spare 110103-502 units:
Email: info@hyrig.com

*Also available: Lower IBOP 114706-502 for dual sour service isolation.*