On a BPM DQ50BSC top drive, the 9703320000 Lower IBOP provides redundant isolation inside the drill string. While the upper IBOP (9703340000) is hydraulically actuated through the PLC control system and serves as the primary barrier, the lower IBOP is manually operated and serves as the secondary barrier. Dual IBOP configuration is recommended for critical wells, especially in deep or high-pressure drilling.
| Scenario | Upper IBOP (hydraulic) | Lower IBOP (manual) |
|---|---|---|
| Normal drilling | Open (PLC controlled) | Open |
| Before breaking connection | Closed (hydraulic) | Open (or closed) |
| Upper IBOP leaks when closed | Leaking | Closed – contains pressure |
| Upper IBOP fails to close | Failed open | Closed – provides isolation |
| Hydraulic system failure | Inoperable | Manual – fully functional |
| Need to service upper IBOP | Removed | Closed – allows safe removal |
The manual operation of the lower IBOP is a critical advantage during hydraulic system failure or electrical control system malfunctions. Unlike the upper IBOP which requires hydraulic pressure and PLC signals to operate, the 9703320000 can be closed or opened using a simple manual wrench under any rig condition.
Upon detecting a kick, the driller closes both upper and lower IBOPs. This ensures that even if the hydraulic upper IBOP has minor leakage or fails to seal completely, the manual lower IBOP will hold pressure.
Procedure: Stop pump → Close upper IBOP (hydraulic) → Close lower IBOP (manual) → Close BOPs.
If pressure testing shows a slow pressure drop when upper IBOP alone is closed, close the lower IBOP to confirm isolation. If pressure stabilizes, the upper IBOP requires maintenance or seal replacement.
If the DQ50BSC hydraulic system loses pressure or the PLC control system malfunctions, the upper IBOP may be inoperable. The lower IBOP remains fully functional as a manual valve and becomes the primary barrier.
The lower IBOP can be closed and pressure bled off between the two valves. This creates a trapped pressure zone, allowing the upper IBOP to be removed and serviced while the drill string remains under pressure below.
When tripping pipe out of the hole and no float valve is present, both IBOPs should be closed at all times for absolute isolation.
Drilling / circulating: Both IBOPs open
Before breaking connection: Close upper IBOP (hydraulic). Lower IBOP may remain open unless well conditions require dual closure
| Step | Action |
|---|---|
| 1 | Stop rotation and mud pump |
| 2 | Actuate upper IBOP close via driller console (PLC/hydraulic) |
| 3 | Verify upper IBOP closed via pressure monitoring |
| 4 | Manually close lower IBOP using dedicated wrench |
| 5 | Close annular BOP |
| 6 | Record shut-in pressures (SIDPP, SICP) |
Before opening the upper IBOP when there is pressure trapped below:
Close upper IBOP.
Close lower IBOP (trap pressure between them).
Open a small bleed valve or slowly crack the connection above the lower IBOP.
Once pressure equalizes, open upper IBOP.
Note: The 9703320000 does not have a built-in equalization port. Equalization is accomplished via a separate bleed valve or by gradually loosening the connection above.
| Step | Action |
|---|---|
| 1 | Close lower IBOP (9703320000) manually |
| 2 | Bleed pressure from the space between upper and lower IBOP via top drive washpipe or bleed valve |
| 3 | Verify zero pressure in the space |
| 4 | Remove upper IBOP for service |
| 5 | Lower IBOP holds well pressure below |
This procedure is critical for maintaining well control while servicing the upper IBOP.
The 9703320000 is a manually operated ball valve. Operation instructions:
Close: Rotate clockwise using the dedicated wrench until fully closed
Open: Rotate counter-clockwise using the dedicated wrench until fully open
Always cycle fully open or fully closed – never leave partially open under pressure
The valve requires a specialized tool provided in the BPM tool kit (Part number: 9709320301, six-point socket wrench)
If the hydraulic upper IBOP fails (cannot close, leaks severely, or hydraulic system is inoperable), the manual lower IBOP becomes the primary barrier. In this mode:
Do not open lower IBOP unless absolutely necessary
Plan to replace or repair upper IBOP at the next connection or trip
If both IBOPs fail, rely on BOP stack and consider stripping procedures
| Barrier | Purpose | Operation |
|---|---|---|
| Upper IBOP (9703340000) | Primary internal barrier | Hydraulic / PLC controlled |
| Lower IBOP (9703320000) | Secondary internal backup | Manual wrench |
| Annular BOP | Seals around drill pipe in annulus | Hydraulic |
| Ram BOPs (pipe & shear) | Seal around pipe or cut and seal | Hydraulic |
Test both IBOPs separately – test lower IBOP with upper IBOP open, then test both closed
Cycle the lower IBOP manually every day – manual valves can seize if left static for long periods
Mark positions clearly – the manual valve should have open/closed indicator
Train drill crews on manual IBOP operation – the manual valve is often overlooked in well control drills
Keep the dedicated manual wrench at the driller station at all times
Log all pressure tests and maintenance activities for both IBOPs
Upper IBOP is still available as primary barrier (if hydraulic system functional)
Strip back to BOPs and close annular and pipe rams
Replace lower IBOP at the next trip
Immediately close annular BOP
Close pipe rams if possible
Consider shear rams if well continues to flow
Pump barite plug or set bridge plug
A standard heavy-duty ratchet with appropriate socket may be used temporarily
Immediately source the correct tool (9709320301) for proper torque application
Using lower IBOP as the primary barrier for routine connections – use upper IBOP first
Opening lower IBOP before verifying no pressure below – can cause well flow to surface
Forgetting to close lower IBOP before removing upper IBOP for service
Using incorrect wrench – may damage valve stem or fail to achieve full closure
Operating the valve too slowly during a kick – manual valves take time; practice speed
Neglecting low-pressure test on manual valve – small leaks may go undetected
We provide:
Dual IBOP well control worksheets for BPM DQ50BSC
Quick-reference cards for driller console
API test report templates
Manual operation procedure cards
For training materials, emergency support, or spare lower IBOPs: info@hyrig.com
Also available: Upper IBOP 9703340000 to complete dual barrier isolation, and complete BPM DQ50BSC top drive spare parts inventory.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.