DL series canned vertical multistage centrifugal pump designed and manufactured in full accordance with API 610 11th Edition Type VS6 standard. It adopts a double‑casing construction comprising a segmental outer barrel and a diffuser‑type inner hydraulic section, offering high head and extremely low NPSH characteristics. The pump is primarily used for continuous or intermittent lifting of condensate from surface or underground hot wells in thermal, combined‑cycle and nuclear power plants, as well as for LP heater drain pumping and return water boosting. Its inherent flooded‑suction arrangement effectively solves suction lift and priming problems, making it ideal for NPSH‑critical and space‑limited installations. API 682 seal support systems are available.

Conatct For Details
DetailReview(0)Additional

The DL series is a high‑efficiency centrifugal pump that fully complies with API 610 11th Edition (ISO 13709). It is classified as Type VS6: a vertically suspended, multi‑stage, radially split double‑casing pump (often referred to as a “barrel” or “canned” pump)-1. The pump incorporates an outer barrel that forms the pressure‑containing shell and an inner diffuser‑type element that houses the multistage impeller stack; dual casing construction enables reliable safe containment even when the hot well liquid carries non‑condensable gases, slight solids or is near its saturation point.

Key Parameters

ParameterRange (representative)
Flow rate QUp to ~800 m³/h (customizable up to 1,000 m³/h)
Total head HUp to ~1,200 m (customizable up to 1,500 m)
Maximum speedUp to 3,600 rpm
Design pressureUp to 20.0 MPa (higher on request)
Operating temperature-200°C to +250°C
Flange ratingASME Class 150 / 300 / 600 (matched to system pressure)

Design Features

FeatureBenefit
Double‑casing (barrel) constructionOuter barrel and inner diffuser‑type hydraulic section contain high system pressure, eliminate catastrophic leakage, and provide superior vibration damping even in deep sump installation.
Multistage, radially split diffuser designMultiple impellers arranged in series generate high total dynamic head efficiently; radial diffuser vanes convert velocity energy to pressure without radial thrust imbalance.
Low NPSH first‑stage impeller or inducerFirst stage uses an anti‑cavitation impeller or integral inducer, dramatically lowering NPSHR and preventing cavitation damage even when pumping condensate near the saturation point.
Down‑thrust balancing (balance drum)A hydraulic balance drum/disc counteracts the down‑thrust created by multistage impellers; the rotor remains axially stable under varying load, avoiding repeated thrust‑bearing contact.
Water‑lubricated line‑shaft guide bearings or product‑lubricatedClean condensate or the working liquid itself lubricates the submerged guide bearings; no external oil supply in the lower part eliminates auxiliary oil leaks.
Submerged bearing spacer complies with API 610 spacing limitsGuide bearing spans are designed to maintain first critical speed above the pump running speed, ensuring continuous trouble‑free operation.
Top‑mounted thrust bearing (oil lubricated)Takes the residual down‑thrust after the balance device; designed for long‑life operation in continuous condensate extraction duty.
API 682 seal chamber (above grade)Mechanical seal located in the discharge head is completely above the floor; packaged Plan 11, Plan 53B or Plan 62 seal support systems are available.
Flanged column sectionsThe barrel and column are built up from flanged sections, allowing easy disassembly for internal inspection without removing motor or foundations.
Reverse‑rotation prevention device (optional)Prevents the pump from spinning backwards when the driver stops; protects shaft joints and the first‑stage impeller.

Mechanical Seal & API 682 Flush Plans

The discharge head is fitted with an API 682 seal chamber. Recommended configurations for electric motor drives:

ServiceRecommended SealFlush Plan
Clean condensate <120°C, low hazardSingle cartridge mechanical sealPlan 11
Warm condensate >120°C towards saturationSingle seal with coolerPlan 21 or Plan 23
Toxic or fugitive‑emission serviceTandem (non‑pressurized) sealPlan 52
Closed reactor feed or high‑risk dutyDouble pressurized sealPlan 53B

Materials of Construction

ComponentStandard MaterialOption
Outer barrel (筒体段)Carbon steel (Q235B / WCB)304SS / 316LSS
Inner casing (导流壳体/内壳体)304SS / 316LSS (cast)Duplex 2205 / super duplex
Impellers (叶轮)304SS / 316LSSDuplex / high‑chromium white iron
Shaft (主轴)17-4PH stainless steelDuplex / Inconel 718
Wear rings / bushingsHardened 12% Cr + Stellite facingSilicon carbide / tungsten carbide
Balance drum / sleeve13Cr steel + Stellite facingCarbide‑overlay sleeve + replaceable bushing
Gaskets / O‑ringsPTFE / spiral wound (SS+graphite) / EPDMFFKM / Viton

Auxiliary & Monitoring Systems

  • Minimum flow recirculation – An automatic recirculation valve (ARC) or a control valve + orifice plate is required to maintain the pump above its minimum continuous stable flow (MCSF) when the main discharge valve is closed.

  • Submerged bearing flush – Clean condensate is routed to guide bearing chambers; an optional external flushing connection (e.g., using demineralized water) can be specified if the pumped condensate contains soft debris.

  • Venting – High‑point vents in the discharge head and barrel allow startup air removal and prevent vapour locking.

  • Drains – Double‑isolated low‑point drain connections facilitate safe flushing and maintenance.

  • Bearing temperature monitoring (above grade) – RTD (PT100) sensors are provided in the upper housing containing the oil‑lubricated thrust bearing and in the upper radial bearing.

  • Shaft vibration monitoring – Proximity probes (eddy current) or accelerometers are fitted to the discharge head per API 670 for high‑energy units.

  • Process instrumentation – Suction and discharge pressure transmitters (chemical‑seal type if fluid is corrosive), and temperature transmitters on the can/suction and discharge nozzles.

Applications

The DL series (API 610 Type VS6) is well suited for:

  • Power plants (coal‑fired, gas‑fired CCPP, nuclear) – Condenser hot‑well extraction, low‑pressure heater drain pumping, and condensate polishing unit transfer.

  • Industrial process steam & CHP plants – Return condensate lifting from flash tanks, heat network boosters, and steam trap transfer systems.

  • Geothermal power stations – Lifting geothermal brine or flash condensate from low‑head separators and sumps.

  • Petrochemical & refining – Condensate extraction in tower overhead systems and tank‑farm hot well drainage.

  • LNG / cryogenic facilities – Pumping low‑temperature (cryogenic) liquids, with appropriate low‑temperature steel or 9% Ni steel materials.

Typical China manufacturer references for API 610 VS6 pumps

  • JHDL series (昆明嘉和科技) – Vertical canned multistage barrel pump: flow ~800 m³/h, head ~1,000 m, pressure to 10 MPa, temperature -55 to +180°C-23. API 610 11th compliant; typical services: condensate extraction, coal chemical, LNG.

  • VDD series (江苏双达泵业) – API 610 Type VS6: flow 20~1,000 m³/h, head ~1,000 m, design pressure 15.0 MPa, temperature -102 to +250°C-24. Typical use: condensate extraction, pipeline pressure regulation, cryogenic applications.

  • ASP5560 series (三联泵业) – VS6 barrel pump: flow up to 1,500 m³/h, pressure up to 10 MPa, temperature -80 to +250°C-47. Radial split, multi‑stage, API 610 10th Ed.

  • CP-VS1/VS6 series (长志能源) – VS1/VS6 vertical suspended pump: flow 5~840 m³/h, head 20~900 m, pressure up to 11 MPa, temperature -196 to +150°C-26. API 610 11th Ed; low‑temperature and low‑NPSH applications.

  • TTMC series (Sulzer technology) – Rigid‑shaft barrel design with balancing drum; temperature ≥ -50°C-. Typically used for hydrocarbon process services.

Why Choose DL Series (VS6) for Condensate Extraction?

  • Fully compliant with API 610 Type VS6 and ISO 13709

  • Low NPSHR: excellent anti‑cavitation capability

  • Reliable flooded‑suction design: no priming, covers fluctuating hot‑well level

  • Double casing eliminates leak‑through risks

  • High head and flow capacity

  • Modular, standardised design reduces number of hydrodynamic stages

  • Wide material selection for corrosive and high‑temperature service

For more information on selecting the correct DL series VS6 condensate extraction pump, please send your enquiry to info@hyrig.com.