The DL series is a high‑efficiency, heavy‑duty vertical multistage turbine pump designed entirely in accordance with API 610 11th Edition (ISO 13709) and classified as Type VS6: a vertically suspended, multistage, radially split double‑casing (barrel) pump.
The pump consists of an outer barrel that forms the pressure‑containing shell and an inner diffuser‑type element housing the multistage impeller stack. This double‑casing construction provides safe containment even when pumping fluids containing non‑condensable gases or trace solids. The flooded suction arrangement eliminates priming problems and offers excellent cavitation resistance – making the DL series particularly suited for deep‑well, low‑NPSH applications.
Key Parameters
| Parameter | Range |
|---|---|
| Flow rate Q | 20 – 1,000 m³/h (customizable up to 5,500 m³/h) |
| Total head H | Up to 1,000 m (customizable up to 1,500 m) |
| Design pressure | Up to 15.0 MPa (150 bar) |
| Operating temperature | -102°C to +250°C |
| Max speed | Up to 3,600 rpm |
| Flange rating | ASME Class 150 / 300 / 600 |
Design Features
| Feature | Benefit |
|---|---|
| Double‑casing (barrel) construction | Outer barrel and inner diffuser‑type hydraulic section contain high system pressure, eliminating catastrophic leakage, providing superior vibration damping. |
| Multistage radial diffuser design | Multiple impellers in series generate high total dynamic head efficiently; radial diffuser vanes convert velocity energy to pressure without radial thrust imbalance. |
| Balance drum axial thrust balancing | Hydraulic balance drum counteracts down‑thrust created by multistage impellers; rotor remains axially stable under varying load, avoiding repeated thrust bearing contact. |
| Low NPSH first‑stage impeller / inducer | First‑stage impeller equipped with anti‑cavitation design or integral inducer dramatically lowers NPSHR, preventing cavitation when pumping from deep wells with limited submergence. |
| Multi‑point sliding bearings | API 610‑compliant bearing spacing ensures safe operation; bearings use high‑wear‑resistant graphite or composite materials. |
| API 682 seal chamber | Mechanical seal located in discharge head is completely above grade; packaged Plan 11, Plan 53B or Plan 62 seal support systems available. |
| Thermowell & vibration monitoring ports | Standard provisions for RTD and accelerometer installation enabling real‑time health monitoring. |
| Flanged column sections | Column and barrel built up from flanged sections, allowing easy disassembly for inspection without removing motor or foundations. |
Materials of Construction
| Component | Standard Material | Options |
|---|---|---|
| Outer barrel | Carbon steel (WCB / Q235B) | 304SS / 316LSS |
| Inner casing / diffusers | 304SS / 316LSS (cast) | Duplex 2205 / super duplex |
| Impellers | 304SS / 316LSS | Duplex / high‑chromium white iron / bronze |
| Shaft | 17-4PH stainless steel | Duplex / Inconel 718 |
| Wear rings / bushings | Hardened 12% Cr + Stellite facing | Silicon carbide / tungsten carbide |
| Balance drum / sleeve | 13Cr steel + Stellite facing | Carbide‑overlay sleeve |
| Gaskets / O‑rings | PTFE / spiral wound (SS+graphite) | FFKM / Viton |
Mechanical Seal & API 682 Flush Plans
Seal chamber in the discharge head accepts cartridge mechanical seals per API 682. Recommended configurations:
| Service | Recommended Seal | Flush Plan |
|---|---|---|
| Clean water (<80°C), low hazard | Single cartridge mechanical seal | Plan 11 |
| Warm water (80‑120°C) | Single seal with cooler | Plan 21 or Plan 23 |
| Toxic or fugitive‑emission service (e.g., hydrocarbon wells) | Tandem (non‑pressurized) seal | Plan 52 |
| High‑risk / corrosive service | Double pressurized seal | Plan 53B |
Auxiliary & Monitoring Systems
| System | Requirement |
|---|---|
| Minimum flow protection | Automatic recirculation valve (ARC) or control valve + orifice – prevents overheating at low load. |
| Bearing cooling | Water‑cooled housings for fluid >120°C; air cooling for moderate temperatures. |
| Casing drains / vents | Double‑isolated low‑point drains and high‑point vents for safe purging and maintenance. |
| Bearing temperature RTD | PT100 sensors in upper housing; 4‑20 mA to DCS; alarm at 85°C, trip at 95°C. |
| Shaft vibration monitoring | Proximity probes (eddy current) or accelerometers per API 670 for high‑energy units. |
| Process instrumentation | Suction / discharge pressure transmitters (chemical‑seal type for corrosive fluids), temperature transmitters. |
Applications
Industrial and municipal deep‑well water supply – Lifting groundwater from deep boreholes.
Irrigation and agricultural water supply – High‑lift pumping from wells or reservoirs.
Mine dewatering – Underground mine drainage and pit dewatering.
Power plants – Cooling water circulation; auxiliary service water from deep wells.
Petrochemical refineries – Crude oil pipeline transport; water injection for EOR.
Geothermal reinjection – Pumping separated brine back into reservoirs.
Sea water lift – Cooling intake from deep submerged inlets (with duplex materials).
Pipeline pressure regulation – Boosting pressure in water transmission mains.
LNG / cryogenic facilities – Handling light hydrocarbons (propane, pentane) at low temperatures.
China Manufacturer References
The DL series (API 610 Type VS6) is widely supplied by leading Chinese pump manufacturers:
Shandong Changzhi Energy Equipment – HP‑VS1/VS6 series: flow 5‑840 m³/h, head up to 900 m, pressure 11 MPa, temp -196°C to +150°C.
Jiangsu Shuangda Pump Industry – VDD series: flow 20‑1,000 m³/h, head up to 1,000 m, pressure 15 MPa, temp -102°C to +250°C.
Kunming Jiahe Technology – JHDL series: vertical multistage barrel pump with canned design.
Hunan Perfect Industry – VS1/VS6 series: flow up to 8,800 m³/h, head up to 456 m, pressure 11 MPa.
Why Choose DL Series (VS6) for Deep Well Duty?
Full compliance with API 610 11th Edition Type VS6 – ensures maximum reliability and maintainability.
Double‑casing design provides secondary pressure containment – critical for hazardous or high‑pressure applications.
Low NPSHR via anti‑cavitation first stage – prevents cavitation in deep wells with limited submergence.
Wide hydraulic coverage – flow 20‑5,500 m³/h, head up to 1,000+ m.
Excellent high‑temperature capability – up to +250°C.
Low‑temperature option – as low as -196°C for cryogenic services.
Flexible material selection – carbon steel, stainless steel, duplex, and bronze to suit water, brine, or hydrocarbon duties.
Cost‑effective alternative to imported VS6 pumps – at competitive lead times.
For more information on selecting the correct DL series VS6 deep well pump, please contact us at info@hyrig.com.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.