This Ammonia Water Sump Pump is designed and manufactured in China to fully comply with API 610 (ISO 13709) 11th edition, VS4 or VS5 Pump configuration – vertical, single-stage, wet pit, cantilever design with bearings located above the cover plate. VS4 is a rigid shaft pump for shorter sump depths (typically ≤6 meters). VS5 is a longer flexible shaft pump with intermediate bearings for depths exceeding 6 meters. Both configurations are engineered for reliable pumping of ammonia water (ammonium hydroxide solution) from underground tanks, pits, sumps, and process drain basins in chemical fertilizer plants, refineries, and industrial wastewater systems.
Why Ammonia Water Sump Service Requires API 610 VS4/VS5
Ammonia water is mildly corrosive, releases ammonia vapor, and often contains trace solids or scale. It may be handled intermittently. The VS4/VS5 design provides:
No submerged bearings – all bearings above the liquid level
Seal-less operation – no mechanical seal to leak or fail
Corrosion resistant materials for ammonium hydroxide service
Ability to handle solids and debris
Safe containment of ammonia vapor with optional purge connections
Key Mechanical Features (VS4)
Rigid shaft with bearings above cover plate – no intermediate bearings
Suitable for sump depths up to 6 meters (20 ft)
Bearings: heavy duty grease or oil lubricated
Open or semi-open impeller – handles solids up to 20 mm
Flanged column pipe and discharge piping
Key Mechanical Features (VS5)
Extended shaft with one or more intermediate sleeve bearings (bushings) inside column pipe
Suitable for sump depths from 6 to 12 meters (20–40 ft) or more
Intermediate bearings lubricated by pumped liquid (ammonia water)
Flexible design accommodates longer depths while maintaining rotor stability
Performance Range
| Parameter | VS4 | VS5 |
|---|---|---|
| Flow rate | up to 1,000 m³/h | up to 1,500 m³/h |
| Head | up to 120 m | up to 150 m |
| Temperature | up to 80°C (higher on request) | up to 80°C |
| Sump depth | 1 – 6 meters | 4 – 12 meters |
| Design pressure | up to 1.6 MPa | up to 2.5 MPa |
Materials for Ammonia Water Service
Ammonia water (NH₄OH) is alkaline and can cause stress corrosion cracking in certain materials. Recommended wetted parts:
Stainless steel 316L (UNS S31603) – standard for dilute ammonia water
Duplex stainless steel (S31803/S32205) – for higher chloride content or elevated temperature
Titanium Grade 2 – for maximum corrosion resistance and long life
Non-metallic bearings (carbon/PTFE/silicon carbide) for VS5 intermediate bushings
Carbon steel is generally NOT recommended for ammonia water due to corrosion and contamination concerns.
Sealing and Vapor Containment
No mechanical seal is used. The shaft penetrates the cover plate through a throat bushing or labyrinth seal. For ammonia water service, a vapor seal or purge connection can be provided to prevent ammonia gas escape. Optional packing or a small gas barrier may be added for volatile services.
Bearing and Lubrication (Above Plate Bearings)
VS4 and VS5 share the same bearing housing located above the cover plate:
Grease lubrication – standard for intermittent duty
Oil bath or oil mist – for continuous heavy duty operation
Cooling fan or jacket – for higher temperature applications
VS5 intermediate bearings are lubricated by the pumped liquid (ammonia water), requiring proper material selection (corrosion resistant and wear resistant).
Quality and Testing
Each Ammonia Water Sump Pump is hydrostatically tested, performance tested, and mechanically run‑in per API 610. Rotating assembly dynamically balanced. Intermediate bearings (VS5) tested for fit and alignment. NPSH test available upon request.
Typical Applications
Ammonia water sump pump in fertilizer plants (urea, ammonium nitrate)
Underground tank unloading for ammonium hydroxide storage
Chemical pit drainage in refineries and petrochemical facilities
Wastewater neutralization sumps where ammonia is present
Spill collection and transfer in ammonia handling areas
VS4 vs VS5 Selection Guide
| Sump Depth | Recommended Configuration |
|---|---|
| ≤ 6 meters | VS4 – rigid shaft, no intermediate bearings |
| 6 – 12 meters | VS5 – flexible shaft with intermediate bushings |
| > 12 meters | Custom design (multiple intermediate bearings) |
Safety Features for Ammonia Service
Closed cover plate with gaskets to minimize vapor release
Purge connection for inert gas blanket
Explosion-proof motor option for hazardous area (ammonia is toxic but not highly flammable; still may require proper classification)
Complete Pump Package
We supply the Ammonia Water Sump Pump with vertical motor (TEFC or explosion proof), cover plate, column pipe, impeller, strainer, baseplate, and all necessary hardware – from a single source. Complete documentation including material certifications and NACE compliance (if required).
Contact
For engineering data, material recommendations, or a quotation for your ammonia water sump application, please contact info@hyrig.com.