This Vertical Sump Pump is designed and manufactured in China to fully comply with API 610 (ISO 13709) 11th edition, VS4 Pump configuration – vertical, single-stage, rigid shaft, wet pit, cantilever design with bearings above the cover plate. It is specifically engineered for reliable pumping from underground tanks, sumps, pits, trenches, and drain basins in refineries, chemical plants, wastewater facilities, and industrial complexes.
Why Sump Service Requires an API 610 VS4 Pump
Sump and pit applications often involve liquids with solids, abrasive particles, corrosive chemicals, high temperatures, or intermittent operation. The VS4 Pump design provides:
No submerged bearings – bearings located above the cover plate for easy maintenance
Seal-less design – no mechanical seal or gland packing required
Long shaft length – reaches deep sumps (up to 6 meters or more)
Solids handling – open or semi-open impellers tolerate sand, debris, and sludge
Vertical orientation – occupies minimal floor space with motor at top
Key Mechanical Features
Rigid shaft with above‑plate bearings – eliminates need for bottom bearings
Bearings: heavy duty deep groove ball or angular contact bearings, grease or oil lubricated
Open or semi‑open impeller – handles up to 10% solids by volume
Discharge through column pipe extending to cover plate
Flanged suction or strainer – prevents large debris entry
Dual volute optional for reduced radial thrust
Performance Range
| Parameter | Value |
|---|---|
| Flow rate | up to 1,500 m³/h |
| Head | up to 150 m |
| Temperature | up to 150°C (higher with cooling) |
| Sump depth | up to 6 meters (custom up to 12 meters) |
| Maximum solids size | up to 25 mm |
Materials for Sump Service
Carbon steel – for clean water or non‑corrosive liquids
Stainless steel 304 / 316 – for corrosive sumps (chemicals, acids)
Duplex (S31803/S32205) – for brackish water or chlorides
Alloy 20 or titanium – for highly aggressive chemicals
Wear plates and hardened materials – for abrasive slurries
Sealing System
No mechanical seal is required because the liquid level is below the cover plate. The shaft penetrates the cover plate with a throat bushing or labyrinth seal to minimize vapor escape and protect bearings. Optional purge connection for volatile or hazardous services.
Bearing and Lubrication
Bearings are located above the cover plate, accessible without removing the pump from the sump. Grease lubrication is standard. Oil bath or oil mist lubrication available for continuous heavy duty operation. Bearing housing with cooling fan for high temperature applications.
Quality and Testing
Each Vertical Sump Pump is hydrostatically tested, performance tested, and mechanically run‑in per API 610. Dynamic balancing of rotating assembly. Vibration and bearing temperature monitoring optional.
Typical Applications
Underground tank and pit drainage in refineries and chemical plants
Process sump pump for collecting leaks and spills
Cooling tower basin pump
Wastewater lift station and sewage sumps
Mine dewatering and quarry pit drainage
Chemical sump transfer – acids, caustics, solvents
Seal‑Less Advantage
The VS4 cantilever design eliminates mechanical seal failures – a common problem in sump applications. This reduces maintenance costs and prevents leakage to the environment.
Complete Pump Package
We supply the Vertical Sump Pump with vertical electric motor (TEFC or explosion proof), motor support bracket, discharge column pipe, baseplate or cover plate, strainer, and necessary hardware – all from a single source.
Contact
For engineering data, material recommendations, or a quotation for your sump or underground tank application, please contact info@hyrig.com.