Our API 610 antiscalant pumps are heavy‑duty centrifugal pumps engineered specifically for the precise, reliable injection of antiscalant chemicals in water treatment plants, cooling water systems, reverse osmosis (RO) units, oilfield operations, boilers, and industrial processes where scale formation and fouling must be controlled. Antiscalants – also known as scale inhibitors – are chemical agents used to prevent the precipitation and deposition of mineral scales (calcium carbonate, calcium sulfate, barium sulfate, silica, etc.) on equipment surfaces, heat exchangers, membranes, and pipelines. These chemicals are typically injected in small, controlled doses at high pressures to ensure effective dispersion and prevention of scale formation. Pumps for this service demand accurate flow control, corrosion resistance to chemical attack, reliable sealing, and consistent performance under continuous or intermittent operation. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for maximum safety, reliability, and longevity in the most demanding chemical injection applications. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – with selection based on flow rate, head, NPSH availability, and installation requirements.
API 610 Classifications for Antiscalant Duties
BB – Between Bearings Pumps
For main high‑capacity antiscalant injection and transfer duties, BB pumps provide superior rotor stability and long‑term reliability. BB1 (axially split, double‑suction) and BB2 (radially split, single‑stage or two‑stage) configurations are commonly specified for flows from 10 to 500 m³/h and heads up to 300 metres. The between‑bearings arrangement minimises shaft deflection, extending seal and bearing life – critical for continuous, accurate injection operations. Double‑suction designs (BB1) balance axial thrust at high flows.
OH – Overhung Pumps
For moderate‑capacity antiscalant injection, booster duties, or smaller systems, OH pumps offer a compact and cost‑effective solution. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes are widely used for antiscalant injection in RO systems, cooling water treatment, and small‑scale industrial applications. Centreline mounting accommodates thermal expansion. Their back‑pull‑out design allows easy seal and impeller maintenance without disturbing piping. Single‑stage OH pumps handle flows up to 200 m³/h and heads up to 250 metres.
VS – Vertically Suspended Pumps
In applications where antiscalant is drawn from low‑NPSH storage tanks, sumps, or underground reservoirs, VS pumps provide excellent suction performance. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the impeller below the liquid level, eliminating cavitation and priming problems. Their vertical footprint saves valuable plot space.
Key Performance & Design Features
Flow Range – Capacities from 0.5 m³/h to 500 m³/h, covering all antiscalant injection requirements.
Head Range – Up to 350 metres for high‑pressure injection duties.
Temperature Range – Designed for antiscalants from ambient to 60°C (140°F), with appropriate material selection.
Chemical Compatibility – Wetted parts manufactured from stainless steels (304L, 316L, duplex), high‑alloy materials, and corrosion‑resistant coatings to withstand chemical attack from antiscalant formulations.
Injection Accuracy – Precision hydraulic design and optional VFD integration for accurate, consistent chemical dosing.
Sealing – API 682 mechanical seals – single or dual (tandem) seals depending on service requirements. Suitable flush plans (Plan 11, 13, 32, 53A/B) with cooling to maintain seal integrity.
Casing Design – Robust casings with replaceable wear rings; smooth internal surfaces to minimise chemical degradation and fouling.
Bearing & Lubrication – Heavy‑duty bearings (oil or grease lubricated) with temperature and vibration monitoring for predictive maintenance.
Impeller Options – Closed impellers for efficient handling; special hydraulics for low‑flow, high‑head injection duties.
Material Traceability – All wetted materials are fully traceable with certified mill test reports (MTRs).
Typical Applications
Antiscalant injection in reverse osmosis (RO) and membrane systems
Scale inhibitor dosing in cooling water towers and recirculating systems
Antiscalant injection in oilfield waterflood operations and produced water treatment
Chemical injection for boiler feed water treatment
Scale prevention in heat exchangers and process equipment
Water treatment in power generation and desalination plants
Industries Served
Water and wastewater treatment
Oil refineries and petrochemicals
Oil and gas production (waterflooding)
Power generation (cooling water treatment)
Chemical processing
Desalination plants
Pulp and paper
Why Choose Our Antiscalant Pumps?
With extensive experience in chemical injection and full API 610 compliance, we design and manufacture antiscalant pumps that combine reliability, accuracy, and corrosion resistance. Every pump undergoes rigorous performance testing, hydrostatic testing, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet international specifications. We offer customised hydraulic designs, material selections, and sealing arrangements to match your specific antiscalant formulation, injection pressure, and flow requirements. Our engineering support includes NPSH analysis, API 684 rotor dynamics, material compatibility evaluation, and system integration advice to ensure long‑term, trouble‑free operation.
Contact Us
For technical datasheets, selection assistance, or a customised quotation, please contact us at:
info@hyrig.com
Rely on our API 610 antiscalant pumps to deliver accurate, reliable chemical injection for your critical scale prevention programmes.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.