Our API 610 water injection pumps are available in BB, OH, and VS designs, specifically engineered for the reliable injection and transfer of deaerated water in boiler feed systems, enhanced oil recovery (EOR), power generation, and industrial water management applications. BB pumps provide superior rotor stability for high‑flow, high‑pressure main injection duties. OH pumps offer compact solutions for smaller injection or booster services, while VS pumps handle low‑NPSH suction from deaerator storage tanks. Built with stainless steel and corrosion‑resistant materials to maintain water purity and resist corrosion from oxygen‑free water. Fully API 610/ISO 13709 compliant for reliable, long‑life deaerated water injection service.

Conatct For Details
DetailReview(0)Additional

Our API 610 water injection pumps are heavy‑duty centrifugal pumps engineered specifically for the reliable injection and transfer of deaerated water in boiler feed systems, enhanced oil recovery (EOR), power generation, chemical processing, and industrial water management applications. Deaerated water – water that has been stripped of dissolved oxygen and other corrosive gases – is used as injection water to prevent corrosion in high‑pressure systems, to maintain reservoir pressure in oil recovery, and as boiler feed water in thermal power plants. The deaerated water is characterised by low dissolved oxygen content (typically < 7 ppb), elevated temperatures (up to 100‑150°C), and aggressive corrosivity to carbon steel due to its low mineral content. Pumps for this service must deliver reliable performance with absolute integrity, corrosion resistance, and dependable operation under continuous, high‑duty injection conditions. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for maximum safety, reliability, and longevity in the most demanding injection applications. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – with selection based on flow rate, head, NPSH availability, and installation requirements.

API 610 Classifications for Water Injection Duties

  • BB – Between Bearings Pumps
    For main high‑capacity deaerated water injection and transfer duties, BB pumps provide superior rotor stability and long‑term reliability. BB1 (axially split, double‑suction) and BB2 (radially split, single‑stage or two‑stage) configurations are commonly specified for flows from 50 to 4,000 m³/h and heads up to 300 metres. The between‑bearings arrangement minimises shaft deflection, extending seal and bearing life – critical for continuous, high‑duty injection operations. Double‑suction designs (BB1) balance axial thrust at high flows.

  • OH – Overhung Pumps
    For moderate‑capacity water injection, booster duties, or smaller systems, OH pumps offer a compact and cost‑effective solution. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes are widely used for deaerated water injection in smaller‑scale EOR, boiler feed make‑up, and industrial water transfer applications. Centreline mounting accommodates thermal expansion. Their back‑pull‑out design allows easy seal and impeller maintenance without disturbing piping. Single‑stage OH pumps handle flows up to 1,500 m³/h and heads up to 180 metres.

  • VS – Vertically Suspended Pumps
    In applications where deaerated water is drawn from low‑NPSH deaerator storage tanks, sumps, or underground reservoirs, VS pumps provide excellent suction performance. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the impeller below the liquid level, eliminating cavitation and priming problems. Their vertical footprint saves valuable plot space.

Key Performance & Design Features

  • Flow Range – Capacities from 5 m³/h to 5,000 m³/h, covering all water injection requirements.

  • Head Range – Up to 350 metres for high‑head injection to elevated systems.

  • Temperature Range – Designed for deaerated water from ambient to 150°C (302°F), with appropriate material selection.

  • Water Quality Preservation – Wetted parts manufactured from stainless steels (304L, 316L, duplex) and corrosion‑resistant materials to prevent contamination of deaerated water. Internal electropolished surfaces available to minimise particle shedding.

  • Corrosion Resistance – Materials selected to withstand the aggressive nature of low‑mineral, oxygen‑free water.

  • Sealing – API 682 mechanical seals – single or dual (tandem) seals depending on service requirements. Suitable flush plans (Plan 11, 13, 23, 32) with cooling to maintain seal integrity. Packed glands are generally avoided to maintain water purity.

  • Casing Design – Robust casings with replaceable wear rings; smooth internal surfaces to minimise scale deposition.

  • Bearing & Lubrication – Heavy‑duty bearings (oil or grease lubricated) with temperature and vibration monitoring for predictive maintenance.

  • Impeller Options – Closed impellers for efficient handling; corrosion‑resistant coatings for enhanced durability.

  • Driver Options – Compatible with electric motors (VFD‑ready), diesel engines, and turbine drives.

Typical Applications

  • Deaerated water injection for boiler feed make‑up systems

  • Deaerated water injection for enhanced oil recovery (EOR) and reservoir pressure maintenance

  • High‑purity water transfer in power generation (cooling and make‑up)

  • Industrial process water injection and circulation

  • Chemical dilution and reagent mixing water supply

  • Deaerated water transfer in refinery and petrochemical processes

Industries Served

  • Oil refineries and petrochemicals (process water injection)

  • Power generation (boiler feed and cooling water)

  • Chemical manufacturing (pure water handling)

  • Enhanced oil recovery (EOR) projects

  • Industrial water treatment facilities

  • Pharmaceutical and biotechnology

Why Choose Our Water Injection Pumps?

With extensive experience in deaerated water handling and full API 610 compliance, we design and manufacture water injection pumps that combine reliability, efficiency, and water quality protection. Every pump undergoes rigorous performance testing, hydrostatic testing, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet international specifications. We offer customised hydraulic designs, material selections, surface finishes, and sealing arrangements to match your specific water quality requirements, temperature, and duty point. Our engineering support includes NPSH analysis, material compatibility evaluation, and system integration advice to ensure seamless, contamination‑free operation.

Contact Us

For technical datasheets, selection assistance, or a customised quotation, please contact us at:

info@hyrig.com

Rely on our API 610 water injection pumps to deliver deaerated water reliably and safely for your critical injection and process systems.