API 610 liquid ammonia pump series, manufactured in China. Includes BB2 and VS4 models. Flow range 10–1700 m³/h, head up to 1000 m, temperature -33°C to +40°C, pressure up to 5.0 MPa (BB2) and 15.0 MPa (VS4). Designed for handling anhydrous liquid ammonia in fertilizer plants, refrigeration systems, power plant DeNOx (SCR), chemical synthesis, and storage terminals. Features low NPSH design (VS4 vertical barrel with inducer for deep cavern extraction), low‑temperature carbon steel (LCB/LCC) or 316L stainless steel (fully impact tested to -46°C), API 682 dual mechanical seals (Plan 53B) with barrier fluid to prevent toxic ammonia leakage, and heavy-duty construction. BB2 single‑stage radial split for moderate pressure transfer, VS4 vertical barrel for low NPSH and high head cavern/sump extraction. API 610 compliant, 30-year design life, NACE optional for sour service.
Conatct For Details
DetailReview(0)Additional

Product Overview

Are you searching for a China-made API 610 pump suitable for liquid ammonia applications?
This series includes BB2, VS4 models, strictly manufactured according to the latest API 610 (centrifugal pumps for petroleum, petrochemical, and natural gas industries) standard, engineered for anhydrous liquid ammonia (NH₃) service – stored either as pressurized liquid at ambient temperature (approximately 1.0 MPa at 20°C) or refrigerated at -33°C under atmospheric pressure. Typical applications include: ammonia transfer from storage spheres or refrigerated tanks to process units, fertilizer plant feed (urea, ammonium nitrate), power plant DeNOx (SCR) injection, industrial refrigeration circulation, marine/road terminal loading, and underground cavern extraction.

With specialized low‑NPSH inducers (VS4), dual pressurized mechanical seals (API 682 Plan 53B) to prevent toxic ammonia emissions, low‑temperature carbon steel or stainless steel construction (fully impact tested to -46°C), and heavy‑duty bearings, our pumps provide safe, reliable, long‑life (≥30 years) operation for this hazardous, corrosive (to copper‑based alloys), and environmentally sensitive fluid.

Core Advantages

  • Full API 610 Compliance – Designed and manufactured per API 610 latest edition for BB2 and VS4 constructions. Passed strict dynamic balancing, hydrostatic, low‑temperature impact (where applicable), and helium leak testing. Design life ≥30 years, continuous trouble‑free operation ≥3 years.

  • Optimized for Low NPSH & Ammonia's High Vapor Pressure – VS4 vertical barrel pump with inducer achieves extremely low NPSH (as low as 0.5‑1.5 m), essential for extracting liquid ammonia from underground caverns or low liquid level refrigerated tanks. BB2 can be fitted with oversize first‑stage impeller for moderate NPSH requirements.

  • Moderate & High Pressure Capabilities – BB2 (single‑stage radial split, ≤5.0 MPa, head ≤250 m) for transfer, loading, and general circulation. VS4 (vertical multi‑stage barrel, up to 15.0 MPa, head up to 1000 m) for high head, low NPSH applications such as cavern extraction and high‑pressure injection.

  • Materials for Low Temperature & Stress Corrosion Cracking Prevention – Standard for -33°C to -45°C: low‑temperature carbon steel (A352 LCB/LCC) fully impact tested to -46°C. For higher purity or resistance to stress corrosion cracking (ammonia can cause SCC in carbon steel under certain conditions), 316L stainless steel is recommended. All wetted parts are free of copper, zinc, or their alloys (brass, bronze) to prevent corrosion. NACE MR0175 optional for sour ammonia.

  • Advanced Sealing for Toxic Ammonia – API 682 dual mechanical seals (pressurized Plan 53B) with inert barrier fluid (e.g., ethylene glycol/water or clean mineral oil) eliminate fugitive emissions of toxic ammonia. Barrier pressure > process pressure ensures any leakage moves from barrier into process. Leak detection and alarm standard. Seal faces: tungsten carbide vs carbon with low‑temperature elastomers (FKM/FFKM).

  • Heavy‑Duty Rotor & Bearings – Rotors dynamically balanced (ISO 1940 G2.5). Bearings: high‑load rolling element or tilting‑pad with forced oil lubrication or oil mist. Vibration monitoring per API 670. Static grounding brushes to prevent charge accumulation.

  • Flexible Installation – Horizontal BB2 for above‑ground plants. Vertical VS4 for underground caverns, sumps, or refrigerated tank pits.

Main Models & Applications

BB2 (Single-stage, Double-suction, Radial Split)

Features: Horizontal single‑stage, double‑suction, radial split, centerline mounting – moderate pressure up to 5.0 MPa, head ≤250 m, balanced axial thrust, easy maintenance without removing piping.
Liquid ammonia applications: Transfer from bullet/sphere storage to vaporizers or process (urea, ammonium nitrate), truck/rail loading pumps, circulation in refrigeration systems (shell‑and‑tube chillers), feed to DeNOx injection skids (low pressure), pipeline booster.
Commonly searched as: single‑stage liquid ammonia pump / BB2 ammonia transfer pump.

VS4 (Vertical Suspended Multi-stage Diffuser Barrel Pump)

Features: Vertical multi‑stage, diffuser design, barrel‑type casing with inducer – extremely low NPSH (0.5‑1.5 m), ideal for deep cavern or sump extraction, head up to 1000 m, working pressure up to 15.0 MPa, immersed installation below liquid level.
Liquid ammonia applications: Underground salt cavern liquid ammonia extraction, refrigerated atmospheric storage tank sump pumping (where NPSH is critical), marine terminal unloading from deep well of ammonia carriers, high head injection into high‑pressure ammonia reactors (e.g., urea synthesis with high‑pressure ammonia feed – up to 15 MPa), high‑pressure pipeline transport over long distances.
Searches matched: vertical low NPSH liquid ammonia pump / VS4 ammonia cavern pump.

Performance Parameters Table

ModelFlow (m³/h)Head (m)Temp Range (°C)Working Pressure (MPa)Typical Stages
BB284–170065–250-33 to +40≤5.01
VS410–800*up to 1000-33 to +40≤15.0 (higher on request)2‑10

*VS4 flow range typical for liquid ammonia: up to 800 m³/h depending on size.

Material Configuration (Liquid Ammonia Service, -33°C)

ComponentStandard Low Temp MaterialSCC‑Resistant OptionNotes
Casing (BB2)Low temp carbon steel A352 LCB/LCC316L stainless steelImpact tested -46°C; avoid SCC
Outer barrel (VS4)Forged low‑temp steel (A350 LF2)316L or duplex
Inner stage casingLCB/LCC or CF8M (316L)316L
ImpellerLCB/LCC or CF8M316LClosed impeller
Shaft17‑4 PH (H1150) or 316L316LHardness controlled to avoid SCC
Wear rings17‑4 PH H1150 or stellite316L with coatingReplaceable
BoltingA320 L7 (low temp)A193 B8M (316)No copper alloys
SealAPI 682 Plan 53B dual mechanicalSameBarrier fluid: glycol/water or oil
BearingHigh‑load rolling, oil mistSame
GasketsSpiral wound graphite/316LPTFE
  • Critical: All wetted parts are copper‑free, zinc‑free, to avoid catastrophic corrosion with ammonia. No brass, bronze, or galvanized components.

  • For carbon steel construction in wet ammonia service, consideration of stress corrosion cracking (SCC) requires hardness control and post‑weld heat treatment per industry guidelines. Stainless steel 316L eliminates SCC risk.

FAQ – Frequently Asked Questions for Liquid Ammonia API 610 Pumps

Q: Which API 610 pump model is best for extracting liquid ammonia from an underground cavern (very low NPSH)?
A: VS4 vertical barrel pump with inducer – designed for NPSHa as low as 0.5 m, fully immersed in the cavern sump.

Q: Which model is recommended for high pressure ammonia feed to a urea reactor (15 MPa)?
A: VS4 multi‑stage vertical barrel pump can achieve up to 15 MPa (or more) with multiple stages. Also suitable for high head applications.

Q: Can a single‑stage BB2 be used for ammonia transfer from refrigerated storage?
A: Yes, for moderate head (≤250 m) and ambient to -33°C, BB2 with low‑temp carbon steel or stainless steel is ideal for transfer and loading.

Q: What materials should be used to avoid ammonia stress corrosion cracking?
A: 316L stainless steel is highly recommended. If using carbon steel (LCB/LCC), strict hardness control (≤225 HB) and PWHT are applied, and moisture content in ammonia must be kept low (>0.2% water inhibits SCC). We typically recommend 316L for critical or wet ammonia service.

Q: How do you prevent toxic ammonia emissions?
A: We provide API 682 dual pressurized mechanical seals (Plan 53B) with barrier fluid. Barrier pressure is higher than process pressure, so any leakage flows from barrier into the process, not to atmosphere. Continuous leak detection is standard.

Q: Are these pumps made in China?
A: Yes, we are a Chinese manufacturer certified to API 610, with extensive references in ammonia applications for fertilizer plants, power plants, and terminals.

Q: What is the design life and MTBF?
A: Design life ≥30 years, continuous trouble‑free operation ≥3 years for liquid ammonia service with proper maintenance and seal monitoring.

Why Choose Our API 610 Liquid Ammonia Pump Series?

  • Low NPSH capability – VS4 with inducer for caverns and refrigerated sumps.

  • High pressure options – VS4 up to 15 MPa for reactor feed.

  • SCC prevention – 316L stainless steel recommended.

  • Zero toxic emissions – API 682 Plan 53B dual seals.

  • Complete range – BB2 (transfer/loading), VS4 (low NPSH, high head).

  • China competitive pricing – premium safety features at affordable cost.

Contact Us

For inquiries, model selection, or technical support, please provide: ammonia service type (refrigerated at -33°C or pressurized ambient), flow (m³/h), differential head (m), suction pressure (minimum and normal), NPSHa available, required discharge pressure (MPa), expected moisture content in ammonia (to assess SCC risk), and installation type (horizontal or vertical sump/cavern). Our ammonia specialists will recommend the optimal API 610 liquid ammonia pump (BB2 or VS4) with safe material and sealing configuration.

Email: info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit