HYRIG's submerged cryogenic booster pump is specifically engineered for gas turbine co-generation (CHP) systems. This vertical, multistage centrifugal pump is fully submerged in LNG, ensuring zero leakage and continuous motor cooling by the cryogenic liquid. It is a critical component for supplying pressurized LNG fuel to gas turbines in power generation and co-generation applications.
The pump enables efficient fuel delivery by boosting LNG pressure to the levels required by gas turbine fuel systems. By pressurizing LNG in its liquid phase, the pump significantly reduces the compression power required compared with gas-phase compression, contributing to improved overall energy efficiency.
Fully Submerged, Seal‑Less Design – The pump and motor are combined as one entirely submerged unit, eliminating dynamic seals and providing absolute zero leakage of LNG. The motor operates in an oxygen-free cryogenic environment, removing the potential for ignition.
Compact Design for Smaller Systems – Specifically designed for smaller gas turbine and co-generation systems with a compact footprint, enabling installation in space-constrained power generation facilities.
Inverter Drive Compatibility – Features soft start and flexible speed control through inverter drive compatibility, allowing precise adjustment of pump operation to match system requirements and achieve energy savings.
Multistage High-Head Capability – The modular multistage design provides the differential pressure required for gas turbine fuel supply, with configurations available to meet diverse power generation requirements.
Automatic Axial Thrust Balancing – An automatic axial thrust balance mechanism minimizes bearing load for a prolonged service life.
High Efficiency – High pump efficiency due to reduced internal leakage, minimizing power consumption and operational costs.
Easy Maintenance – Simple, lightweight structure with minimized bearing load ensures easy maintenance.
Reliable Performance – Tested equipment ensures reliable pump performance, with test equipment capable of operating the pump with LNG at -162°C.
Fluid Handled: LNG (Methane), also suitable for Ethane, Propane, LPG
Configuration: Vertical, multistage, submerged centrifugal pump
Motor: Submerged motor, inverter drive compatible
Speed Control: Variable speed / inverter drive for flexible operation
Design: Compact for smaller gas turbine and co-generation systems
Applications: Gas turbine co-generation, power generation fuel supply, peaking power plants, distributed energy systems
Gas Turbine Co-Generation (CHP) Systems – Boosting LNG fuel pressure for gas turbines in combined heat and power plants
Power Generation – Fuel supply for gas turbine power plants
Industrial Co-Generation – LNG fuel boosting for industrial CHP installations
Peaking Power Stations – Reliable fuel supply during peak demand periods
Distributed Energy Systems – LNG fuel supply for decentralized power generation
Smaller Gas Turbine Installations – Compact design ideal for space-constrained turbine systems
Zero Leakage Safety – The fully submerged design eliminates the primary leak path, ensuring safe handling of LNG.
Energy Efficiency – Liquid-phase pumping significantly reduces compression power compared with gas-phase compression, improving overall system efficiency. Variable speed control further optimizes energy consumption.
Reduced Operating Costs – High pump efficiency due to reduced internal leakage minimizes power consumption.
Flexible Operation – Inverter drive compatibility enables soft start and flexible speed control to match varying system demands.
Low Maintenance – Simple, lightweight structure with minimized bearing load ensures easy maintenance and long service life.
Proven Reliability – Technology validated through extensive testing, including full-scale LNG testing at -162°C.
Every submerged cryogenic booster pump manufactured by HYRIG is produced under stringent quality management systems and supports the rigorous demands of gas turbine co-generation and power generation applications. The pump is tested with LNG at -162°C to ensure reliable performance.
Co-Generation Application Expertise – Specialized in submerged cryogenic pump solutions for gas turbine co-generation and power generation fuel supply
Zero-Leakage Safety – Fully submerged, seal‑less construction eliminates LNG leak risks
Compact, Space-Saving Design – Specifically engineered for smaller gas turbine and co-generation systems
Energy Efficient – Liquid-phase pumping and inverter drive compatibility minimize power consumption
Proven Technology – Backed by decades of engineering expertise in cryogenic pumping systems
Comprehensive Service – Full after-sales support including installation supervision, commissioning, and spare parts supply
For detailed technical data sheets, customized quotations, or to discuss your specific gas turbine co-generation booster pump requirements, please contact our engineering team at:
info@hyrig.com
Our cryogenic and power generation specialists are ready to provide professional consultation and tailored support for your project needs.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.