LPG Transfer Pump for LNG Calorie Adjustment | Submerged Cryogenic Pump | HYRIG

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
HYRIG manufactures a high-performance submerged cryogenic LPG transfer pump specifically engineered for LNG calorie adjustment applications. This vertical, multistage centrifugal pump is fully submerged in the cryogenic liquid, ensuring zero leakage and continuous motor cooling. Designed for precise LPG injection into LNG streams to adjust calorific value, the pump features automatic axial thrust balancing for prolonged bearing life, high efficiency due to reduced internal leakage, and easy maintenance. Ideal for LNG receiving terminals, gas utilities, and city gas networks requiring accurate heat value control. Tested with LNG at -162°C for reliable performance.

Conatct For Details
DetailReview(0)Additional

HYRIG's submerged cryogenic LPG transfer pump is specifically engineered for LNG calorie adjustment applications in LNG receiving terminals and gas utilities. This vertical, multistage centrifugal pump is fully submerged in the cryogenic liquid, ensuring zero leakage and continuous motor cooling by the pumped medium. It is a critical component for injecting LPG into LNG streams to adjust calorific value, ensuring that regasified natural gas meets the specified heat value requirements for downstream consumers.

LNG calorific value adjustment is essential because gas consumers require consistent energy content for efficient combustion and low environmental impact. Liquid-phase LPG injection has become the mainstream method for calorific value adjustment, and this pump enables precise, reliable transfer of LPG for this purpose.

Key Design Features

Fully Submerged, Seal‑Less Design – The pump and motor are combined as one entirely submerged unit, eliminating dynamic seals and providing absolute zero leakage of LPG. The motor operates in an oxygen-free cryogenic environment, removing the potential for ignition.

Automatic Axial Thrust Balancing – An automatic axial thrust balance mechanism minimizes bearing load, ensuring a prolonged service life and reliable operation.

High Efficiency – High pump efficiency due to reduced internal leakage, minimizing power consumption and operational costs.

Easy Maintenance – Simple, lightweight structure with minimized bearing load ensures easy maintenance and long service life.

Reliable Performance – Tested equipment capable of operating the pump with LNG at -162°C ensures reliable pump performance.

Multistage High-Head Capability – The modular multistage design provides the differential pressure required for precise LPG injection into LNG streams.

Technical Specifications

  • Fluid Handled: LPG (Propane, Butane, and mixtures), also suitable for LNG, Ethane, Ethylene

  • Configuration: Vertical, multistage, submerged centrifugal pump

  • Motor: Submerged motor

  • Sealing: Zero leakage (fully submerged design)

  • Applications: LNG calorie adjustment, LPG injection into LNG streams, LNG receiving terminals, city gas networks

  • Testing: Tested with LNG at -162°C for reliable performance

Key Applications

  • LNG Receiving Terminals – Injecting LPG into LNG streams to adjust calorific value before regasification

  • City Gas Networks – Ensuring natural gas meets specified heat value requirements for residential and industrial consumers

  • Gas Utilities – Precise LPG transfer for calorific value control in gas distribution systems

  • LNG Import Terminals – Heat value adjustment to match local gas specifications

Operational Advantages

Zero Leakage Safety – The fully submerged design eliminates the primary leak path, ensuring safe handling of LPG.

Precise Calorie Control – Enables accurate LPG injection into LNG streams for precise calorific value adjustment.

High Efficiency – Reduced internal leakage and optimized hydraulics minimize power consumption.

Low Maintenance – Simple, lightweight structure with minimized bearing load ensures easy maintenance and long service life.

Proven Reliability – Technology validated through extensive testing, including full-scale LNG testing at -162°C.

Quality Assurance & Certifications

Every submerged cryogenic LPG transfer pump manufactured by HYRIG is produced under stringent quality management systems and supports the rigorous demands of LNG receiving terminals and gas utility applications. The pump is tested with LNG at -162°C to ensure reliable performance.

Why Choose HYRIG?

  • Calorie Adjustment Expertise – Specialized in submerged cryogenic pump solutions for LNG calorific value control and LPG injection applications

  • Zero-Leakage Safety – Fully submerged, seal‑less construction eliminates LPG leak risks

  • High Performance – Multistage design provides precise flow control for accurate calorie adjustment

  • Proven Technology – Backed by decades of engineering expertise in cryogenic pumping systems

  • Comprehensive Service – Full after-sales support including installation supervision, commissioning, and spare parts supply

For detailed technical data sheets, customized quotations, or to discuss your specific LPG transfer pump for LNG calorie adjustment requirements, please contact our engineering team at:

info@hyrig.com

Our cryogenic specialists are ready to provide professional consultation and tailored support for your project needs.


Comment