HYRIG manufactures a high-performance submerged cryogenic LNG feed pump specifically engineered for bunkering stations and CNG refueling facilities. This vertical, multistage centrifugal pump is fully submerged in LNG, ensuring zero leakage and continuous motor cooling. Equipped with a permanent magnet motor and VFD for precise control, it delivers reliable, pressure-stabilized LNG transfer from storage tanks to dispensers or high-pressure systems. Ideal for LNG bunkering stations, CNG daughter stations, and vehicle refueling infrastructure. Tested with LNG at -162°C for reliable performance.

Conatct For Details
DetailReview(0)Additional

HYRIG's submerged cryogenic LNG feed pump is specifically engineered for bunkering stations and CNG refueling facilities. This vertical, multistage centrifugal pump is fully submerged in LNG, ensuring zero leakage and continuous motor cooling by the cryogenic liquid. It is a critical component for transferring LNG from storage tanks to dispensers or high-pressure systems in automotive and marine refueling applications.

The pump is installed at the bottom of the LNG tank, with all components fully submerged in the liquid. The LNG cryogenically cools the motor, and the pump is a direct-drive unit with the motor mounted in line with the pump shaft or integrated with it.

Key Design Features

Fully Submerged, Seal‑Less Design – The pump and motor are combined as one entirely submerged unit, eliminating dynamic seals and providing absolute zero leakage of LNG. The motor operates in an oxygen-free cryogenic environment, removing the potential for ignition.

Permanent Magnet Motor – Features a highly efficient and compact permanent magnet motor, which reduces the size and weight of the pump.

Variable Frequency Drive (VFD) Compatibility – Designed for wide operational capability through VFD use, allowing precise control over the entire pump operating range. VFD technology intelligently adjusts output flow and pressure based on refueling demand to achieve optimal balance between energy consumption and efficiency.

Multistage High-Head Capability – The modular multistage design provides the differential pressure required for bunkering and CNG station applications, with ratings available in 1, 2, 3, 4, or 6 stages. Some models can deliver flow rates up to 30 m³/h at 35 bar differential pressure.

Automatic Axial Thrust Balancing – An automatic axial thrust balance mechanism minimizes bearing load for a prolonged service life.

Extremely Low NPSH – Equipped with a helical inducer to minimize Net Positive Suction Head requirements, preventing cavitation issues.

High Efficiency – High pump efficiency due to reduced internal leakage, minimizing power consumption and operational costs.

Low Maintenance – Simple, lightweight structure with minimized bearing load ensures easy maintenance and long service life.

Reliable Performance – Tested equipment capable of operating the pump with LNG at -162°C ensures reliable pump performance.

Technical Specifications

  • Fluid Handled: LNG (Methane), also suitable for Ethane, Propane, LPG

  • Temperature Range: Down to -196°C

  • Configuration: Vertical, multistage, submerged centrifugal pump

  • Motor: Permanent magnet motor, VFD compatible

  • Flow Rate: Up to 546+ m³/h

  • Differential Pressure: Up to 55 bar

  • Speed Control: Variable frequency drive for precise control

  • Design: Compact for bunkering and CNG station installations

  • Testing: Tested with LNG at -162°C

Key Applications

  • LNG Bunkering Stations – Transferring LNG from storage tanks to bunkering vessels and receiving ships

  • CNG Daughter Stations – Feeding LNG to high-pressure pumps for conversion to CNG

  • LNG Vehicle Refueling Stations – Fuel transfer for LNG-powered trucks, buses, and passenger vehicles

  • LNG Dispenser Feed – Supplying LNG to dispensers for automotive refueling

  • LNG Fueling Skids – Integrated pump skid systems for mobile and stationary refueling applications

  • Containerized LNG Stations – Pump solutions for standardized containerized LNG refueling installations

Operational Advantages

Zero Leakage Safety – The fully submerged design eliminates the primary leak path, ensuring safe handling of LNG.

Cavitation Prevention – By utilizing an inducer, the pump eliminates cavitation issues that can reduce pump life.

High Efficiency – Optimized hydraulics and permanent magnet motor technology minimize power consumption.

Quick Start-Up – The pump remains constantly submerged in the cryogenic liquid so it is always ready to start, avoiding cooling-down downtimes.

Flexible Operation – VFD compatibility enables soft start and flexible speed control to match varying refueling demand.

Low Maintenance – Simple, lightweight structure with minimized bearing load ensures easy maintenance and long service life.

Proven Reliability – Technology validated through extensive testing, including continuous operation and start-stop cycles representing real-world use.

Quality Assurance & Certifications

Every submerged cryogenic LNG feed pump manufactured by HYRIG is produced under stringent quality management systems and supports the rigorous demands of bunkering and CNG station applications. The pump is tested with LNG at -162°C to ensure reliable performance.

Why Choose HYRIG?

  • Bunkering & CNG Application Expertise – Specialized in submerged cryogenic pump solutions for LNG refueling and CNG station applications

  • Zero-Leakage Safety – Fully submerged, seal‑less construction eliminates LNG leak risks

  • High Performance – Multistage design provides precise flow control for accurate refueling operations

  • Energy Efficient – Permanent magnet motor and VFD compatibility minimize power consumption

  • Proven Technology – Backed by decades of engineering expertise in cryogenic pumping systems

  • Comprehensive Service – Full after-sales support including installation supervision, commissioning, and spare parts supply

For detailed technical data sheets, customized quotations, or to discuss your specific LNG feed pump for bunkering/CNG station requirements, please contact our engineering team at:

info@hyrig.com

Our cryogenic specialists are ready to provide professional consultation and tailored support for your project needs.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit