| Item | Range | P/N | Description |
|---|---|---|---|
| 1 | 2 3/8" - 2 7/8" | 644501-07TU-FLEX | Flex Packer |
| Condition | Action |
|---|---|
| You are running pipe sizes between 2 3/8" and 2 7/8" | Use the Flex Packer to minimize the need for frequent ram changes |
| You are operating in high-temperature wells | Specify HNBR or FKM elastomer to prevent flex fatigue |
Common field error: Using a Flex Packer for pipe sizes outside its designed range (e.g., attempting to seal 3 1/2" pipe), which causes severe extrusion and seal failure.
For Cameron Type U 7 1/16" Flex Packers, email info@hyrig.com with:
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.