1. Product Overview
The OH2 Series Caustic Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 (ISO 13709) international standards. It is purpose-built for handling strong alkaline media such as sodium hydroxide (NaOH), potassium hydroxide (KOH), and sodium carbonate (Na₂CO₃) in chlor‑alkali chemical, synthetic fiber, papermaking, electroplating, and flue gas desulfurization (FGD) applications. Designed for concentrations from 5% to 50% and temperatures from -10°C to 120°C, it achieves long‑term continuous operation (annual operation rate ≥99.7%) and is a critical equipment for caustic circulation, transfer, and injection.
Model Code Interpretation (OH2):
O = Overhung: Impeller outside bearing housing – compact structure, facilitates corrosion‑resistant sealing.
H = Horizontal: Horizontal mounting, compatible with caustic system layouts.
2 = 2nd Generation: Centerline support design – superior thermal stability for caustic temperature fluctuations.
2. Key Structural Features (Caustic‑Specific Design)
Strong Alkali Corrosion Resistant Material System: Wetted parts standard 316L / 316Ti stainless steel (alkali‑resistant, anti‑intergranular corrosion). For high concentration (>30%) or high temperature (>80°C), use 2205 / 2507 duplex steel. For chloride‑containing caustic, select Hastelloy C‑276 / Incoloy 825. Shaft material 316Ti / duplex steel, shaft sleeve silicon carbide / Hastelloy – eliminates alkali corrosion and stress cracking.
Anti‑Crystallization Flow Path Design: Wide‑channel, low‑shear, large‑clearance impeller, CFD‑optimized to prevent crystallization blockage. Pump casing flow path polished to Ra ≤0.8 μm to reduce alkali scale adhesion. Inlet with anti‑vortex stabilization section, outlet with double volute (≥DN80) to balance radial forces – adapted to caustic’s high crystallization tendency.
Caustic‑Dedicated Sealing System: Standard API 682 Type 21/22 double mechanical seals. Friction pairs: silicon carbide + silicon carbide (alkali‑resistant, wear‑resistant). Seal chamber with FKM / perfluoroelastomer O‑rings (alkali swell‑resistant). For normal service: Plan 52; for high temperature / high concentration: Plan 54 with external clean water flush to prevent caustic crystallization from damaging seal faces – seal life ≥12,000 hours.
Centerline Mounting Thermal Stability: Pump casing centerline‑positioned, minimal thermal deformation from -10°C to 120°C – shaft runout ≤0.02 mm. Rigid shaft design (SFI ≤0.3), high‑temperature/high‑viscosity deflection ≤0.05 mm – vibration resistant, preventing seal leakage.
Leak‑Proof Back Pull‑Out Design: Back pull‑out construction allows rotor removal without disconnecting piping or motor – convenient for cleaning caustic scale and replacing seals, suitable for continuous operation.
3. General Technical Specifications
| Parameter | Value |
|---|---|
| Capacity | 5 – 2,600 m³/h (customizable to 3,000 m³/h) |
| Head | 20 – 320 m (max. 1,050 ft) |
| Operating Temperature | -10°C to 120°C (standard 80°C; high‑temp version 150°C) |
| Concentration | 5% – 50% NaOH / KOH |
| Inlet Pressure | ≤0.3 MPa; Outlet Pressure ≤10.0 MPa |
| Media Viscosity | 1 – 50 mm²/s (dependent on concentration/temperature) |
| Material Options | 316L, 316Ti, 2205 duplex, Hastelloy C‑276 |
| Explosion Protection | Ex d IIB T4 (Zone 1/2) |
| Speed | 50Hz: 1,450/2,900 rpm; 60Hz: 1,750/3,500 rpm |
| Flange Rating | Class 150/300/600# (RF, ASME B16.5) |
| Standards | API 610 12th, GB/T 3215, NACE MR0175 (optional) |
4. Global Equivalent Models (API 610 OH2 for Caustic)
| Brand | Series / Models | Key Adaptation |
|---|---|---|
| Sulzer | OHH‑C (40-250, 65-315, 100-400) | Chlor‑alkali dedicated, duplex standard, anti‑crystallization flow, life ≥15,000 h |
| Flowserve | HPX‑C (310, 410, 510) | High‑temp / high‑concentration caustic, Plan 54 flush – alkali recovery systems |
| KSB | KZE‑C (65-200, 80-250) | High efficiency, low noise, caustic wash tower circulation, NPSHr ≤2.8 m |
| Amarinth | OH2 custom | Hastelloy / Incoloy for chloride‑rich caustic |
5. Complete OH2 Caustic Pump Model Lineup (20 Core Models by Size)
Small Bore (DN40/DN50 – Small Flow, Circulation / Dosing)
Caustic Pump 40-250 OH2 – API 610 OH2, DN40, 250mm impeller, high pressure small flow. Capacity/Head: 25–50 m³/h / 80–110 m. Power: 18.5 kW. Application: Chlor‑alkali small flow circulation, reagent dosing.
Caustic Pump 50-160 OH2 – DN50, 160mm impeller, general small flow. Capacity/Head: 30–60 m³/h / 35–50 m. Power: 11 kW. Application: Small caustic tank farm transfer, electroplating bath circulation.
Caustic Pump 50-200 OH2 – DN50, 200mm impeller, standard. Capacity/Head: 30–65 m³/h / 50–70 m. Power: 15 kW. Application: Fiber caustic wash tower circulation, papermaking black liquor transfer.
Caustic Pump 50-250 OH2 – DN50, 250mm impeller, high pressure. Capacity/Head: 30–65 m³/h / 80–115 m. Power: 22 kW. Application: High‑concentration caustic boosting, small batch transfer.
Medium Bore (DN65/DN80 – Medium Flow, Mainstream Duty)
Caustic Pump 65-160 OH2 – DN65, 160mm impeller, medium flow low pressure. Capacity/Head: 50–100 m³/h / 32–48 m. Power: 18.5 kW. Application: Medium chlor‑alkali unit, FGD caustic circulation.
Caustic Pump 65-200 OH2 – DN65, 200mm impeller, medium flow general. Capacity/Head: 50–110 m³/h / 48–72 m. Power: 30 kW. Application: Caustic evaporator feed, chemical alkali wash system.
Caustic Pump 65-250 OH2 – DN65, 250mm impeller, medium flow high pressure. Capacity/Head: 50–110 m³/h / 75–110 m. Power: 45 kW. Application: Long‑distance caustic pipeline, high‑floor supply.
Caustic Pump 65-315 OH2 – DN65, 315mm impeller, medium flow ultra‑high head. Capacity/Head: 45–100 m³/h / 120–160 m. Power: 75 kW. Application: High‑pressure caustic injection, scrubber atomizing feed.
Caustic Pump 80-160 OH2 – DN80, 160mm impeller, large flow low pressure. Capacity/Head: 80–160 m³/h / 30–48 m. Power: 37 kW. Application: Large chlor‑alkali plant circulation, paper alkali recovery main pump.
Caustic Pump 80-200 OH2 – DN80, 200mm impeller, main duty. Capacity/Head: 80–160 m³/h / 48–72 m. Power: 55 kW. Application: Caustic concentration system, fiber plant alkali transfer.
Caustic Pump 80-250 OH2 – DN80, 250mm impeller, large flow medium‑high pressure. Capacity/Head: 80–160 m³/h / 75–115 m. Power: 90 kW. Application: High‑temp high‑concentration caustic, evaporation circulation.
Caustic Pump 80-315 OH2 – DN80, 315mm impeller, large flow high pressure. Capacity/Head: 75–150 m³/h / 120–165 m. Power: 132 kW. Application: Ultra‑high pressure caustic transfer, large FGD unit main pump.
Large Bore (DN100/DN125/DN150 – Large Flow, Industrial Scale)
Caustic Pump 100-200 OH2 – DN100, 200mm impeller, very large flow. Capacity/Head: 120–220 m³/h / 45–70 m. Power: 75 kW. Application: Large chlor‑alkali base, plant‑wide caustic circulation.
Caustic Pump 100-250 OH2 – DN100, 250mm impeller, very large flow medium pressure. Capacity/Head: 120–220 m³/h / 70–110 m. Power: 160 kW. Application: 10+ Mt/y refining desulfurization, large paper alkali recovery.
Caustic Pump 100-315 OH2 – DN100, 315mm impeller, very large flow high pressure. Capacity/Head: 120–220 m³/h / 115–160 m. Power: 250 kW. Application: High‑concentration caustic concentration, coal chemical alkali wash.
Caustic Pump 100-400 OH2 – DN100, 400mm impeller, very large flow ultra‑high head. Capacity/Head: 110–210 m³/h / 180–240 m. Power: 400 kW. Application: Ultra‑large chlor‑alkali unit, cross‑regional caustic pipeline network.
Caustic Pump 125-250 OH2 – DN125, 250mm impeller, giant flow. Capacity/Head: 200–350 m³/h / 65–100 m. Power: 200 kW. Application: National chemical park, large fiber base caustic main pump.
Caustic Pump 125-315 OH2 – DN125, 315mm impeller, giant flow high pressure. Capacity/Head: 200–350 m³/h / 110–155 m. Power: 315 kW. Application: Ultra‑large caustic soda plant, global top paper alkali recovery pump.
Caustic Pump 150-315 OH2 – DN150, 315mm impeller, extra‑large flow. Capacity/Head: 300–550 m³/h / 90–140 m. Power: 450 kW. Application: World‑class chlor‑alkali hub, large refining desulfurization main pump.
Caustic Pump 150-400 OH2 – DN150, 400mm impeller, top large flow high pressure. Capacity/Head: 300–550 m³/h / 160–220 m. Power: 630 kW. Application: Global top chemical base, ultra‑large caustic transfer project.
6. Selection Notes (Caustic‑Specific)
Material grading: ≤30% NaOH, ≤80°C → 316L; >30% or >80°C → 2205 duplex steel; Cl⁻ >500 ppm → Hastelloy C‑276.
Anti‑crystallization design: Prefer wide‑channel, large‑clearance impeller. For temperatures below 60°C, use heat tracing to prevent caustic crystallization and pump blockage.
Seal flush: For ≥80°C or ≥30% concentration, Plan 54 with clean water flush is mandatory – Plan 52 may cause crystallization.
Cavitation control: High caustic temperature raises vapor pressure – ensure NPSHa ≥ NPSHr + 1.0 m; enlarge suction pipe diameter or lower pump installation height if needed.
Power margin: Caustic viscosity varies significantly with concentration/temperature – motor power margin ≥15% to avoid overload.
7. Contact Us
For detailed technical datasheets, model selection assistance (free selection report with caustic type, concentration, temperature, Cl⁻ content, system pressure), 3D models (STEP/IGES), certification documents (API 610, material test reports, NACE MR0175), and customized solutions (high‑temp, high‑concentration, chloride‑resistant, leak‑free magnetic drive), please contact: