Amine Pump OH2 Model Selection – Complete API 610 Series Technical Specifications

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Amine Pump OH2 Model Selection – Complete API 610 Series Technical Specifications is a comprehensive guide to heavy-duty, centerline-mounted, radially split centrifugal pumps for amine solutions (MEA/DEA/MDEA/DGA) in natural gas sweetening, refinery tail gas, and acid gas removal, featuring 20 models from 40-250 to 150-400, NACE MR0175 certified materials (316L/2205/Hastelloy), anti‑foaming low‑shear impeller, API 682 Type 22 seals with Plan 53A, and capacity/head ranges up to 550 m³/h and 400 m.

Conatct For Details
DetailReview(0)Additional

1. Product Overview

The OH2 Series Amine Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 12th Edition (ISO 13709) international standards. It is purpose-built for natural gas processing plants, oil refineries, coal chemical plants, and petrochemical facilities, specifically engineered to handle various amine solutions (including MEA, DEA, MDEA, DGA). The media characteristics include viscosity 5–200 mm²/s (ambient), acidic components (H₂S/CO₂) that increase corrosion with concentration, high foaming tendency, and a wide operating temperature range (-10°C to 150°C). It achieves long‑term continuous operation (annual operation rate ≥99.7%) and is a critical equipment for acid gas removal systems such as natural gas sweetening and refinery tail gas treatment.

Model Code Interpretation (OH2):

  • O = Overhung: Impeller outside bearing housing – compact structure, facilitates corrosion‑resistant sealing.

  • H = Horizontal: Horizontal mounting, compatible with amine system layouts.

  • 2 = 2nd Generation: Centerline support design (no rear bracket per API 610 9.1.1.1) – allows axial thermal expansion for amine temperature fluctuations (40–120°C).

Key API 610 Compliance Features:

  • Centerline mounting – compliant with API 610 9.1.1.1.

  • Back pull‑out design (DBSE per API 610 9.1.1.2) – rotor removal without disconnecting piping or motor.

  • Corrosion resistant design – wetted parts selected per NACE MR0175/ISO 15156 to prevent pitting and SCC.

2. Key Structural Features (Amine‑Specific Design)

  • Corrosion Resistant Material System: Wetted parts (casing, impeller) standard 316L stainless steel (Mo ≥2.2%) for conventional amine (H₂S ≤5%). For high‑corrosion service (H₂S >5% or Cl⁻ >1000 ppm), use 2205 duplex steel (yield ≥450 MPa, PREN ≥34). Shaft material 17-4PH precipitation hardening stainless steel, shaft sleeve Hastelloy C-276. Fully compliant with NACE MR0175 sour service.

  • Anti‑Foaming Flow Path Design: Low‑shear, wide‑channel impeller (specific speed n_s = 100–180). CFD‑optimized to minimize turbulence and bubble generation. Surface roughness Ra ≤0.8 μm. Inlet stabilization section and diffuser‑type outlet reduce velocity changes – foam risk minimized, flow/head stability ≥95%.

  • Corrosion‑Resistant Sealing System: Standard API 682 Type 22 double mechanical seals. Friction pairs: silicon carbide (SiC) + tungsten carbide (WC). Seal chamber with FKM O‑rings (amine swell ≤5%). Leakage ≤2 ppm. Supports Plan 53A flush (externally pressurized clean amine) to prevent foam ingress – seal life ≥10,000 hours.

  • Centerline Thermal Stability: Precision cast casing. Shaft runout ≤0.02 mm from -10°C to 150°C, fully compliant with API 610 thermal distortion control. Shaft flexibility index (SFI) per API 610 Appendix K – SFI ≤0.35 to avoid uneven seal face loading and corrosion leakage.

3. General Technical Specifications (Amine‑Specific Parameters)

ParameterValue
Capacity5 – 2,800 m³/h (customizable to 3,000 m³/h) – supports small flow circulation (5–50 m³/h) and large flow sweetening (500–2,800 m³/h)
Head20 – 400 m (max. 1,312 ft) – stable output at 5–200 mm²/s
Operating Temperature-10°C to 150°C (common 40–120°C); high‑temp version to 180°C (Incoloy 825)
Inlet Pressure-0.03 MPa to 0.3 MPa; Outlet Pressure: 0.2–10 MPa (standard 4 MPa, max 10 MPa)
Media Viscosity5 – 200 mm²/s (ambient) – supports high‑concentration MDEA (50%, 150–200 mm²/s)
Motor Power2.2 – 630 kW, efficiency ≥90% – power margin ≥10% for acidic service
Speed50Hz: 1,450/2,900 rpm; 60Hz: 1,750/3,500 rpm
Flange RatingClass 150/300/600# (RF, ASME B16.5)
Material Options316L (standard amine), 2205 duplex (high H₂S/Cl⁻), Hastelloy C‑276 (extreme corrosion), Incoloy 825 (high temp amine)
StandardsAPI 610 12th, GB/T 3215, NACE MR0175/ISO 15156, GB/T 19762

4. Global Equivalent Models (API 610 OH2 for Amine)

BrandSeries / ModelsKey Adaptation
SulzerOHH 40-250, 65-315, 100-400Natural gas sweetening dedicated, 2205 duplex standard, anti‑foaming flow, seal life ≥12,000 h
FlowserveHPX 300, 400, 600Refinery tail gas adapted, Plan 53A flush, suitable for high‑concentration MDEA (200 mm²/s)
KSBKZE 65-200, 80-250Coal chemical desulfurization, H₂S corrosion optimized, NPSHr ≤3.2 m, low‑level tank transfer
NikkisoCZ seriesLeak‑free magnetic drive (API 685) for toxic amine
Shanghai HaiteHT‑OH2 seriesDomestic high‑end alternative, NACE MR0175 certified, fast customization

5. Complete OH2 Amine Pump Model Lineup (20 Core Models by Size)

Small Bore (DN40/DN50 – Small Sweetening Units / Lab)

  • Amine Pump 40-250 OH2 – API 610 OH2, DN40, 250mm impeller, high pressure small flow. Capacity/Head: 25–50 m³/h / 80–110 m. Power: 18.5 kW. Application: Small natural gas sweetening, lab amine circulation.

  • Amine Pump 40-315 OH2 – DN40, 315mm impeller, ultra‑high head. Capacity/Head: 20–45 m³/h / 120–160 m. Power: 22 kW. Application: High‑pressure amine regenerator feed, small tail gas booster.

  • Amine Pump 50-160 OH2 – DN50, 160mm impeller, general small flow. Capacity/Head: 30–60 m³/h / 35–50 m. Power: 11 kW. Application: Small refinery sweetening, amine storage turnover.

  • Amine Pump 50-200 OH2 – DN50, 200mm impeller, standard. Capacity/Head: 30–65 m³/h / 50–70 m. Power: 15 kW. Application: Chemical acid gas removal, amine cooler circulation.

  • Amine Pump 50-250 OH2 – DN50, 250mm impeller, high pressure. Capacity/Head: 30–65 m³/h / 80–115 m. Power: 22 kW. Application: High‑pressure sweetening tower feed, small long‑distance amine transfer.

Medium Bore (DN65/DN80 – Medium Sweetening Units / Centralized Treatment)

  • Amine Pump 65-160 OH2 – DN65, 160mm impeller, medium flow low pressure. Capacity/Head: 50–100 m³/h / 32–48 m. Power: 18.5 kW. Application: Medium gas processing plant, amine circulation main pump.

  • Amine Pump 65-200 OH2 – DN65, 200mm impeller, medium flow general. Capacity/Head: 50–110 m³/h / 48–72 m. Power: 30 kW. Application: Refinery FCC sweetening, amine regenerator feed.

  • Amine Pump 65-250 OH2 – DN65, 250mm impeller, medium flow high pressure. Capacity/Head: 50–110 m³/h / 75–110 m. Power: 45 kW. Application: Long‑distance amine pipeline, high‑pressure sweetening circulation.

  • Amine Pump 65-315 OH2 – DN65, 315mm impeller, medium flow ultra‑high head. Capacity/Head: 45–100 m³/h / 120–160 m. Power: 75 kW. Application: Mountainous gas pipeline sweetening, high‑pressure amine regenerator.

  • Amine Pump 80-160 OH2 – DN80, 160mm impeller, large flow low pressure. Capacity/Head: 80–160 m³/h / 30–48 m. Power: 37 kW. Application: Large refinery tail gas sweetening, amine circulation main pump.

  • Amine Pump 80-200 OH2 – DN80, 200mm impeller, main duty. Capacity/Head: 80–160 m³/h / 48–72 m. Power: 55 kW. Application: Coal chemical desulfurization, amine heat exchanger circulation.

  • Amine Pump 80-250 OH2 – DN80, 250mm impeller, large flow medium‑high pressure. Capacity/Head: 80–160 m³/h / 75–115 m. Power: 90 kW. Application: Long‑distance amine main pipeline, large sweetening tower feed.

  • Amine Pump 80-315 OH2 – DN80, 315mm impeller, large flow high pressure. Capacity/Head: 75–150 m³/h / 120–165 m. Power: 132 kW. Application: Ultra‑high pressure sweetening system, large amine regenerator feed.

Large Bore (DN100/DN125/DN150 – Large Sweetening Plants / Plant‑Wide)

  • Amine Pump 100-200 OH2 – DN100, 200mm impeller, very large flow. Capacity/Head: 120–220 m³/h / 45–70 m. Power: 75 kW. Application: Extra‑large gas processing plant, plant‑wide amine circulation.

  • Amine Pump 100-250 OH2 – DN100, 250mm impeller, very large flow medium pressure. Capacity/Head: 120–220 m³/h / 70–110 m. Power: 160 kW. Application: Cross‑border gas pipeline sweetening, large refining sweetening main pump.

  • Amine Pump 100-315 OH2 – DN100, 315mm impeller, very large flow high pressure. Capacity/Head: 120–220 m³/h / 115–160 m. Power: 250 kW. Application: Ultra‑large coal chemical sweetening, high‑pressure amine circulation.

  • Amine Pump 100-400 OH2 – DN100, 400mm impeller, very large flow ultra‑high head. Capacity/Head: 110–210 m³/h / 180–240 m. Power: 400 kW. Application: Long‑distance amine pipeline network, ultra‑high pressure sweetening tower feed.

  • Amine Pump 125-250 OH2 – DN125, 250mm impeller, giant flow. Capacity/Head: 200–350 m³/h / 65–100 m. Power: 200 kW. Application: National gas sweetening base, million‑ton refinery sweetening main pump.

  • Amine Pump 125-315 OH2 – DN125, 315mm impeller, giant flow high pressure. Capacity/Head: 200–350 m³/h / 110–155 m. Power: 315 kW. Application: Extra‑large gas processing terminal, cross‑border refinery amine transfer.

  • Amine Pump 150-315 OH2 – DN150, 315mm impeller, extra‑large flow. Capacity/Head: 300–550 m³/h / 90–140 m. Power: 450 kW. Application: Global large sweetening project, ultra‑large refining base amine main pump.

  • Amine Pump 150-400 OH2 – DN150, 400mm impeller, top large flow high pressure. Capacity/Head: 300–550 m³/h / 160–220 m. Power: 630 kW. Application: World‑class gas sweetening hub, global top refinery amine pump.

6. Selection Notes (Amine‑Specific)

  • Material matching: Select based on amine type (MEA/DEA/MDEA), H₂S content (≤5% – 316L; >5% – 2205 duplex), Cl⁻ content (>1000 ppm – Hastelloy). Require NACE MR0175 certification.

  • Anti‑foaming margin: Ensure operating point falls within pump high‑efficiency zone (design flow ±10%) to avoid throttling‑induced turbulence. Add foam breaker if necessary.

  • Seal flush plan: Plan 53A for normal service; for high temperature (>120°C) or high concentration amine, use Plan 54 forced cooling flush to prevent seal face fouling.

  • Cavitation control: Higher amine temperature raises vapor pressure – ensure NPSHa ≥ NPSHr + 1.0 m. Lower pump installation height, increase suction pipe diameter.

  • Efficiency monitoring: If long‑term efficiency drops below 80% of design, inspect impeller corrosion/scaling and seal leakage. Clean flow path and replace aged seals.

7. Contact Us

For detailed technical datasheets, model selection assistance (free selection report with amine type, concentration, H₂S/Cl⁻ content, temperature/pressure), 3D models (STEP/IGES), certification documents (API 610, NACE MR0175, material spectral analysis), and customized solutions (high‑H₂S amine, high‑temp amine, leak‑free magnetic drive), please contact: