A circulation pump moves water or other low‑viscosity liquids through a closed or semi‑closed circuit – such as a heating system, chilled water loop, domestic hot water return line, or industrial cooling circuit. Unlike booster pumps that increase pressure from a supply source, circulation pumps overcome the frictional resistance of pipes, fittings, valves, and heat exchangers to keep the fluid moving continuously. They do not typically generate high pressure but maintain steady flow over long distances.
Our circulation pump range covers small wet‑rotor circulators for residential and light commercial heating, up to large horizontal end‑suction and vertical inline pumps for industrial cooling towers, district heating, and process heat transfer. For the most demanding refinery and petrochemical closed‑loop services (e.g., thermal oil or high‑pressure hot water), pumps can be built to API 610 (OH2 / BB3) standards, with 20‑year design life, centreline mounting, and API 682 seals.
The pump is installed in a pipeline and runs continuously or intermittently (controlled by timer or thermostat). It adds energy to the fluid to overcome circulation losses. In a closed loop (e.g., central heating), the same water circulates repeatedly – the pump maintains flow through radiators or fan coil units, then back to the boiler or chiller.
Key differences from a booster pump:
Operates against the system resistance curve, not static head (except for open cooling towers).
Usually handles clean water or water‑glycol mixtures.
Designed for very low NPSH (sufficient pressure is provided by the system expansion tank or tower basin).
| Pump Type | Best For | Key Features |
|---|---|---|
| Wet rotor circulator | Residential & light commercial heating, domestic hot water recirculation | No shaft seal (leak‑free), silent operation, energy‑efficient permanent magnet motor (IE5), compact |
| Vertical inline pump | Commercial HVAC, chilled/hot water, industrial cooling, closed loops | Small footprint, easy pipeline installation, back pull‑out design, flows to 1,500 m³/h |
| Horizontal end‑suction pump | High flow industrial circulation, cooling towers, district heating | Heavy‑duty bearings, wide efficiency range, flows to 2,000 m³/h, API 610 OH2 option |
| Multistage vertical pump | High head, low flow circulation (e.g., high‑rise building hot water) | High pressure in compact size |
| API 610 BB3 axial split | Large industrial closed loops, refinery thermal oil, high‑pressure hot water | 20‑year life, opposed impellers, centreline mounting, up to 150 bar |
| Parameter | Wet Rotor | Vertical Inline | Horizontal End‑Suction | API 610 OH2/BB3 |
|---|---|---|---|---|
| Flow range | 0.5 – 25 m³/h | 10 – 1,500 m³/h | 20 – 2,000 m³/h | Up to 3,000 m³/h |
| Head range | 2 – 12 m | 10 – 80 m | 15 – 100 m | Up to 400 m |
| Pressure rating | 6 – 10 bar | 10 – 16 bar | 10 – 25 bar | Up to 150 bar |
| Temperature | 0 – 110°C | –20 to +140°C | –20 to +150°C | –45 to +400°C |
| Motor power | 0.005 – 0.5 kW | 0.55 – 55 kW | 1.1 – 200 kW | Up to 500 kW |
| Efficiency class | IE5 (permanent magnet) | IE3 / IE4 | IE3 / IE4 | IE3 / IE4 / permanent magnet |
| Material (casing) | Bronze / stainless steel | Cast iron / stainless steel | Cast iron / stainless steel | Carbon steel / 316L SS / duplex |
| Component | Wet Rotor / HVAC | Heavy Industrial | API 610 (Process) |
|---|---|---|---|
| Casing | Bronze, cast iron, or 304 SS | Cast iron epoxy coated or 316 SS | 316L SS (S‑8), duplex (D‑1/D‑2), carbon steel (C‑6) |
| Impeller | Engineering plastic, bronze, or 304 SS | Cast iron, bronze, or 304/316 SS | 316L SS, duplex, 17‑4 PH |
| Shaft | Ceramic or stainless steel | Stainless steel (AISI 304/316) | 4140 hardened, 316 SS, duplex |
| Wear rings | Not fitted (close clearance) | Bronze or cast iron | 316L SS + Stellite |
| Gaskets | EPDM or NBR | EPDM, NBR, or graphite | Spiral wound graphite / PTFE |
For closed loop heating and cooling, standard cast iron or bronze is adequate when using inhibited water or glycol mixtures. For open towers or aggressive water, specify stainless steel.
| Pump Type | Sealing Method | Advantages |
|---|---|---|
| Wet rotor circulator | No mechanical seal – rotor runs in the pumped liquid, separated by a stainless steel can (canned motor) | Zero leakage, maintenance‑free, silent |
| Conventional centrifugal | Mechanical seal (carbon/ceramic or SiC/SiC) | Easy field replacement, lower initial cost |
| API 610 pumps | API 682 cartridge seals (Plan 11, 23, 53B, etc.) | High reliability, zero emissions, suitable for hazardous fluids |
For most HVAC circulation, a mechanical seal is standard and reliable. For domestic hot water recirculation, a wet rotor circulator is preferred because it eliminates seal leaks and noise.
Energy consumption is a major cost for continuous‑duty circulation pumps. We offer:
Wet rotor circulators – Permanent magnet synchronous motor (IE5), automatically adapts to system demand, up to 85% energy saving compared to fixed‑speed pumps.
Standard motors – IE3 efficiency as minimum (mandatory in many regions). IE4/IE5 available for larger pumps.
Variable frequency drive (VFD) – For large circulation pumps, VFD allows flow to follow demand (e.g., variable flow chilled water systems), saving 30‑60% energy.
HVAC (Heating, Ventilation, Air Conditioning)
Hot water heating (radiators, underfloor heating, fan coils)
Chilled water circulation
Condenser water cooling towers
Boiler primary and secondary loops
Domestic / Commercial Hot Water
Hot water recirculation (instant hot water at taps)
Solar thermal system circulation
Heat pump buffer tank circulation
Industrial
Cooling circuit for machinery, welding, plastics, compressors
Process water heating / cooling
Closed loop heat transfer fluid (water‑glycol, thermal oil)
Boiler circulation (high pressure / high temperature)
District Heating & Cooling
Primary network circulation
Building substation secondary pumps
Wide hydraulic coverage – From 0.5 m³/h wet rotor to 2,000 m³/h industrial end‑suction.
High efficiency – IE3/IE4/IE5 motor options; VFD ready.
Quiet operation – Wet rotor circulators are near‑silent; large pumps designed to <85 dB(A).
Corrosion resistance – Bronze, stainless steel, or epoxy‑coated cast iron for long service.
Low NPSH – Particularly important for open cooling towers and boiler feed.
Easy maintenance – Back pull‑out design (all conventional pumps), cartridge seals.
API 610 option – For high‑temperature, high‑pressure, or hazardous fluid closed loops.
Certifications – CE, UL, Energy Efficiency Index (EEI) ≤0.20 for circulators; WRAS/NSF for potable water models.
Wet rotor circulator (e.g., for house heating)
Flow: 0.5 – 2.5 m³/h
Head: 4 – 6 m
Power: 5 – 45 W
Connection: DN25 (1″) or DN32 (1.25″)
Noise: <25 dB
Vertical inline pump (e.g., for commercial building chilled water)
Flow: 50 – 300 m³/h
Head: 20 – 40 m
Power: 5.5 – 30 kW
Flanges: DN80 – DN200
Noise: <70 dB
Horizontal end‑suction (e.g., for industrial cooling)
Flow: 200 – 1,000 m³/h
Head: 15 – 50 m
Power: 22 – 160 kW
Flanges: DN150 – DN350
Closed loop: Install an expansion tank and a fill/pressure maintenance unit. Ensure pump is properly vented.
Open cooling tower: Pump must be below tower basin water level (flooded suction) to prevent cavitation.
Glycol mixtures: Reduce pump performance – consult performance correction charts (viscosity and specific gravity).
Variable flow systems: Use VFD or multiple pump staging; never throttle discharge with a valve on a fixed‑speed pump (wastes energy).
| Task | Frequency |
|---|---|
| Check motor current and vibration | Monthly |
| Inspect mechanical seal for leaks | Quarterly |
| Lubricate bearings (if grease‑fitted) | Every 6 months or per manufacturer |
| Replace seal after 8,000 – 12,000 hours (or when leaking) | As needed |
| Clean strainer (if present) | Annually or when pressure drop increases |
Wet rotor circulators require no maintenance.
| Component | Recommended Quantity |
|---|---|
| Mechanical seal kit | 1 set |
| Bearings (motor side) | 1 set |
| Gasket / O‑ring kit | 1 set |
| Impeller (optional) | 1 |
For selection of the correct Circulation Pump for your HVAC, industrial, or hot water circulation application – including flow and head calculation, system type (closed/open, glycol percentage), material compatibility, motor efficiency requirements, and API 610 option – please contact our engineering team.
Email: info@hyrig.com
Our engineers support residential heating, commercial HVAC, industrial cooling, and process circulation projects worldwide with reliable, energy‑efficient circulation pumps – quiet, durable, and built for continuous duty.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.