A booster pump is a device that increases the pressure of water or other low‑viscosity liquids from a supply source – municipal mains, storage tank, well, or rainwater cistern – to a level adequate for proper operation of fixtures, appliances, irrigation systems, or industrial equipment. Low pressure manifests as weak shower flow, slow-filling washing machines, sprinklers that cannot cover the lawn, or industrial processes that fail to reach required feed pressure.
Our booster pump systems are available as simple single‑pump units (pressure switch + small tank) for homes and small buildings, or as sophisticated multi‑pump variable frequency drive (VFD) skids for commercial towers, hotels, factories, and municipal water distribution. All critical components – pump, motor, controller, pressure sensor, and tank – are available as an integrated package, ready for connection to your water supply.
Pressure switch controlled system (basic):
A pressure switch and small diaphragm tank are connected to the pump discharge.
When a tap opens, pressure drops; the switch activates the pump.
The pump runs, supplying water until pressure reaches cut‑out setting, then stops.
The small tank prevents short cycling and absorbs water hammer.
Variable frequency drive (VFD) system (premium):
A pressure sensor continuously monitors discharge pressure.
The VFD controller adjusts motor speed in real time to maintain a user‑set constant pressure (±0.01 MPa) regardless of flow demand.
When no water is used, the pump ramps down to zero speed and sleeps, restarting instantly when a tap opens.
Energy savings are substantial – typically 30–60% compared to on/off systems.
| Type | Description | Best For |
|---|---|---|
| Single pump with pressure switch | Simple on/off control; small tank included | Small homes, garden, one‑bathroom flats |
| Single pump with VFD (constant pressure) | Speed varies to hold set pressure; no large tank needed | Medium houses, apartments, small commercial buildings |
| Duplex / triplex pump system | Two or three pumps in parallel; VFD control with sequence switching | Hotels, office buildings, factories, irrigation districts |
| Inline booster pump | Compact, direct‑inline design; limited pressure rise | Single tap or appliance boosting |
| Multistage vertical booster | High head, quiet operation, small footprint | Tall buildings, industrial process, reverse osmosis feed |
| Parameter | Residential / Light Commercial | Heavy Commercial / Industrial |
|---|---|---|
| Flow range | 1 – 15 m³/h | 10 – 500 m³/h |
| Head (pressure rise) | 15 – 60 m (1.5 – 6 bar) | 20 – 100 m (2 – 10 bar) |
| Motor power | 0.5 – 5.5 kW (½ – 7.5 HP) | 5.5 – 75 kW (7.5 – 100 HP) |
| Voltage / frequency | 230V single‑phase / 50Hz | 400V three‑phase / 50Hz |
| Liquid temperature | 0 – 40°C (standard) | 0 – 90°C (with mechanical seal upgrade) |
| Maximum operating pressure | 6 – 8 bar | 10 – 16 bar |
| Pump type | Multistage centrifugal or peripheral | Multistage vertical inline or horizontal end‑suction |
| Drive | Pressure switch or built‑in VFD | External VFD or soft starter |
| Material | Stainless steel 304 / cast iron | Stainless steel 316, duplex, or carbon steel |
| Component | Standard (Residential) | Industrial / Aggressive Water |
|---|---|---|
| Pump casing | Stainless steel 304 or cast iron epoxy coated | Stainless steel 316, duplex stainless steel |
| Impeller | Stainless steel 304 or engineering plastic | Stainless steel 316, bronze |
| Shaft | Stainless steel AISI 304 | AISI 316 or duplex |
| Mechanical seal | Carbon / ceramic / NBR | Silicon carbide / silicon carbide / Viton |
| Motor | Aluminium housing, copper windings | Cast iron, IE3/IE4 efficiency, IP55 |
For potable water, all wetted parts are certified to WRAS, NSF/ANSI 61, or local drinking water standards.
| Service | Seal Faces | Elastomer | Suitability |
|---|---|---|---|
| Clean cold water (residential) | Carbon vs. ceramic | NBR (Buna‑N) | Standard, long life |
| Hot water (up to 90°C) | Silicon carbide vs. carbon | Viton (FKM) | High‑temperature resistant |
| Seawater or brackish water | Silicon carbide vs. silicon carbide | Viton or Aflas | Corrosion resistant, hard faces |
| Abrasive water (sand) | Tungsten carbide vs. tungsten carbide | Viton | Extreme wear resistance |
Multistage vertical inline pump – The most common for building booster systems. Compact, quiet, efficient, and able to generate high pressure in a small footprint.
Horizontal end‑suction pump – For higher flow rates (above 50 m³/h) in industrial and large commercial applications. Often paired with VFD and used in duplex configuration.
Peripheral / regenerative turbine pump – For low flow, high head boosting (e.g., single house with deep well or high roof). Very low noise, excellent for domestic use.
Self‑priming booster pump – For installations where the pump must be above the water level (e.g., pumping from a storage tank at grade). Includes a priming chamber.
A VFD booster pump offers:
Constant pressure – No pressure drop when a second tap opens. The pump speeds up instantly to maintain set pressure.
Energy savings – A typical house with 4 people saves 30‑50% electricity vs. a pressure switch system because the pump runs slower most of the time.
Soft start – No current spikes, prolonging motor and pump life.
Silent operation – At low flow (e.g., trickle fill), the pump runs at very low RPM – nearly inaudible.
Sleep mode – When no flow, the pump stops entirely until a tap is opened.
Protection – Built‑in dry run, over‑current, over‑voltage, and water leak detection.
For buildings with more than 3‑4 fixtures or for anyone serious about water comfort, a VFD booster pump is the correct choice.
| Sector | Application |
|---|---|
| Residential | Single‑family home, apartment, duplex, small housing complex |
| Commercial | Hotels, hospitals, schools, office buildings, shopping malls |
| Irrigation | Lawn sprinklers, golf courses, greenhouse misting, drip irrigation |
| Industrial | Process water feed, cooling tower make‑up, reverse osmosis pre‑treatment, boiler feed, wash‑down stations |
| Municipal | Small water distribution zones, pressure zones in hilly areas |
| Agriculture | Livestock watering, crop irrigation, tank filling |
Constant, stable pressure – No more shower pressure fluctuations when someone opens a tap.
Energy efficient – VFD models cut electricity bills significantly.
Low noise – Multistage vertical pumps are naturally quiet; VFD operation at low speed is nearly silent.
Corrosion resistant – Stainless steel construction for long life with potable water.
Complete system package – Pump, motor, VFD (or pressure switch), pressure sensor, small tank, and interconnecting pipework – ready to install.
Compact footprint – Vertical multistage design requires minimal floor space.
Easy maintenance – Back pull‑out or cartridge design; cartridge mechanical seal replacement without removing motor.
Global voltage and certification – CE, UL, ETL, WRAS, NSF available.
Warranty – 2 years (3 years on VFD model with registration).
Determine required flow and pressure – Based on number of fixtures, peak simultaneous demand, and required pressure at the furthest outlet.
Select pump size – Use pump selection software or consult our engineers.
Installation location – Dry, ventilated, frost‑free room. Noise‑sensitive areas should use VFD model for quiet operation.
Piping – Use properly sized pipe (not smaller than pump ports). Install isolation valves and check valve on discharge.
Electrical – Dedicated circuit with appropriate breaker. VFD requires clean power (no generator without filtering).
Programming – Set desired constant pressure (typically 3.0‑4.5 bar for houses, 4.5‑6.0 bar for commercial buildings).
| Task | Frequency | Notes |
|---|---|---|
| Check pressure pre‑charge in tank (if fitted) | Every 6 months | Empty system, check air pressure (2.0‑2.5 bar typical) |
| Clean strainer (if fitted) | 3‑6 months | Depending on water cleanliness |
| Inspect for leaks | Monthly | – |
| Mechanical seal replacement | 5‑10 years (when dripping) | Use OEM kit |
| VFD firmware updates | As recommended | For advanced models |
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump runs but no pressure | No water in suction line, air leak, foot valve stuck | Check priming; inspect suction pipe joints; clean foot valve |
| Pump cycles on/off rapidly | Pressure tank waterlogged, leak in system | Drain tank and re‑pressurise; fix leaks |
| Low pressure (VFD model) | Speed limited, sensor error, pump worn | Check VFD settings; clean or replace pressure sensor; check impeller |
| Overheating | Run dry, blocked cooling fan, high ambient temperature | Ensure water supply; clean fan; improve ventilation |
| VFD fault code | Varies (overvoltage, undervoltage, motor overload) | Refer to VFD manual; check supply voltage; reduce load |
| Component | Recommended Quantity |
|---|---|
| Mechanical seal kit | 1 set |
| Pressure sensor (for VFD model) | 1 |
| Pressure switch (for basic model) | 1 |
| Small diaphragm tank (2‑8 L) | 1 |
| Motor fan (if replaceable) | 1 |
For detailed selection of the correct Booster Pump system – including flow and head calculation, number of fixtures, peak demand analysis, pump type (single‑speed vs. VFD), and complete system configuration – please contact our engineering team.
Email: info@hyrig.com
Our engineers support residential, commercial, and industrial water boosting projects worldwide with reliable, energy‑efficient booster pump systems – from single‑family homes to high‑rise buildings and factories.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.